Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method

被引:40
|
作者
Khodadoust, Saeid [1 ]
Ghaedi, Mehrorang [1 ]
机构
[1] Univ Yasuj, Dept Chem, Yasuj 7591435, Iran
关键词
Methyl red; Dispersive liquid liquid microextraction; Box-Behnken design; Desirability function; LIQUID-LIQUID MICROEXTRACTION; PHOTOCATALYTIC DEGRADATION; PHASE MICROEXTRACTION; ORANGE-G; DYE; PRECONCENTRATION; DESIGN; OPTIMIZATION; PESTICIDES; SEPARATION;
D O I
10.1016/j.saa.2014.04.119
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME)) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100 mu L of chloroform, 1.3 mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0 mg mL(-1) of MR in initial solution with R-2 = 0.995 (n = 5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015 mg mL(-1), respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n = 5). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [21] Vortex-assisted natural deep eutectic solvent microextraction using response surface methodology optimization for determination of orthophosphate in water samples by molybdenum blue method
    Najafi, Amir
    Hashemi, Mahdi
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (19) : 3102 - 3109
  • [22] Determination of trace copper (II) in water samples by kinetic-spectrophotometry
    Qi Y.
    Ji H.
    Xin H.
    Liu L.
    Journal of Ocean University of China, 2007, 6 (2) : 143 - 146
  • [23] DETERMINATION OF VANADIUM IN WATER AND AIR SAMPLES BY ATOMIC-ABSORPTION SPECTROPHOTOMETRY
    ADACHI, A
    OGAWA, K
    TSUSHI, Y
    NAGAO, N
    KOBAYASHI, T
    JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1995, 41 (01): : P19 - P19
  • [24] Experimental Design and Response Surface Modeling: A Method Development Application for the Determination of Reduced Inorganic Species in Environmental Samples
    Hanrahan, G.
    Garza, C.
    Garcia, E.
    Miller, K.
    JOURNAL OF ENVIRONMENTAL INFORMATICS, 2007, 9 (02) : 71 - 79
  • [25] Determination of phenol in tap water and river water samples by solid-phase spectrophotometry
    Nukatsuka, I
    Nakamura, S
    Watanabe, K
    Ohzeki, K
    ANALYTICAL SCIENCES, 2000, 16 (03) : 269 - 273
  • [26] Determination of Phenol in Tap Water and River Water Samples by Solid-Phase Spectrophotometry
    Isoshi Nukatsuka
    Sachiko Nakamura
    Kaori Watanabe
    Kunio Ohzeki
    Analytical Sciences, 2000, 16 : 269 - 273
  • [27] Determination of polycyclic aromatic hydrocarbons in smoked fish samples by a new microextraction technique and method optimisation using response surface methodology
    Mohammadi, Abdorreza
    Ghasemzadeh-Mohammadi, Vahid
    Haratian, Parivash
    Khaksar, Ramin
    Chaichi, Maryam
    FOOD CHEMISTRY, 2013, 141 (03) : 2459 - 2465
  • [28] METHOD FOR MOLECULAR VISIBLE ABSORPTION SPECTROPHOTOMETRY FOR DETERMINATION OF IODIDE IN URINE SAMPLES
    Matheus, Pedro
    Flores, Mary
    Bello, Ana
    Belandria, Olga
    ACTA BIOCLINICA, 2015, 5 (10): : 85 - 102
  • [29] Simultaneous determination of cationic dyes in water samples with dispersive liquid-liquid microextraction followed by spectrophotometry: experimental design methodology
    Asfaram, Arash
    Ghaedi, Mehrorang
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (05) : 4793 - 4802