Dynamic fracture evolution of tight sandstone under uniaxial compression in high resolution 3D X-ray microscopy

被引:26
|
作者
Zhang, Yifei [1 ,2 ,3 ]
Niu, Suyun [1 ,2 ]
Du, Zhongming [1 ,2 ]
Hao, Jin [1 ,2 ]
Yang, Jijin [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Shale Gas & Geoengn, Beijing 100029, Peoples R China
[2] Chinese Acad Sci, Innovat Acad Earth Sci, Beijing 100029, Peoples R China
[3] Univ Chinese Acad Sci, Coll Earth & Planetary Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Tight sandstone; 3D XRM; Uniaxial compression; Fracture evolution; COMPUTED-TOMOGRAPHY; CRACK-PROPAGATION; ACOUSTIC-EMISSION; BRITTLE-FRACTURE; STRESS; ROCK; DAMAGE; DEEP; RESERVOIR; STRENGTH;
D O I
10.1016/j.petrol.2020.107585
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Stress-induced fracture evolution in tight sandstone reservoir is of great significance in hydraulic fracturing treatment and borehole stability. The meso scale fracture mechanism needs to be well understood. In this work, the smaller-sized tight sandstone specimens (4 mm in diameter and 8 mm in height) from Bashijiqike formation were studied under uniaxial compression in high resolution three dimensional (3D) X-ray microscopy (XRM). Using high-resolution XRM, 2D slices and 3D digital cores with real pore structure characteristics were reconstructed at different stages of uniaxial compression. During the uniaxial loading process, porosity and diameter distribution of the voids were obtained to analyze the progressive deformation of rock, and then the complexity and heterogeneity of the cracks were quantified by applying fractal analysis. The results show that the fracture evolution of tight sandstone at meso scale could be divided into compaction stage, linear elastic behavior stage, non-linear deformation stage and residual deformation stage. The mineral composition and meso structure of tight sandstone have significant effects to its mechanical properties, fracture pattern and crack morphology under uniaxial compression. The propagation direction of secondary cracks tends to parallel to the direction of axial stress, revealed by higher resolution of region of interest (ROI) imaging.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [31] High-resolution 3D imaging of integrated circuits by X-ray ptychography
    Odstrcil, Michal
    Holler, Mirko
    Raabe, Jorg
    Guizar-Sicairos, Manuel
    IMAGE SENSING TECHNOLOGIES: MATERIALS, DEVICES, SYSTEMS, AND APPLICATIONS V, 2018, 10656
  • [32] High-resolution 3D X-ray imaging of intracranial nitinol stents
    Rudolph M. Snoeren
    Michael Söderman
    Johannes N. Kroon
    Ruben B. Roijers
    Peter H. N. de With
    Drazenko Babic
    Neuroradiology, 2012, 54 : 155 - 162
  • [33] High resolution bone imaging using 3D rotational X-ray imaging
    Grass, M
    Koppe, R
    Klotz, E
    de Beek, JO
    Aerts, H
    Kemkers, R
    Rasche, V
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 531 - 536
  • [34] Data-fusion of high resolution X-ray CT, SEM and EDS for 3D and pseudo-3D chemical and structural characterization of sandstone
    De Boever, Wesley
    Derluyn, Hannelore
    Van Loo, Denis
    Van Hoorebeke, Luc
    Cnudde, Veerle
    MICRON, 2015, 74 : 15 - 21
  • [35] High-resolution 3D X-ray imaging of intracranial nitinol stents
    Snoeren, Rudolph M.
    Soderman, Michael
    Kroon, Johannes N.
    Roijers, Ruben B.
    de With, Peter H. N.
    Babic, Drazenko
    NEURORADIOLOGY, 2012, 54 (02) : 155 - 162
  • [36] 3D image visualization of meso-structural changes in a bimsoil under uniaxial compression using X-ray computed tomography (CT)
    Wang, Y.
    Li, C. H.
    Hu, Y. Z.
    ENGINEERING GEOLOGY, 2019, 248 : 61 - 69
  • [37] Deformation microstructure under nanoindentations in Cu using 3D x-ray structural microscopy
    Yang, WG
    Larson, BC
    Pharr, GM
    Ice, GE
    Swadener, JG
    Budai, JD
    Tischler, JZ
    Liu, WJ
    SURFACE ENGINEERING 2002-SYNTHESIS, CHARACTERIZATION AND APPLICATIONS, 2003, 750 : 113 - 118
  • [38] Metrology of 3D IC with X-ray Microscopy and Nano-scale X-ray CT
    Wang, Steve
    Gelb, Jeff
    Lau, S. H.
    Yun, Wenbing
    PROCEEDINGS OF THE 2009 IEEE INTERNATIONAL INTERCONNECT TECHNOLOGY CONFERENCE, 2009, : 131 - 133
  • [39] X-ray microscopy reveals nano-resolution 3D structure of mouse brain tissue
    Mizutani, Haruo
    Sagara, Hiroshi
    Takeuchi, Akihisa
    Uesugi, Kentaro
    Ohigashi, Takuji
    Suzuki, Yoshio
    Ejima, Takeo
    Takagi, Toshihisa
    NEUROSCIENCE RESEARCH, 2011, 71 : E308 - E308
  • [40] Fracture evolution characteristics of sandstone containing double fissures and a single circular hole under uniaxial compression
    Chen Minliang
    Jing Hongwen
    Ma Xiujun
    Su Haijian
    Du Mingrui
    Zhu Tantan
    International Journal of Mining Science and Technology, 2017, 27 (03) : 499 - 505