Design optimization of Steel Anchor beam in Cable-pylon Composite Anchor Structure

被引:1
|
作者
Zhao, Min [1 ]
Lu, Wenru [1 ]
Ma, Lin [2 ]
机构
[1] Changan Univ, Xian 710064, Peoples R China
[2] Tianjin municipal engineering design& res, Tianjin, Peoples R China
关键词
bridge engineering; cable stayed bridge; cable-pylon composite anchor structure; steel anchor beam; design optimization;
D O I
10.4028/www.scientific.net/AMM.501-504.1374
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Because the stress concentration usually appears in the plate corner or discontinuity zone, it is necessary to optimize design for local plate of steel anchor beam bearing huge cable force. Based on 3D elaborate finite-element method, the stress distribution of steel anchor beam of cable-pylon composite anchor structure was analyzed. The results showed that the steel anchor beam of cable-pylon composite anchorage structure was safe and reliable, the application of the vertical stiffened plate of the side plate in anchor box and the middle diaphragm efficiently improved the force state of the steel anchor beam, on the other hand the stress conditions of the concrete pylon was more ideal when the steel anchor beam was within the boundary condition of one end of anchor beam fixed and the other end with sliding support.
引用
收藏
页码:1374 / +
页数:2
相关论文
共 50 条
  • [21] Mechanical property of cable-pylon anchorage zone of cable-stayed bridge with steel box girder
    School of Highway, Chang'an University, Xi'an 710064, China
    不详
    不详
    Zongguo Gonglu Xuebao, 2007, 4 (48-52):
  • [22] Analysis of steel anchor beam structural system of anchorage in pylon of Jingyue Changjiang River Highway Bridge
    Hubei Provincial Transport Planning and Design Institute, Wuhan
    430051, China
    不详
    430034, China
    Bridge Constr., 2 (89-93):
  • [23] Analysis and design of the tower pier anchor of steel tower cable stayed bridge
    Sun, Dong-li
    Xie, Bin
    Liu, Xu kai
    Cao, Jing
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND TRANSPORTATION 2015, 2016, 30 : 1171 - 1175
  • [24] Design study and fatigue test of cable-to-girder anchorage structure of double tensile anchor plates and anchor box
    Zeng, Yong-Ping
    Chen, Ke-Jian
    Yuan, Ming
    Chen, Si-Xiao
    Dai, Sheng-Yong
    Bridge Construction, 2013, 43 (06) : 45 - 50
  • [25] Stability analysis of slopes reinforced with anchor cables and optimal design of anchor cable parameters
    Deng, Dong-Ping
    Li, Liang
    Zhao, Lian-Heng
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2021, 25 (13) : 2425 - 2440
  • [26] Spatial Mechanical Behavior Research of Cable-pylon Anchorage Zone of Steel Box Concrete Tower
    Dang, Dong
    He, Shuan Hai
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 1466 - 1473
  • [27] Analysis of force mechanism of pylon anchorage structure of fixed-end steel anchor box type
    Department of Bridge Engineering, Tongji University, Shanghai
    200092, China
    Bridge Constr., 1 (33-38):
  • [28] A New Prestress Loss Calculation Model of Anchor Cable in Pile-Anchor Structure
    Gao, Xing
    Jia, Jinqing
    Mei, Guoxiong
    Bao, Xiaohua
    Zhang, Lihua
    Liao, Xiaoping
    MATHEMATICS, 2022, 10 (08)
  • [29] ON THE OPTIMAL STRUT-AND-TIE MODELS AND DESIGN APPROACH FOR THE CABLE-PYLON ANCHORAGE ZONE
    Cui, Nannan
    Huang, Shiping
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2019, 25 (06) : 576 - 586
  • [30] Failure Analysis of Deep Composite Roof Roadway and Support Optimization of Anchor Cable Parameters
    Li, Chen
    Zhang, Wenlong
    Huo, Tianhong
    Yu, Rui
    Zhao, Xidong
    Luo, Ming
    GEOFLUIDS, 2021, 2021