Development of a 50 MHz Linear Array for Endoscopic Imaging

被引:0
|
作者
Roa, Carlos-Felipe [1 ,2 ]
Caminiti, Jacqueline [2 ]
Yin, Jianhua [2 ]
Boyes, Aaron [2 ]
Cherin, Emmanuel [2 ]
Singh, Nidhi [1 ,2 ]
Foster, F. Stuart [1 ,2 ]
Demore, Christine E. M. [1 ,2 ]
机构
[1] Univ Toronto, Toronto, ON, Canada
[2] Sunnybrook Res Inst, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ultrasound imaging; high frequency; piezoelectric transducers; linear arrays; laser micromachining; miniaturization; ULTRASOUND;
D O I
10.1109/IUS54386.2022.9957151
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Endoscopic micro-ultrasound can potentially improve imaging of diseased tissue structure and function if the probe can be positioned near the tissue of interest. We previously reported the fabrication of miniaturized linear arrays using thin, high-density flexible printed circuit boards (FPCBs) connected to array elements with laser patterned deposited metals. Here we extend previous work to limit the area used for electrical connection to array elements and place element signal electrodes on the back surface of the array so the ground electrode can be at the front face and we use extended electroplated signal electrodes to create bond-pads at the edges to achieve an endoscopic form factor. We demonstrate fabrication with a forward-viewing, 50 MHz, 64-element linear array that fits within a 3-mm-diameter lumen. The array was 2.5 mm (azimuth) by 1.6 mm (elevation), had a mean resonant frequency of 48.2 MHz and a mean kt of 0.41. Laser Doppler vibrometry measurements allow further investigation of the device performance. Phantom images are shown to demonstrate array capability.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Development of a Small-Footprint 50 MHz Linear Array: Fabrication and Micro-Ultrasound Imaging Demonstration
    Roa, Carlos-Felipe
    Cherin, Emmanuel
    Singh, Nidhi
    Yin, Jianhua
    Boyes, Aaron
    Foster, F. Stuart
    Demore, Christine E. M.
    SENSORS, 2024, 24 (06)
  • [2] A 35 MHz linear array for medical imaging
    Cannata, JM
    Ritter, TA
    Shung, KK
    MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 : 120 - 126
  • [3] A 35 MHz linear array for medical imaging
    Cannata, JM
    Ritter, TA
    Shung, KK
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1157 - 1160
  • [4] A 35 MHz linear ultrasonic array for medical imaging
    Cannata, JM
    Shrout, TR
    Shung, KK
    ISAF 2002: PROCEEDINGS OF THE 13TH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, 2002, : 343 - 346
  • [5] Performance of a 50 MHz annular array based imaging system
    Brown, JA
    Morton-Démoré, C
    Foster, FS
    Lockwood, GR
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 760 - 763
  • [6] Theoretical evaluation of a 50 MHz split aperture linear phased array
    Talman, JR
    Lockwood, GR
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1675 - 1678
  • [7] Development and clinical evaluation of a 10MHz ultrasound linear array catheter for endobronchial imaging
    Cladé, O
    Tranquart, F
    Palanchon, P
    Bleuzen, A
    Diot, P
    Dinet, D
    Dufait, R
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 653 - 656
  • [8] 10MHz ultrasound linear array catheter for endobronchial imaging
    Cladé, O
    Tranquart, F
    Olar, M
    Hazouard, E
    Dinet, D
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1942 - 1945
  • [9] Development of a high frequency (35-MHz) linear ultrasonic array
    Cannata, JM
    Shung, KK
    MEDICAL IMAGING 2004: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2004, 5373 : 18 - 23
  • [10] Compact linear array at 810 MHz
    Sabatier, C
    Brachat, P
    Calderone, A
    Seguenot, E
    Devillers, F
    IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM 1997, VOLS 1-4, 1997, : 2119 - 2120