Large area mercuric iodide x-ray imager

被引:10
|
作者
Zentai, G [1 ]
Partain, L [1 ]
Pavlyuchkova, R [1 ]
Virshup, G [1 ]
Zuck, A [1 ]
Melekhov, L [1 ]
Dagan, O [1 ]
Vilensky, A [1 ]
Gilboa, H [1 ]
机构
[1] Varian Med Syst, Ginzton Technol Ctr, Mt View, CA 94043 USA
关键词
imaging; X-ray radiology; polycrystalline; mercuric iodide; imaging detectors; Flat-Panel imaging arrays;
D O I
10.1117/12.465604
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Single crystals of mercuric iodide have been studied for many years for nuclear detectors. We have investigated the use of x-ray photoconductive polycrystalline mercuric iodide coatings on amorphous silicon flat panel thin film transistor (TFT) arrays as x-ray detectors for radiographic and fluoroscopic applications in medical imaging. The mercuric iodide coatings were vacuum deposited by Physical Vapor Deposition (PVD). This coating technology is capable of being scaled up to sizes required in common medical imaging applications. Coatings were deposited on 4" X 4" TFT arrays for imaging performance evaluation and also on conductive-coated glass substrates for measurements of x-ray sensitivity, dark current and image lag. The TFT arrays used included pixel pitch dimensions of both 100 and 139 microns. Coating thickness between 150 microns and 250 microns were tested in the 25 kVp-100 kVp x-ray energy range utilizing exposures typical for both fluoroscopic, and radiographic imaging. X-ray sensitivities measured for the mercuric iodide samples and coated TFT detectors were superior to any published results for competitive materials (up to 7100 ke/mR/pixel for 100 micron pixels). It is believed that this higher sensitivity, can result in fluoroscopic imaging signal levels high enough to overshadow electronic noise. Image lag characteristics appear adequate for fluoroscopic rates. Resolution tests on resolution target phantoms showed that resolution is limited to the Nyquist frequency for the 139 micron (resolution similar to3.6 lp/mm) pixel detectors. The ability to operate at low voltages (similar to100 V) gives adequate dark currents for most applications and allows low voltage electronics designs. Mercuric Iodide coated TFT arrays were found to be outstanding candidates for direct digital radiographic detectors for both static and dynamic (fluoroscopic) applications. Their high x-ray sensitivity, high resolution, low dark current, low voltage operation, and good lag characteristics provide a unique combination of desirable imaging performance parameters.
引用
收藏
页码:592 / 600
页数:3
相关论文
共 50 条
  • [1] Study on growth of large area mercuric iodide polycrystalline film and its X-ray Imaging
    Xu, Gang
    Guo, Yanfei
    Xi, Zengzhe
    Gu, Zhi
    Zhang, Lan
    Yu, Wentao
    Ma, Xuming
    Li, Bo
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGING SPECTROSCOPY; AND TELESCOPES AND LARGE OPTICS, 2014, 9298
  • [2] Large area mercuric iodide and lead iodide X-ray detectors for medical and non-destructive industrial imaging
    Zentai, G.
    Schieber, M.
    Partain, L.
    Pavlyuchkova, R.
    Proano, C.
    JOURNAL OF CRYSTAL GROWTH, 2005, 275 (1-2) : E1327 - E1331
  • [3] Large area mercuric iodide thick film X-ray detectors for fluoroscopic (on-line) imaging
    Zentai, G
    Partain, L
    Pavlyuchkova, R
    Proano, C
    Virshup, G
    Breen, BN
    Zuck, A
    Reisman, B
    Taieb, A
    Schieber, M
    SMART NONDESTRUCTIVE EVALUATION FOR HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS, 2002, 4702 : 446 - 453
  • [4] Comparison of mercuric iodide and lead iodide X-ray detectors for X-ray imaging applications
    Zentai, G
    Partain, L
    Pavlyuchkova, R
    Proano, C
    Schieber, M
    Shah, K
    Bennett, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2278 - 2282
  • [5] Comparison of mercuric iodide and lead iodide x-ray detectors for x-ray imaging applications
    Zentai, G.
    Partain, L.
    Pavlyuchkova, R.
    Proano, C.
    Schieber, A.
    Shah, K.
    Bennett, P.
    Melekhov, L.
    Gilboa, H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2506 - 2512
  • [6] Mercuric iodide X-ray and gamma ray detectors for astronomy
    van den Berg, L
    Sandoval, JS
    Vigil, R
    Richards, JD
    Vaccaro, FP
    Hykin, M
    DeVito, RP
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII, 2002, 4497 : 100 - 105
  • [7] X-RAY LUMINESCENCE OF MERCURIC IODIDE NUCLEAR DETECTORS
    PINSKY, E
    HALPERIN, A
    BEINGLASS, I
    SCHIEBER, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 260 - 263
  • [8] Reviewing polycrystalline mercuric iodide X-ray detectors
    Schieber, M.
    Zuck, A.
    Gilboa, H.
    Zentai, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2385 - 2391
  • [9] X-ray reflections from mercuric iodide.
    Havighurst, RJ
    AMERICAN JOURNAL OF SCIENCE, 1925, 10 (60) : 556 - 558
  • [10] Reviewing polycrystalline mercuric iodide X-ray detectors
    Schieber, M
    Zuck, A
    Gilboa, H
    Zentai, G
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4327 - 4331