Characterizing coronary motion and its effect on MR coronary angiography - Initial experience

被引:5
|
作者
Al-Kwifi, Osama [1 ]
Stainsby, Jeffrey [1 ]
Foltz, Warren D. [1 ]
Sussman, Marshall S. [1 ]
Huang, Yuexi [1 ]
Wright, Graham A. [1 ]
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Med Imaging Res, Imaging Res Program, Toronto, ON M4N 3M5, Canada
关键词
coronary MR angiography; coronary artery motion; magnetic resonance angiography; spiral acquisition; point-spread function;
D O I
10.1002/jmri.20697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize coronary artery motion as a prescan procedure to select the optimum scan setting that will produce high-resolution images. Materials and Methods: A 2D real-time scan was used to image the major coronary arteries during breath-holding and free-breathing conditions. With the use of the 2D images, motion displacement of each artery was measured along three axes. Motion data obtained from a computer simulation were used to estimate point-spread functions (PSFs) associated with different high-resolution spiral acquisition strategies, including real-time, cardiac-gated, and respiratory-gated acquisitions. The simulation output determined the optimum acquisition and scan parameters that would produce the highest-spatial-resolution images of the coronary arteries. The effects of heart rate (HR), extended breath-holding, and number of slices per heart cycle were also investigated. Results: Substantial variations in coronary motion occur among individuals, which directly influences the optimum parameters for a high-resolution scan. Lower HRs and longer breath-holds yield substantially increased spatial resolution. The maximum number of slices per heart cycle can also be determined to minimize slice-to-slice distortion. Conclusion: The results suggest that to obtain high-resolution coronary images, one should perform a prescan coronary-motion characterization for each individual so that the scan parameters can be optimized before data acquisition.
引用
收藏
页码:842 / 850
页数:9
相关论文
共 50 条
  • [41] 3D MR coronary angiography vs selective coronary angiography-impact of the novel motion adapted gating technique
    Weber, C
    Steiner, P
    Sinkus, R
    Dill, T
    Boernert, P
    Buecheler, E
    RADIOLOGY, 2000, 217 : 285 - 285
  • [42] Coronary MR Angiography in patients with coronary artery disease using image-based respiratory motion compensation
    Markus Henningsson
    Konstantinos Bratis
    Eike Nagel
    Rene Botnar
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [43] Coronary CT angiography and MR angiography of Kawasaki disease
    Goo, HW
    Park, IS
    Ko, JK
    Kim, YH
    PEDIATRIC RADIOLOGY, 2006, 36 (07) : 697 - 705
  • [44] Coronary CT angiography and MR angiography of Kawasaki disease
    Hyun Woo Goo
    In-Sook Park
    Jae Kon Ko
    Young Hwee Kim
    Pediatric Radiology, 2006, 36 : 697 - 705
  • [45] Intraindividual comparison of 3D coronary MR angiography and coronary CT angiography
    Ozgun, Murat
    Rink, Michael
    Hoffmeier, Andreas
    Botnar, Rene M.
    Heindel, Walter
    Fischbach, Roman
    Maintz, David
    ACADEMIC RADIOLOGY, 2007, 14 (08) : 910 - 916
  • [46] Comparison of diagnostic performance of MR coronary angiography with ct coronary angiography in patients with >50% coronary artery stenosis and assess its diagnostic accuracy
    Leng, Michael L. C.
    CIRCULATION, 2012, 125 (19) : E683 - E684
  • [47] Patients experience from CT coronary angiography versus conventional coronary angiography
    Diederichsen, A.
    Petersen, H.
    Johansen, A.
    Sandgaard, N.
    Hoilund-Carlsen, P. F.
    Mickley, Hans Frederik H. F.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S38 - S38
  • [48] 126 Comparison of coronary MR and CT angiography in detection of coronary stenosis with coronary calcification
    Xin Liu
    Christopher Francois
    David Tuite
    Debiao Li
    James Carr
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [49] Free-breathing black-blood coronary MR angiography: Initial results
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Manning, WJ
    RADIOLOGY, 2001, 219 (01) : 278 - 283
  • [50] Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography
    Dewan, Maneesh
    Hager, Gregory D.
    Lorenz, Christine H.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 604 - 615