Development of apparatus for phase Imaging using X-ray interferometers at BL20XU of SPring-8

被引:0
|
作者
Momose, A [1 ]
Koyama, I [1 ]
Hamaishi, Y [1 ]
Kawamoto, S [1 ]
Takai, K [1 ]
Uesugi, K [1 ]
Suzuki, Y [1 ]
机构
[1] Univ Tokyo, Grad Sch Frontier Sci, Dept Adv Mat Sci, Bunkyo Ku, Tokyo 1130033, Japan
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Phase-contrast X-ray imaging, including phase tomography, was performed at the medium-length beamline BL20XU of SPring-8, where undulator X rays were available at 245 m from the source point. A crystal X-ray interferometer and an X-ray Talbot interferometer with transmission gratings were used to perform different kinds of phase-contrast imaging. The crystal X-ray interferometer was devised in that a crystal lamella for beam recombination was thinned down to 40 mum to achieve high-resolution imaging. A quick fringe-scanning mechanism was also constructed enabling the phase measurement with a few second and therefore phase tomography with several minutes. The X-ray Talbot interferometer was studied as a novel and simple method that generated a contrast corresponding to differential phase. Phase tomography was also attained with the X-ray Talbot interferometer.
引用
收藏
页码:1259 / 1262
页数:4
相关论文
共 50 条
  • [21] X-ray pinpoint structural measurement for nanomaterials and devices at BL40XU of the SPring-8
    Kimura, Shigeru
    Moritomo, Yutaka
    Tanaka, Yoshihito
    Tanaka, Hitoshi
    Toriumi, Koshiro
    Kato, Kenichi
    Yasuda, Nobuhiro
    Fukuyama, Yoshimitsu
    Kim, Jungeun
    Murayama, Haruno
    Takata, Masaki
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1238 - +
  • [22] Scanning hard X-ray microscope with tantalum phase zone plate at the Hyogo-BL (BL24XU) of SPring-8
    Kagoshima, Y
    Takai, K
    Ibuki, T
    Yokoyama, Y
    Hashida, T
    Yokoyama, K
    Takeda, S
    Urakawa, M
    Miyamoto, N
    Tsusaka, Y
    Matsui, J
    Aino, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 872 - 876
  • [23] A wavelength dispersive X-ray spectrometer for small area X-ray fluorescence spectroscopy at SPring-8 BL39XU
    Hayakawa, S
    Yamaguchi, A
    Hong, W
    Gohshi, Y
    Yamamoto, T
    Hayashi, K
    Kawai, J
    Goto, S
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (01) : 171 - 177
  • [24] Atmospheric coherent X-ray diffraction imaging for in situ structural analysis at SPring-8 Hyogo beamline BL24XU
    Takayama, Yuki
    Takami, Yuki
    Fukuda, Keizo
    Miyagawa, Takamasa
    Kagoshima, Yasushi
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1229 - 1237
  • [25] Development of high lateral and wide angle resolved hard X-ray photoemission spectroscopy at BL47XU in SPring-8
    Ikenaga, Eiji
    Kobata, Masaaki
    Matsuda, Hiroyuki
    Sugiyama, Takeharu
    Daimon, Hiroshi
    Kobayashi, Keisuke
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2013, 190 : 180 - 187
  • [26] Upgrade status of hard X-ray 100-nm probe beamlines BL37XU and BL39XU at SPring-8
    Koyama, Takahisa
    Yumoto, Hirokatsu
    Terada, Yasuko
    Suzuki, Motohiro
    Kawamura, Naomi
    Mizumaki, Masaichiro
    Nariyama, Nobuteru
    Matsushita, Tomohiro
    Ishizawa, Yasuhide
    Furukawa, Yukito
    Ohata, Toru
    Yamazaki, Hiroshi
    Takeuchi, Tomoyuki
    Senba, Yasunori
    Matsuzaki, Yasuhisa
    Tanaka, Masayuki
    Shimizu, Yasuhiro
    Kishimoto, Hikaru
    Miura, Takanori
    Kimura, Hiroaki
    Takeshita, Kunikazu
    Ohashi, Haruhiko
    Yamamoto, Masaki
    Goto, Shunji
    Takata, Masaki
    Ishikawa, Tetsuya
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VI, 2011, 8139
  • [27] Optical design and performance of the Taiwan inelastic X-ray Scattering beamline (BL12XU) at SPring-8
    Cai, YQ
    Chow, P
    Chen, CC
    Ishii, H
    Tsang, KL
    Kao, CC
    Liang, KS
    Chen, CT
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 340 - 343
  • [28] Total x-ray scattering setup for crystalline particles at SPring-8 BL15XU NIMS beamline
    Seo, Okkyun
    Kumara, L. S. R.
    Kim, Jaemyung
    Hiroi, Satoshi
    Kusada, Kohei
    Kitagawa, Hiroshi
    Sakata, Osami
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (11):
  • [29] Subnanosecond-resolved X-ray diffraction at the SPring-8 high flux beamline BL40XU
    Adachi, S
    Inoue, K
    Oka, T
    Yagi, N
    Tanaka, Y
    Ishikawa, T
    Shiro, Y
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1383 - 1386
  • [30] Real-time phase-contrast x-ray imaging using two-dimensionally expanded synchrotron radiation x-rays at the BL24XU (Hyogo-BL) of the SPring-8
    Kagoshima, Y
    Tsusaka, Y
    Matsui, J
    Yokoyama, K
    Takai, K
    Takeda, S
    Kobayashi, K
    Kimura, H
    Kimura, S
    Izumi, K
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 41 - 44