Performance analysis of vacuum membrane distillation regenerator in liquid desiccant air conditioning system

被引:20
|
作者
Zhou, Junming [1 ]
Zhang, Xiaosong [1 ,2 ]
Su, Wei [1 ]
Sun, Bo [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Minist Educ, Key Lab Energy Thermal Convers & Control, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid regeneration; Modeling; Heat and mass transfer; VMD; DESALINATION; SIMULATION; ENERGY;
D O I
10.1016/j.ijrefrig.2019.03.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to solve the problem of poor regeneration performance of the solar solution dehumidification air conditioning regeneration system under high temperature and high humidity weather conditions. In this paper, a novel vacuum membrane distillation (VMD) solution regeneration method was proposed for a solution desiccant air conditioning system, and a theoretical study of this novel regenerator is performed. Through the analysis of heat and mass transfer, the mathematical model of VMD regeneration is established, and the mathematical model is verified by experiments. The results indicated that VMD regenerator not only could increase the regenerate rate but also could exhibit higher energy utilization efficiency. At the same concentration, the VMD regenerator has a higher regeneration performance, and the regeneration rate is 1.6-2.4 times that of the internal heat type regenerator, and the 4.5-6 times that of the adiabatic regenerator. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
下载
收藏
页码:112 / 121
页数:10
相关论文
共 50 条
  • [21] Performance analysis of a novel multi-function liquid desiccant regeneration system for liquid desiccant air-conditioning system
    Cheng, Qing
    Xu, Wenhao
    ENERGY, 2017, 140 : 240 - 252
  • [22] Performance analysis of a hybrid desiccant air conditioning system
    Jia, Chun-Xia
    Dai, Yan-Jun
    Wu, Jing-Yi
    Zhong, Jin-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2005, 26 (06): : 921 - 923
  • [23] Liquid desiccant based solar air conditioning system with novel evacuated tube collector as regenerator
    Mehta, J. R.
    Rane, M. V.
    CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 688 - 693
  • [24] PERFORMANCE ANALYSIS ON THE DIFFERENT AIR MIXING MODES OF LIQUID DESICCANT BASED AIR CONDITIONING SYSTEM
    Niu, X. F.
    Xiao, F.
    Wang, S. W.
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE URBANIZATION (ICSU 2010), 2010, : 1839 - 1847
  • [25] Performance evaluation of the electrodialysis regenerator for the lithium bromide solution with high concentration in the liquid desiccant air-conditioning system
    Pei, Wang
    Cheng, Qing
    Jiao, Shun
    Liu, Lin
    ENERGY, 2019, 187
  • [26] Performance Evaluation of a Three-Fluid Liquid Desiccant Membrane Air-Conditioning System
    Storle, Devin
    Abdel-Salam, Mohamed R. H.
    Simonson, Carey J.
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 2, 2019, 125 : 558 - 575
  • [27] Analysis and modeling of solar liquid desiccant air conditioning system
    Fang, Chengchao
    Sun, Ketao
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1997, 18 (02): : 128 - 133
  • [28] Hybrid solar still - Liquid desiccant regenerator and water distillation system
    Shukla, Dhruvin L.
    Modi, Kalpesh, V
    SOLAR ENERGY, 2019, 182 : 117 - 133
  • [29] Performance Analysis of Hybrid Air-Conditioning System with Integrated Liquid Desiccant Dehumidification
    Zhang, Li
    Hihara, Eiji
    Dang, Chaobin
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 535 - 540