Health Monitoring System Based on Intra-Body Communication

被引:0
|
作者
Razak, A. H. A. [1 ]
Ibrahim, I. W. [1 ]
Ayub, A. H. [1 ]
Amri, M. F. [1 ]
Hamzi, M. H. [1 ]
Halim, A. K. [1 ]
Ahmad, A. [1 ]
Al Junid, S. A. M. [1 ]
机构
[1] Univ Teknol MARA, Fac Elect Engn FKE, Ctr Elect Engn Studies CEES, Shah Alam 40450, Malaysia
关键词
D O I
10.1088/1757-899X/99/1/012028
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a model of a Body Area Network (BAN) health monitoring system based on Intra-Body Communication. Intra-body Communication (IBC) is a communication technique that uses the human body as a medium for electrical signal communication. One of the visions in the health care industry is to provide autonomous and continuous self and the remote health monitoring system. This can be achieved via BAN, LAN and WAN integration. The BAN technology itself consists of short range data communication modules, sensors, controller and actuators. The information can be transmitted to the LAN and WAN via the RF technology such as Bluetooth, ZigBee and ANT. Although the implementations of RF communication have been successful, there are still limitations in term of power consumption, battery lifetime, interferences and signal attenuations. One of the solutions for Medical Body Area Network (MBANs) to overcome these issues is by using an IBC technique because it can operate at lower frequencies and power consumption compared to the existing techniques. The first objective is to design the IBC's transmitter and receiver modules using the off the shelf components. The specifications of the modules such as frequency, data rate, modulation and demodulation coding system were defined. The individual module were designed and tested separately. The modules was integrated as an IBC system and tested for functionality then was implemented on PCB. Next objective is to model and implement the digital parts of the transmitter and receiver modules on the Altera's FPGA board. The digital blocks were interfaced with the FPGA's on board modules and the discrete components. The signals that have been received from the transmitter were converted into a proper waveform and it can be viewed via external devices such as oscilloscope and Labview. The signals such as heartbeats or pulses can also be displayed on LCD. In conclusion, the IBC project presents medical health monitoring model that operates at the range of 21 MHz frequency and reduce the power consumption for a longer battery lifetime.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Finite-element modeling and simulations of the intra-body communication used for biomedical monitoring
    [J]. Song, Y. (yongsong@bit.edu.cn), 1600, Beijing Institute of Technology (23):
  • [22] Signal Measurement System for Intra-Body Communication Using Optical Isolation Method
    Matsumoto, Kazuki
    Katsuyama, Jun
    Sugiyama, Ryo
    Takizawa, Yasuaki
    Ishii, Seita
    Shinagawa, Mitsuru
    Kado, Yuichi
    [J]. OPTICAL REVIEW, 2014, 21 (05) : 614 - 620
  • [23] Dynamic Interference Estimation in Secure Gate System using Intra-body Communication
    Wada, Yuki
    Furuya, Keisuke
    Kato, Ryota
    Shinagawa, Mitsuru
    [J]. PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 2547 - 2550
  • [24] Basic study of a transcutaneous information transmission system using intra-body communication
    Okamoto, Eiji
    Sato, Yusuke
    Seino, Kazuyuki
    Kiyono, Takashi
    Kato, Yoshikuni
    Mitamura, Yoshinori
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2010, 13 (02) : 117 - 120
  • [25] Signal measurement system for intra-body communication using optical isolation method
    Kazuki Matsumoto
    Jun Katsuyama
    Ryo Sugiyama
    Yasuaki Takizawa
    Seita Ishii
    Mitsuru Shinagawa
    Yuichi Kado
    [J]. Optical Review, 2014, 21 : 614 - 620
  • [26] Basic study of a transcutaneous information transmission system using intra-body communication
    Eiji Okamoto
    Yusuke Sato
    Kazuyuki Seino
    Takashi Kiyono
    Yoshikuni Kato
    Yoshinori Mitamura
    [J]. Journal of Artificial Organs, 2010, 13 : 117 - 120
  • [27] Development and Prospect of Implantable Intra-Body Communication Technology
    Zhang, Shuang
    Qin, Yuping
    Kuang, Jiangming
    Mak, Peng Un
    Pun, Sio Hang
    Vai, Mang I.
    Liu, Yihe
    [J]. JOURNAL OF COMPUTERS, 2014, 9 (02) : 463 - 474
  • [28] Review of the Modeling, Simulation and Implement of Intra-body Communication
    SONG Yong
    HAO Qun
    ZHANG Kai
    [J]. Defence Technology, 2013, (01) : 11 - 20
  • [29] Establishment of Theoretical Head Model in Intra-body Communication
    Zhang, Shuang
    Qin, Yu-ping
    Zhu, Jin
    [J]. 2012 7TH INTERNATIONAL CONFERENCE ON SYSTEM OF SYSTEMS ENGINEERING (SOSE), 2012, : 298 - 300
  • [30] Review of the Modeling, Simulation and Implement of Intra-body Communication
    SONG Yong
    HAO Qun
    ZHANG Kai
    [J]. Defence Technology., 2013, 9 (01) - 20