Quantitative evaluation of atrial radio frequency ablation using intracardiac shear-wave elastography

被引:20
|
作者
Kwiecinski, Wojciech [1 ]
Provost, Jean [1 ]
Dubois, Remi [2 ]
Sacher, Frederic [2 ]
Haissaguerre, Michel [1 ,2 ]
Legros, Mathieu [1 ,3 ]
An Nguyen-Dinh [3 ]
Dufait, Remi [3 ]
Tanter, Mickael [1 ]
Pernot, Mathieu [1 ]
机构
[1] CNRS, Inst Langevin ESPCI ParisTech, UMR7587, INSERM,U797, F-75005 Paris, France
[2] Univ Bordeaux, INSERM 1045, LIRYC Inst, F-33400 Bordeaux, France
[3] Vermon, F-37000 Tours, France
关键词
shear-wave elastography; ultrasound; thermal ablation monitoring; intracardiac echocardiography; atrial fibrillation; CATHETER ABLATION; TISSUE ELASTICITY; FIBRILLATION; ECHOCARDIOGRAPHY; FEASIBILITY; EXPOSURE; MODULUS;
D O I
10.1118/1.4896820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radio frequency catheter ablation (RFCA) is a well-established clinical procedure for the treatment of atrial fibrillation (AF) but suffers from a low single-procedure success rate. Recurrence of AF is most likely attributable to discontinuous or nontransmural ablation lesions. Yet, despite this urgent clinical need, there is no clinically available imaging modality that can reliably map the lesion transmural extent in real time. In this study, the authors demonstrated the feasibility of shear-wave elastography (SWE) to map quantitatively the stiffness of RFCA-induced thermal lesions in cardiac tissues in vitro and in vivo using an intracardiac transducer array. Methods: SWE was first validated in ex vivo porcine ventricular samples (N = 5). Both B-mode imaging and SWE were performed on normal cardiac tissue before and after RFCA. Areas of the lesions were determined by tissue color change with gross pathology and compared against the SWE stiffness maps. SWE was then performed in vivo in three sheep (N = 3). First, the stiffness of normal atrial tissues was assessed quantitatively as well as its variation during the cardiac cycle. SWE was then performed in atrial tissue after RFCA. Results: A large increase in stiffness was observed in ablated ex vivo regions (average shear modulus across samples in normal tissue: 22 +/- 5 kPa, average shear-wave speed (ct): 4.5 +/- 0.4 m s(-1) and in determined ablated zones: 99 +/- 17 kPa, average ct: 9.0 +/- 0.5 m s(-1) for a mean shear modulus increase ratio of 4.5 +/- 0.9). In vivo, a threefold increase of the shear modulus was measured in the ablated regions, and the lesion extension was clearly visible on the stiffness maps. Conclusions: By its quantitative and real-time capabilities, Intracardiac SWE is a promising intraoperative imaging technique for the evaluation of thermal ablation during RFCA. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Comparison of techniques for estimating shear-wave velocity in arterial wall using shear-wave elastography - FEM and phantom study
    Jang, Jun-keun
    Kondo, Kengo
    Namita, Takeshi
    Yamakawa, Makoto
    Shiina, Tsuyoshi
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [22] Shear-Wave Elastography of Segmental Infarction of the Testis
    Kantarci, Fatih
    Olgun, Deniz Cebi
    Mihmanli, Ismail
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 820 - 822
  • [23] Shear-Wave Elastography in the Characterization of Pleural Effusions
    Ozgokce, Mesut
    Durmaz, Fatma
    Yavuz, Alpaslan
    Urley, Ibrahim
    Yildiz, Hanifi
    Arslan, Harun
    Dundar, Ilyas
    Havan, Nuri
    Ogul, Havri
    ULTRASOUND QUARTERLY, 2019, 35 (02) : 164 - 168
  • [24] Noninvasive Evaluation of Liver Fibrosis by Using Two-dimensional Shear-Wave Elastography Response
    Zheng, Jian
    Zheng, Rongqin
    RADIOLOGY, 2016, 280 (01) : 324 - 324
  • [25] Quantitative shear-wave optical coherence elastography with a programmable phased array ultrasound as the wave source
    Song, Shaozhen
    Le, Nhan Minh
    Huang, Zhihong
    Shen, Tueng
    Wang, Ruikang K.
    OPTICS LETTERS, 2015, 40 (21) : 5007 - 5010
  • [26] Limitations and artifacts in shear-wave elastography of the liver
    Bruce M.
    Kolokythas O.
    Ferraioli G.
    Filice C.
    O’Donnell M.
    Biomedical Engineering Letters, 2017, 7 (2) : 81 - 89
  • [27] REGULARIZED TRACKING OF SHEAR-WAVE IN ULTRASOUND ELASTOGRAPHY
    Horeh, Mahmoud Derakhshan
    Asif, Amir
    Rivaz, Hassan
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 6264 - 6268
  • [28] Monitoring Liver Stiffness Changes during Controlled Hyperthermia and Microwave Ablation Using Point Shear-Wave Elastography
    Wilkins, Luke
    RADIOLOGY-IMAGING CANCER, 2019, 1 (02):
  • [29] The Preciseness in Diagnosing Thyroid Malignant Nodules Using Shear-Wave Elastography
    Chang, Na
    Zhang, Xianchao
    Wan, Wenjing
    Zhang, Chengqi
    Zhang, Xianqi
    MEDICAL SCIENCE MONITOR, 2018, 24 : 671 - 677
  • [30] VISCOELASTICITY MEASUREMENT IN RAT LIVERS USING SHEAR-WAVE US ELASTOGRAPHY
    Sugimoto, Katsutoshi
    Moriyasu, Fuminori
    Oshiro, Hisashi
    Takeuchi, Hirohito
    Yoshimasu, Yu
    Kasai, Yoshitaka
    Furuichi, Yoshihiro
    Itoi, Takao
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (09): : 2018 - 2024