Automatic cable artifact removal for cardiac C-arm CT imaging

被引:1
|
作者
Haase, C. [1 ,4 ]
Schaefer, D. [1 ]
Kim, M. [2 ,3 ]
Chen, S. J. [2 ,3 ]
Carroll, J.
Eshuis, P. [5 ]
Doessel, O. [4 ]
Grass, M. [1 ]
机构
[1] Philips Res, D-22335 Hamburg, Germany
[2] Univ Colorado Denver, Dept Med, Aurora, CO 80045 USA
[3] Univ Colorado Denver, Dept Cardiol, Aurora, CO 80045 USA
[4] Karlsruhe Inst Technol, D-76131 Karlsruhe, Germany
[5] Philips Healthcare, Intervent X Ray, NL-5684 PC Best, Netherlands
关键词
X-ray imaging; Reconstruction; Artifact reduction; Segmentation; SEGMENTATION; ABLATION;
D O I
10.1117/12.2043488
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cardiac C-arm computed tomography (CT) imaging using interventional C-arm systems can be applied in various areas of interventional cardiology ranging from structural heart disease and electrophysiology interventions to valve procedures in hybrid operating rooms. In contrast to conventional CT systems, the reconstruction field of view (FOV) of C-arm systems is limited to a region of interest in cone-beam (along the patient axis) and fan-beam (in the transaxial plane) direction. Hence, highly X-ray opaque objects (e.g. cables from the interventional setup) outside the reconstruction field of view, yield streak artifacts in the reconstruction volume. To decrease the impact of these streaks a cable tracking approach on the 2D projection sequences with subsequent interpolation is applied. The proposed approach uses the fact that the projected position of objects outside the reconstruction volume depends strongly on the projection perspective. By tracking candidate points over multiple projections only objects outside the reconstruction volume are segmented in the projections. The method is quantitatively evaluated based on 30 simulated CT data sets. The 3D root mean square deviation to a reference image could be reduced for all cases by an average of 50 % (min 16 %, max 76 %). Image quality improvement is shown for clinical whole heart data sets acquired on an interventional C-arm system.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] First pass cable artefact correction for cardiac C-arm CT imaging
    Haase, C.
    Schaefer, D.
    Kim, M.
    Chen, S. J.
    Carroll, J. D.
    Eshuis, P.
    Doessel, O.
    Grass, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3861 - 3875
  • [2] CT Imaging with a mobile C-arm prototype
    Cheryauka, Arvi
    Tubbs, Dave
    Langille, Vinton
    Kalya, Prabhanjana
    Smith, Brady
    Cherone, Rocco
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [3] Metal Artifact Reduction for Clipping and Coiling in Interventional C-Arm CT
    Prell, D.
    Kyriakou, Y.
    Struffert, T.
    Doerfler, A.
    Kalender, W. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (04) : 634 - 639
  • [4] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [5] AUTOMATIC BONE REMOVAL FOR 3D LIVER TACE PLANNING WITH C-ARM CT
    Hansis, E.
    Radaelli, A.
    Noordhoek, N.
    Lorenz, C.
    Grass, M.
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1408 - 1411
  • [6] C-arm CT Perfusion Imaging in the Interventional Suite
    Fieselmann, Andreas
    Manhart, Michael
    [J]. CURRENT MEDICAL IMAGING, 2013, 9 (02) : 96 - 101
  • [7] Closed Sinusoid Trajectory for C-Arm CT Imaging
    Yang, Haiquan
    Li, Meihua
    Koizumi, Kazuhito
    Kudo, Hiroyuki
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3480 - 3484
  • [8] Coping with real world data: Artifact reduction and denoising for motion-compensated cardiac C-arm CT
    Taubmann, Oliver
    Maier, Andreas
    Hornegger, Joachim
    Lauritsch, Guenter
    Fahrig, Rebecca
    [J]. MEDICAL PHYSICS, 2016, 43 (02) : 883 - 893
  • [9] Method for Metal Artifact Avoidance in C-Arm Cone-Beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S. -F.
    Theodore, N.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [10] Artifact Reduction of Different Metallic Implants in Flat Detector C-Arm CT
    Hung, S. -C.
    Wu, C. -C.
    Lin, C. -J.
    Guo, W. -Y.
    Luo, C. -B.
    Chang, F. -C.
    Chang, C. -Y.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1288 - 1292