Activity determination of 59Fe

被引:4
|
作者
Kossert, Karsten [1 ]
Naehle, Ole J. [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
Fe-59; Activity standardization; TDCR CIEMAT/NIST efficiency tracing; Complex beta-gamma decay; ACTIVITY STANDARDIZATION; I-131;
D O I
10.1016/j.apradiso.2014.01.013
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Iron-59 was measured in three commercial and two custom-built liquid scintillation counters. The counting efficiencies were determined using CIEMAT/NIST efficiency tracing and the triple-todouble coincidence ratio (TDCR) method, respectively. The efficiency computation for the TDCR method was realized by means of the MICELLE2 program, applying a stochastic model for the computation of electron emission spectra. The program was extended to make calculations of spectra originating from complex decay schemes possible. In addition, a new parameterization of electron stopping powers for 10 commercial liquid scintillation cocktails was included in the software. The activities determined with the two methods were in very good agreement; the relative standard uncertainty of the combined result was found to be 0.16%. It was used to calibrate a 47r ionization chamber at PTB for future calibrations of this isotope which is used for investigations of iron metabolism. A standardized solution was submitted to the Bureau International des Poids et Mesures (BIPM) to be measured in the ionization chambers of the International Reference System (SIR) for comparison purposes. The liquid scintillation samples were also measured in a new portable TDCR system with three channel photomultipliers. Although this system has a much lower counting efficiency, the activity was in satisfactory agreement with the conventional TDCR system. The usage of the portable TDCR system, thus, provides an important test of the free parameter model. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:33 / 37
页数:5
相关论文
共 50 条
  • [21] PRECISION WHOLE BODY COUNTING OF 59FE IN HUMANS
    PALMER, HE
    COOK, J
    PAILTHOR.KG
    FINCH, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 163 - &
  • [22] Uptake of 59Fe from soluble 59Fe-humate complexes by cucumber and barley plants
    S. Cesco
    M. Nikolic
    V. Römheld
    Z. Varanini
    R. Pinton
    [J]. Plant and Soil, 2002, 241 : 121 - 128
  • [23] DETERMINATION OF 54Mn AND 59Fe SPECIFIC ACTIVITIES IN IRON PLATES ACTIVATION DETECTORS
    Dobrev, Lyuben
    Mitev, Mladen
    Dimitrov, Dobromir
    Nonova, Tzvetana
    Zahariev, Zahari
    Dimitrova, Desislava
    Krstevski, Srgjan
    Slavchev, Bozhidar
    [J]. COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2023, 76 (12): : 1820 - 1826
  • [24] Uptake of 59Fe from soluble 59Fe-humate complexes by cucumber and barley plants
    Cesco, S
    Nikolic, M
    Römheld, V
    Varanini, Z
    Pinton, R
    [J]. PLANT AND SOIL, 2002, 241 (01) : 121 - 128
  • [25] Standardization of 59Fe by efficiency extrapolation 4πβ-γ anticoincidence method
    da Silva, C. J.
    da Cruz, P. A. L.
    Iwahara, A.
    Loureiro, J. S.
    Ruzzarin, A.
    Tauhata, L.
    [J]. 2017 JOINT IMEKO TC1-TC7-TC13 SYMPOSIUM: MEASUREMENT SCIENCE CHALLENGES IN NATURAL AND SOCIAL SCIENCES, 2018, 1044
  • [26] Transport of foliar applied iron (59Fe) in Vicia faba
    Hüve, K
    Remus, R
    Lüttschwager, D
    Merbach, W
    [J]. JOURNAL OF PLANT NUTRITION, 2003, 26 (10-11) : 2231 - 2242
  • [27] Standardization of 59Fe by 4π(PC)β-γ software coincidence system
    Koskinas, M. F.
    Polillo, G.
    Brancaccio, F.
    Yamazaki, I. M.
    Dias, M. S.
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 109 : 386 - 388
  • [28] STUDY OF HEMATOPOIESIS IN RIBOFLAVIN DEFICIENT RATS WITH 59FE AS TRACER
    JAMDAR, SC
    UDUPA, KB
    CHATTERJI, A
    [J]. JOURNAL OF VITAMINOLOGY, 1968, 14 (03): : 219 - &
  • [29] POSSIBILITIES AND LIMITS OF IRONKINETICS WITH 59FE - (REMARKS ON ITS EXECUTION AND INTERPRETATION)
    SCANDELLARI, C