Retinal Arteriole Pulse Waveform Analysis Using a Fully-Automated Doppler Optical Coherence Tomography Flowmeter: a Pilot Study

被引:7
|
作者
Sakai, Jun [1 ]
Minamide, Kana J. [1 ]
Nakamura, Syunsuke [1 ]
Song, Young-Seok [2 ]
Tani, Tomofumi [2 ]
Yoshida, Akitoshi [2 ]
Akiba, Masahiro [1 ]
机构
[1] Topcon Corp, Res & Dev Div, Tokyo, Japan
[2] Asahikawa Med Univ, Dept Ophthalmol, Asahikawa, Hokkaido, Japan
来源
关键词
optical coherence tomography; blood flow; pulse waveform; retinal artery; Doppler OCT; BLOOD-FLOW MEASUREMENT; CIRCULATION; INDEX;
D O I
10.1167/tvst.8.3.13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the repeatability and reproducibility of the measurement of retinal arteriole pulse waveforms using a novel fully-automated Doppler optical coherence tomography (DOCT) flowmeter in healthy subjects. Methods: Twenty eyes of 20 healthy subjects were included to test the intrasession repeatability of pulse waveform analysis. DOCT measurements were performed based on a newly developed instantaneous Doppler angle measurement method. Upstroke time (UT), which is the time from the minimum to the maximum retinal blood velocity, and the resistance index (RI) of the retinal arteriole pulse waveform were measured. Coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) were calculated. Interdevice reproducibility between two instruments was assessed in five eyes of five subjects. Results: The mean UT was 130.3 ms (range, 110.1-152.1 ms), and the mean RI was 0.66 (range, 0.51-0.82). The respective ICCs of UT and the RI for the intrasession repeatability of assessment were 0.87 and 0.78. The respective CVs of UT and the RI were 6.6 +/- 3.3% and 4.7 +/- 2.1%. Regarding interdevice reproducibility, there were no significant differences between the measurements derived from the instruments (P > 0.05). Conclusions: Pulse waveform measurement in retinal arterioles using a fully-automated DOCT flowmeter exhibited good repeatability and interdevice reproducibility. Translational Relevance: The above-described improved DOCT flowmeter system provides reasonably repeatable measurements of retinal arteriole pulse waveforms, potentially facilitating systemic-circulation abnormality monitoring. The examination of the circulation with the novel device can be potentially useful for evaluating systemic circulation.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Automated retinal boundary segmentation of optical coherence tomography images using an improved Canny operator
    Jian Liu
    Shixin Yan
    Nan Lu
    Dongni Yang
    Hongyu Lv
    Shuanglian Wang
    Xin Zhu
    Yuqian Zhao
    Yi Wang
    Zhenhe Ma
    Yao Yu
    Scientific Reports, 12
  • [42] Automated segmentation of retinal layers from optical coherence tomography images using geodesic distance
    Duan, Jinming
    Tench, Christopher
    Gottlob, Irene
    Proudlock, Frank
    Bai, Li
    PATTERN RECOGNITION, 2017, 72 : 158 - 175
  • [43] Study of flow dynamics in complex vessels using Doppler optical coherence tomography
    Bonesi, M.
    Churmakov, D.
    Meglinski, I.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (11) : 3279 - 3286
  • [44] Analysis of Choroidal and Retinal Vasculature in Inherited Retinal Degenerations Using Optical Coherence Tomography Angiography
    de Carlo, Talisa E.
    Adhi, Mehreen
    Salz, David A.
    Joseph, Tony
    Waheed, Nadia K.
    Seddon, Johanna M.
    Duker, Jay S.
    Reichel, Elias
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (02): : 120 - 127
  • [45] Relationship between Visual Field Sensitivity and Retinal Blood Flow Measurements by Doppler Optical Coherence Tomography Flowmeter in Primary Open Angle Glaucoma
    Yoshioka, Takafumi
    Song, Youngseok
    Takahashi, Kengo
    Tani, Tomofumi
    Akiba, Masahiro
    Sakai, Jun
    Nakamura, Syunsuke
    Minamide, Kana
    Ishiko, Satoshi
    Yanagi, Yasuo
    Yoshida, Akitoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [46] Pilot Study of Optical Coherence Tomography Measurements of Retinal Vessel Relief Height in the Detection of Glaucoma
    Tan, Ou
    Tehrani, Shandiz
    Orozco, Brandon V.
    Wang, Xiaogang
    Jia, Yali
    Kraus, Martin F.
    Fujimoto, James G.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] Quantitative analysis of retinal perfusion in mice using optical coherence tomography angiography
    Alnawaiseh, Maged
    Brand, Cristin
    Bormann, Eike
    Wistuba, Joachim
    Eter, Nicole
    Heiduschka, Peter
    EXPERIMENTAL EYE RESEARCH, 2017, 164 : 151 - 156
  • [48] ReLayNet: retinal layer and fluid segmentation of macular optical coherence tomography using fully convolutional networks
    Roy, Abhijit Guha
    Conjeti, Sailesh
    Karri, Sri Phani Krishna
    Sheet, Debdoot
    Katouzian, Amin
    Wachinger, Christian
    Navab, Nassir
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (08): : 3627 - 3642
  • [49] Reply to comments on "A pilot study assessing retinal pathology in psychosis using optical coherence tomography: Choroidal and macular thickness"
    Ahmad, Meleha
    Joe, Peter
    Smith, Roland Theodore
    Malaspina, Dolores
    PSYCHIATRY RESEARCH, 2019, 279 : 367 - 367
  • [50] Pilot study for neurological and retinal imaging as biomarkers for Parkinson's disease using optical coherence tomography-angiography
    Berkowitz, Sean
    Patel, Shriji