A simple method to calculate the volume of shipworm tunnels from radiographs

被引:2
|
作者
Guarneri, Irene [1 ]
Sigovini, Marco [1 ]
Tagliapietra, Davide [1 ]
机构
[1] Natl Res Council Italy, Marine Sci Inst CNR ISMAR, Arsenale Tesa 104,Castello 2737-F, I-30122 Venice, Italy
关键词
Bioerosion; Shipworm; Marine woodborer; EN; 275; Image analysis; Radiograph; GROWTH; TEREDO; BIVALVIA; TEREDINIDAE;
D O I
10.1016/j.ibiod.2020.105109
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Shipworms (Bivalvia: Teredinidae) are considered one of the main agents of wood bioerosion in the marine environment. They dig tunnels inside the wood they feed on, causing its progressive weakening. X-rays are a widely used non-destructive technique to assess wood biodeterioration (e.g. EN 275). However, an X-ray is a two-dimensional projection, with the possibility that some of the objects overlap and obfuscate each other. The higher the density of the shipworms, the more difficult is to count and measure the single tunnel. The aim of this work was to find a straight-forward method for calculating the volume of shipworm tunnels based on the size of shipworm shells, which are always clearly identifiable on the X-rays. Some wood test panels attacked by shipworms were analysed, with two distinct geometric methods being applied to estimate the tunnels volume based on radiographs. An allometric model was then introduced linking the volume to the shell diameter, which allows an easy estimation of the actual bioeroded volume from conventional two-dimensional radiographs. This technique allows to evaluate the bioerosion after the first growing season, shortening the exposure time and reducing costs. The model can be applied even when the tunnels are difficult to distinguish from each other, i.e. overlapped, folded or covering the whole surface of the radiograph.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A SIMPLE METHOD TO CALCULATE INTERNATIONAL SENSITIVITY INDEX (ISI)
    TABERNER, DA
    DUFTY, JMK
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1240 - 1240
  • [22] SIMPLE METHOD TO CALCULATE THE SURGICALLY INDUCED REFRACTIVE CHANGE
    OLSEN, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (02): : 319 - 319
  • [24] A SIMPLE METHOD TO CALCULATE THE CELL-LOSS FACTOR
    KNOLLE, H
    CELL AND TISSUE KINETICS, 1984, 17 (03): : 311 - 312
  • [25] A SIMPLE METHOD OF STANDARDIZING THE MEASUREMENT OF LINEAR DISTANCES AND OBJECT SIZE FROM CHEST RADIOGRAPHS
    BUSH, A
    DENISON, DM
    CLINICAL SCIENCE, 1987, 72 : P53 - P54
  • [26] SIMPLE METHOD FOR PRODUCTION OF SLIDES OF CT IMAGES FROM MULTI-FORMAT RADIOGRAPHS
    KUHNS, LR
    SEIGEL, R
    BORLAZA, GS
    COMPUTERIZED TOMOGRAPHY, 1978, 2 (01): : 45 - 46
  • [27] Evaluation of a novel method to calculate cementless femoral stem level on craniocaudal projection radiographs
    Brand, Kenneth J.
    Beale, Brian S.
    Hudson, Caleb C.
    VETERINARY SURGERY, 2021, 50 (08) : 1592 - 1599
  • [28] A SIMPLE TECHNIQUE FOR REPRODUCTION OF SLIDES FROM RADIOGRAPHS
    BEZIAT, J
    CROS, P
    FREIDEL, M
    DUMAS, P
    REVUE DE STOMATOLOGIE ET DE CHIRURGIE MAXILLO-FACIALE, 1984, 85 (01): : 74 - 76
  • [29] A simple method to estimate renal volume from computed tomography
    Breau, Rodney H.
    Clark, Edward
    Bruner, Bryan
    Cervini, Patrick
    Atwell, Thomas
    Knoll, Greg
    Leibovich, Bradley C.
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2013, 7 (5-6): : 189 - 192
  • [30] Simple Method to Calculate the Force between Thin Walled Solenoids
    Perez-Loya, J. Jose
    Lundin, Urban
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2016, 51 : 93 - 100