Research on the Modal Damping Ratio for Stay Cable With Viscoselasticity Damper in Cable-Stayed Bridges

被引:0
|
作者
Chen, ShuiSheng [1 ]
Wang, DeShan [2 ]
机构
[1] East China Jiaotong Univ, Dept Civil Engn, Nanchang 330013, Peoples R China
[2] Jiangxi Ganyue Expressway Co LTD, Nanchang 330025, Jiangxi, Peoples R China
关键词
Modal damping ratio; Viscoselasticity damper; Difference method; Stay cables;
D O I
10.4028/www.scientific.net/AMR.779-780.671
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Taking the bending stiffness, cable static sag and cable inclined angle into consideration, equations of space free vibration of the cable-damper system are derived in this paper. Joining the variable separation strategy and center difference method, the partial differential equations are discretized in space and a set of complex eigenvalue equations, which are solved by state space method, are derived, and both the maximum modal damping ration and the optimal damper parameter are obtained. Several typical stay cables are investigated for both the in-plane and out-of-plane modes under different cable parameters and damper parameters. The results demonstrate that modal damping ratio for the first in-plane mode is significantly affected by the cable static sag only, but those for the other modes affected by cable sag are slight, and cable static sag do not affect the optimal damper parameter for all modes, however the bending stiffness will changes both the maximum modal damping ratios and the optimal damper parameters. Some valuable suggestions are proposed for the optimal damper design.
引用
收藏
页码:671 / +
页数:2
相关论文
共 50 条
  • [41] The use of modal-combination rules with cable-stayed bridges
    Walker, C.
    Stafford, P. J.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-BRIDGE ENGINEERING, 2010, 163 (04) : 225 - 240
  • [42] Mode-dependence of structural damping in cable-stayed bridges
    Yamaguchi, H
    Ito, M
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 72 (1-3) : 289 - 300
  • [43] Exploring damping characteristics of composite tower of cable-stayed bridges
    SHEHATA E ABDEL RAHEEM
    [J]. Sādhanā, 2016, 41 : 345 - 358
  • [44] Elastoplastic cable pair and viscous damper used in the lateral seismic isolation of cable-stayed bridges
    You H.
    Guan Z.
    [J]. Guan, Zhongguo, 1600, Chinese Vibration Engineering Society (36): : 183 - 188
  • [45] The impact of cable spacing on the behavior of cable-stayed bridges
    Al-Rousan, R.
    [J]. MAGAZINE OF CIVIL ENGINEERING, 2019, 91 (07): : 49 - 59
  • [46] EFFECT OF CABLE STIFFNESS ON CABLE-STAYED BRIDGES - DISCUSSION
    HEGAB, HIA
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1987, 113 (11): : 2309 - 2309
  • [47] Measuring Methods of Cable Tension in Cable-Stayed Bridges
    Sun, Jiangbo
    Zhao, Zuozhou
    Zhao, Honghua
    [J]. MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-3, 2011, 295-297 : 1230 - +
  • [48] Determination of the initial cable forces for cable-stayed bridges
    Shijiazhuang Railway Inst, Shijiazhuang, China
    [J]. Gong Cheng Li Xue/Engineering Mechanics, 2000, 17 (03): : 121 - 126
  • [49] IMPORTANCE OF CABLE VIBRATION IN DYNAMICS OF CABLE-STAYED BRIDGES
    ABDELGHAFFAR, AM
    KHALIFA, MA
    [J]. JOURNAL OF ENGINEERING MECHANICS-ASCE, 1991, 117 (11): : 2571 - 2589
  • [50] Modeling of cable vibration effects of cable-stayed bridges
    Cheng S.H.
    Lau D.T.
    [J]. Earthquake Engineering and Engineering Vibration, 2002, 1 (01) : 74 - 85