The implantable cardioverter defibrillator in congestive heart failure patients in primary prevention: assessment of neuropsychological impact

被引:0
|
作者
Garnero, S. [1 ]
Pomero, A. [1 ]
Vallauri, P. [2 ]
Leto, L. [3 ]
Testa, M. [3 ]
Feola, M. [1 ]
机构
[1] Osped SS Trinita, Cardiovasc Rehabil Heart Failure Unit, I-12045 Fossano, Cuneo, Italy
[2] Psychol Serv ASL CN1, Cuneo, Italy
[3] Univ Turin, Sch Geriatry, Turin, Italy
来源
MINERVA CARDIOANGIOLOGICA | 2014年 / 62卷 / 04期
关键词
Mild cognitive impairment; Anxiety; Depression; Heart failure; Defibrillators; implantable; COGNITIVE IMPAIRMENT; DEPRESSION; PREVALENCE; GUIDELINES; ANXIETY; ESC;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim. Cognitive impairment, anxiety and depression have been described in patients with congestive heart failure (CHF). The aim was to analyse the prevalence of cognitive impairment and anxiety-depression in an in-hospital CHF population before discharge attempting to correlate with the presence of an implantable cardioverter defibrillator (ICD). Methods. All subjects underwent a mini mental state examination (MMSE), geriatric depression scale (GDS), hospital anxiety and depression scale test (HADS). Results. Three-hundred and eighteen CHF patients (age 71.6 years, 195 males) were analysed. The mean New York Heart Association class (NYHA) was 2.9 +/- 0.8, left ventricular ejection fraction (LVEF) was 43.4 +/- 15.8%; brain natriuretic peptide (BNP) plasma level was 579.8 +/- 688.4 pg/mL. In 9.6% a pathological MMSE score emerged; a depression of mood in 18.2% and anxiety in 23.4% of patients were observed. An ICD was implanted in 43 (14.2%) CHF patients for primary prevention of cardiac sudden death. Patients in ICD group demonstrated a higher prevalence of renal impairment (creatinine 1.7 +/- 0.7 vs. 1.2 +/- 0.8 mg/dL; P=0.0001), lower LVEF (24.9 +/- 8.9 vs. 46.2 +/- 14.6% P=0.0001) and higher BNP (717.1 +/- 538 vs. 345.4 +/- 448.6 pg/ml; P=0.0001) but similar 6-minute walking test (338.6 +/- 81.3 vs. 345.3 +/- 114.9 m; P=0.8). An ICD intervention was registered in 9 (20.9%) patients. Although clinical parameters seemed to describe a sicker population in ICD implanted patients, from neuropsychological tests did not emerge any significant differences (PINS for MMSE, GDS and HADS). Conclusion. ICD-implanted CHF patients for primary prevention did not reveal a worsening in anxiety and depression of mood demonstrating a similar cognitive performance in comparison with non-ICD implanted.
引用
收藏
页码:321 / 326
页数:6
相关论文
共 50 条
  • [31] Frequency, predictors and prognostic impact of implantable cardioverter defibrillator shocks in a primary prevention population with heart failure and reduced ejection fraction
    Masini, Marta
    Elia, Edoardo
    Vianello, Pier Filippo
    Bertero, Giovanni
    Rossi, Paolo
    Ameri, Pietro
    Chiarella, Francesco
    Brunelli, Claudio
    Porto, Italo
    Sartori, Paolo
    Canepa, Marco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2021, 22 (02) : 118 - 125
  • [32] Mortality among ischemic and nonischemic heart failure patients with a primary implantable cardioverter-defibrillator
    Yang, Pil-Sung
    Kang, Younghyun
    Bae, Han-Joon
    Sung, Jung-Hoon
    Park, Hyung-Deuk
    Joung, Boyoung
    JOURNAL OF ARRHYTHMIA, 2021, 37 (06) : 1537 - 1545
  • [33] The Timing of Implantable Cardioverter-Defibrillator Implantation in Patients with Heart Failure
    Nawaf S. Al-Majed
    Justin A. Ezekowitz
    Current Cardiology Reports, 2012, 14 : 299 - 307
  • [34] Implantable cardioverter defibrillator in advanced heart failure patients: prognostic implications
    Ruocco, Gaetano
    Rossi, Arianna
    Pastorini, Guido
    Testa, Marzia
    Feola, Mauro
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0N) : N99 - N99
  • [35] The Timing of Implantable Cardioverter-Defibrillator Implantation in Patients with Heart Failure
    Al-Majed, Nawaf S.
    Ezekowitz, Justin A.
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (03) : 299 - 307
  • [36] Heart failure: the challenge of selecting patients for implantable cardioverter defibrillator therapy
    Chandrasekaran, Badri
    Cowburn, Peter J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (04) : 461 - 467
  • [37] Daily shock impedance measured by Implantable Cardioverter defibrillator is useful in the management of congestive heart failure
    Matsushita, Kohei
    Ishikawa, Toshiyuki
    Sumita, Shinichi
    Kobayashi, Tsukasa
    Ogawa, Hideyuki
    Inoue, Noriko
    Matsumoto, Katsumi
    Taima, Minoru
    Nakazawa, Ichirou
    Sugano, Teruyasu
    Ishigarni, Tomoaki
    Uchino, Kazuaki
    Umemura, Satoshi
    CIRCULATION JOURNAL, 2006, 70 (11) : 1462 - 1465
  • [38] Recent primary prevention implantable cardioverter defibrillator trials
    Duray, G
    Israel, CW
    Hohnloser, SH
    CURRENT OPINION IN CARDIOLOGY, 2006, 21 (01) : 15 - 19
  • [39] Syncope in Primary Prevention Implantable Cardioverter Defibrillator Implantation
    Goldenberg, Gustavo
    Bental, Tamir
    Kadmon, Udi
    Zabarsky, Ronit
    Kusnick, Jairo
    Barsheshet, Alon
    Golovchiner, Gregory
    Strasberg, Boris
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2017, 19 (01): : 15 - 18
  • [40] Impact of nutritional status on heart failure hospitalization and mortality in nonischemic patients with implantable cardioverter defibrillator
    Oyabu, K. Kenjiro
    Suzuki, A.
    Shiga, T.
    Jujo, K.
    Higuchi, S.
    Iwanami, Y.
    Yagishita, D.
    Ejima, K.
    Shoda, M.
    Hagiwara, N.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 96 - 96