Toxicological safety evaluation of gadobenate dimeglumine 0.5 M solution for injection (MultiHance®), a new magnetic resonance imaging contrast medium

被引:29
|
作者
Morisetti, A [1 ]
Bussi, S [1 ]
Tirone, P [1 ]
de Haën, C [1 ]
机构
[1] Bracco SpA, Dept Pharmacol, Milan Res Ctr, I-20134 Milan, Italy
关键词
gadobenate; toxicity; reproduction; mutagenicity;
D O I
10.1097/00004728-199911001-00025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To support the clinical use of gadobenate dimeglumine for injection as an intravascular magnetic resonance imaging contrast medium through an extensive battery of toxicological safety studies. Methods: Single and multiple dose toxicity, reproduction and mutagenicity assessments were carried out in rodents and non-rodents. Results: Initial adverse clinical signs in monkeys were associated with a systemic exposure 34 times higher than that found in humans after 0.1 mmol/kg gadobenate dimeglumine. Good systemic tolerance was observed in repeated dose toxicity studies. Reproductive performance and physical and behavioral development of offspring were unaffected at doses corresponding to 20 times the human dose. Mutagenicity tests excluded any genotoxic potential of gadobenate dimeglumine. Conclusion: Based on the wide margins of safety demonstrated in different species, particularly in primates, gadobenate dimeglumine can be considered as safe in the range of clinical doses recommended for magnetic resonance imaging.
引用
收藏
页码:S207 / S217
页数:11
相关论文
共 50 条
  • [31] Intraindividual comparison of 1.0 m gadobutrol and 0.5 m gadopentetate dimeglumine for time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the upper torso
    Fink, C
    Puderbach, M
    Ley, S
    Risse, F
    Kuder, TA
    Bock, M
    Thaler, J
    Plathow, C
    Kauczor, HU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 286 - 290
  • [32] Mangafodipir trisodium injection, a new contrast medium for magnetic resonance imaging: In vitro metabolism and protein binding studies of the active component MnDPDP in human blood
    Toft, KG
    Kindberg, GM
    Skotland, T
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (07) : 983 - 988
  • [33] Safety evaluation of a new setup for transcranial electric stimulation during magnetic resonance imaging
    Gregersen, Frodi
    Goksu, Cihan
    Schaefers, Gregor
    Xue, Rong
    Thielscher, Axel
    Hanson, Lars G.
    BRAIN STIMULATION, 2021, 14 (03) : 488 - 497
  • [34] Preclinical safety assessment of Vasovist (gadofosveset trisodium), a new magnetic resonance imaging contrast agent for angiography
    Steger-Hartmann, T
    Graham, PB
    Müller, S
    Schweinfurth, H
    INVESTIGATIVE RADIOLOGY, 2006, 41 (05) : 449 - 459
  • [35] Injection rate of contrast medium affects diagnostic ability of dynamic contrast-enhanced magnetic resonance imaging for endometrial carcinoma: a prospective cohort study
    Xu, Donghui
    Jin, Aiping
    Ge, Yongqian
    Zhang, Yanmei
    GLAND SURGERY, 2021, 10 (08) : 2462 - 2470
  • [36] MAGNETIC-RESONANCE-IMAGING OF THE NEUROONCOLOGY PATIENT - RESULTS USING A NEW LOW OSMOLAL CONTRAST-MEDIUM
    ROSA, L
    SCHELLINGER, D
    FRANCISCO, J
    CARVLIN, M
    ANNALS OF NEUROLOGY, 1991, 30 (02) : 272 - 272
  • [37] NONIONIC MAGNETIC-RESONANCE-IMAGING CONTRAST AGENTS - CLINICAL-TRIAL EXPERIENCE OF SAFETY, TOLERANCE, AND EFFICACY OF GADODIAMIDE INJECTION
    VANWAGONER, M
    OTOOLE, M
    QUAY, SC
    INVESTIGATIVE RADIOLOGY, 1990, 25 : S39 - S41
  • [38] Pre-clinical evaluation of gadobutrol: A new, neutral, extracellular contrast agent for magnetic resonance imaging
    Vogler, H
    Platzek, J
    SchuhmannGiampieri, G
    Frenzel, T
    Weinmann, HJ
    Raduchel, B
    Press, WR
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 1 - 10
  • [39] Evaluation of the clinical safety of gadodiamide injection, a new nonionic MRI contrast medium for the central nervous system: A European perspective
    Aslanian, V
    Lemaignen, H
    Bunouf, P
    Svaland, MG
    Borseth, A
    Lundby, B
    NEURORADIOLOGY, 1996, 38 (06) : 537 - 541
  • [40] EVALUATION OF THE SAFETY AND EFFICACY OF GADOTERIDOL INJECTION (A LOW OSMOLAL MAGNETIC-RESONANCE CONTRAST AGENT) - CLINICAL-TRIALS REPORT
    DESIMONE, D
    MORRIS, M
    RHODA, C
    LUCAS, T
    ZIELONKA, J
    OLUKOTUN, A
    CARVLIN, M
    INVESTIGATIVE RADIOLOGY, 1991, 26 : S212 - S216