Mean deviation of inter-rater scoring (MDIS): a simple tool for introducing conformity into groups of clinical investigators

被引:2
|
作者
Bourin, M
Deplanque, D
Zins-Ritter, M
机构
[1] Soc Nantaise Psychiat Biol, Nantes, France
[2] Univ Nantes, Nantes, France
[3] Univ Lille 2, Dept Pharmacol, Lille, France
关键词
clinical trials; inter-rater reliability; investigator training; videotape;
D O I
10.1097/01.yic.0000122858.35081.9b
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In spite of considerable progress over the past decade, training investigators for inter-rater reliability for clinical trials remains a major problem. The aim of the present study was to promote a new tool to increase data homogeneity by introducing conformity into groups of clinical investigators. The investigators' scoring grid we are proposing-the Mean Deviation of Inter-rater Scoring (MDIS)-involves the calculation of the score deviation for each investigator relative to the median score of an expert group who had evaluated the same videotape-recorded clinical case. Whatever the scale, the score deviation is calculated as the absolute deviation value from the median score obtained by the experts for each item. The MDIS value is then evaluated from all the scores given by an investigator by dividing the total sum of the previously defined values by the number of items of the scale. Some examples from practice are given using several rating scales: (i) Hamilton Anxiety Rating Scale; (ii) Hamilton Depression Rating Scale; (iii) Montgomery Asberg Depression Rating Scale; and (iv) Positive And Negative Symptoms Scale. Finally, such a method could also be employed by experts to evaluate the quality of videotape-recorded clinical cases used in clinical trials, as well as by teachers to evaluate initial or continuous medical training. (C) 2004 Lippincott Williams Wilkins.
引用
下载
收藏
页码:209 / 213
页数:5
相关论文
共 14 条
  • [11] Inter-Rater Reliability for the Pragmatic Evaluation of Point of Care Lung Ultrasound for the Triage of COVID-19 Patients Using a Simple Scoring Matrix
    Tran, Timothy T.
    Wilson, Juliana
    Riscinti, Mathew
    Fuchita, Mikita
    Kendall, John
    Ng, Patrick
    Fernandez-Bustamante, Ana
    ANESTHESIA AND ANALGESIA, 2022, 134 : 211 - 212
  • [12] Inter-rater reliability of the Modified Modified Ashworth Scale as a clinical tool in measurements of post-stroke elbow flexor spasticity
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Mousakhani, Atefeh
    Nouriyan, Azam
    Omidvar, Zeinab
    NEUROREHABILITATION, 2009, 24 (03) : 225 - 229
  • [13] Ocular Motor Score (OMS): a clinical tool to evaluating ocular motor functions in children. Intrarater and inter-rater agreement
    Olsson, Monica
    Fahnehjelm, Kristina Tear
    Rydberg, Agneta
    Ygge, Jan
    ACTA OPHTHALMOLOGICA, 2015, 93 (05) : 444 - 449
  • [14] Assessment of medical student clinical reasoning by "lay" vs physician raters: inter-rater reliability using a scoring guide in a multidisciplinary objective structured clinical examination
    Berger, Alexandra J.
    Gillespie, Colleen C.
    Tewksbury, Linda R.
    Overstreet, Ivey M.
    Tsai, Ming C.
    Kalet, Adina L.
    Ogilvie, Jennifer B.
    AMERICAN JOURNAL OF SURGERY, 2012, 203 (01): : 81 - 86