Pulmonary embolism: Radiation dose with multi-detector row CT and digital angiography for diagnosis

被引:24
|
作者
Coche, Emmanuel
Vynckier, Stefaan
Octave-Prignot, Michelle
机构
[1] Univ Catholique Louvain, Clin Univ St Luc, Dept Med Imaging, B-1200 Brussels, Belgium
[2] Univ Catholique Louvain, Clin Univ St Luc, Dept Radiat Therapy, B-1200 Brussels, Belgium
关键词
D O I
10.1148/radiol.2402050580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare radiation dose delivered at four- and 16- detector row computed tomography ( CT) with a dose-modulation program and that delivered at digital angiography for evaluation of pulmonary embolism ( PE). Materials and Methods: The part of the study involving patients ( seven women, four men; mean age, 62 years +/- 16 [ standard deviation]; range, 41 - 85 years) was approved by the institutional review board. Patients gave written informed consent. Exposure was performed with an anthropomorphic phantom with thermoluminescent dosimeters for four - detector row CT without the dose-modulation program and 16- detector row CT without and with the dose-modulation program with standard protocols for pulmonary CT angiography ( 120 kV, 144 mAs, four and 16- detector rows with 1.00- and 0.75-mm section thickness, respectively). Digital angiograms were acquired with four standard projections at 80 kV. For digital angiography, radiation dose was calculated according to phantom measurements and adapted to acquisition and fluoroscopy times. Distribution of dose was compared for CT and digital angiography. Results: During pulmonary CT angiography, mean radiation dose delivered at middle of chest was 21.5, 19.5, and 18.2 mGy for four - detector row CT and for 16- detector row CT without and with dose-modulation program, respectively. At the same level, a mean dose of 91 mGy was delivered with digital angiography. The dose adjusted to clinical conditions was 139.0 mGy for digital angiography and could be reduced after technical adjustment. Ratios of maximum dose to mean dose were 1.15 and 2.96 for CT and digital angiography, respectively. With application of the dose-modulation program at 16- detector row CT, radiation dose was reduced 15%-20% at the upper chest. Conclusion: Multi - detector row CT delivers a lower radiation dose, with better spatial distribution of dose, than does pulmonary CT angiography. With 16- detector row CT and a dose-modulation program, radiation dose is decreased during PE work-up.
引用
收藏
页码:690 / 697
页数:8
相关论文
共 50 条
  • [1] Pulmonary Embolism: Radiation Dose with Multi-Detector Row CT and Digital Angiography for Diagnosis. (vol 240, pg 690, 2006)
    Coche, E.
    Vynckier, S.
    Octave-Prignot, M.
    [J]. RADIOLOGY, 2009, 251 (01)
  • [2] Multi-detector row CT: Radiation dose characteristics
    Hamberg, LM
    Rhea, JT
    Hunter, GJ
    Thrall, JH
    [J]. RADIOLOGY, 2003, 226 (03) : 762 - 772
  • [3] Diagnosis of venous thromboembolism by single-detector row and multi-detector row CT angiography
    Koyuncu, Abdullah
    Bozlar, Ugur
    Ustunsoz, Bahri
    Ors, Fatih
    Tasar, Mustafa
    Deniz, Omer
    Balkan, Arzu
    Somuncu, Ibrahim
    [J]. TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2007, 55 (01): : 24 - 33
  • [4] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    [J]. RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [5] Suspected acute pulmonary embolism: Evaluation with multi-detector row CT versus digital subtraction pulmonary arteriography
    Winer-Muram, HT
    Rydberg, J
    Johnson, MS
    Tarver, RD
    Williams, MD
    Shah, H
    Namyslowski, J
    Conces, D
    Jennings, SG
    Ying, J
    Trerotola, SO
    Kopecky, KK
    [J]. RADIOLOGY, 2004, 233 (03) : 806 - 815
  • [6] Pulmonary embolism: Optimization of small pulmonary artery visualization at multi-detector row CT
    Patel, S
    Kazerooni, EA
    Cascade, PN
    [J]. RADIOLOGY, 2003, 227 (02) : 455 - 460
  • [7] Clinical Prediction Scores For Pulmonary Embolism In The Era Of Multi-Detector Ct Angiography
    Siegel, N.
    Avila, N. A.
    Sun, J.
    Seam, N.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [8] CT angiography of pulmonary embolism using a 64 slice multi-detector scanner
    QIN Naishan JIANG Xuexiang QIU Jianxing ZHU Ying WANG Jichen Department of RadiologyPeking University First HospitalBeijingChina
    [J]. 中华医学杂志(英文版), 2009, (20) : 2509 - 2515
  • [9] CT angiography of pulmonary embolism using a 64 slice multi-detector scanner
    Qin Nai-shan
    Jiang Xue-xiang
    Qiu Jian-xing
    Zhu Ying
    Wang Ji-chen
    [J]. CHINESE MEDICAL JOURNAL, 2009, 122 (20) : 2509 - 2515
  • [10] Multi-detector row CT pulmonary angiography: Comparison of standard-dose and simulated low-dose techniques
    Tack, D
    De Maertelaer, V
    Petit, W
    Scillia, P
    Muller, P
    Suess, C
    Gevenois, PA
    [J]. RADIOLOGY, 2005, 236 (01) : 318 - 325