Closed Sinusoid Trajectory for C-Arm CT Imaging

被引:1
|
作者
Yang, Haiquan [1 ]
Li, Meihua [1 ]
Koizumi, Kazuhito [1 ]
Kudo, Hiroyuki [2 ]
机构
[1] Uni Hite Syst Corp, Dept Res & Dev, Kanagawa, Japan
[2] Univ Tsukuba, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki 305, Japan
关键词
computed tomography; cone-beam reconstruction; closed sinusoid; C-arm;
D O I
10.1109/NSSMIC.2006.353750
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we investigate cone-beam reconstruction for C-arm CT imaging using a closed sinusoid trajectory, which was firstly studied in [17] and can be considered a generalization of a saddle trajectory [7]. Inspired by the work in [10] and [13], we propose an exact shift-invariant filtered backprojection (FBP) reconstruction algorithm when the scanning trajectory is a closed sinusoid, or a perturbed closed sinusoid. We determine the filtering lines on the detector plane and give the steps to implement the algorithm for the planar detector geometry in a C-arm system. We also give two view independent reconstruction formulae for this geometry, both of which do not involve the view differencing operation and improve the reconstructed images by reducing discretization and sampling errors. The proposed algorithm is tested by simulation studies.
引用
收藏
页码:3480 / 3484
页数:5
相关论文
共 50 条
  • [1] On C-arm CT imaging with the extended line-ellipse-line trajectory
    Guo, Z.
    Lauritsch, G.
    Maier, A.
    Kugler, P.
    Islam, M.
    Vogt, F.
    Noo, F.
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [2] CT Imaging with a mobile C-arm prototype
    Cheryauka, Arvi
    Tubbs, Dave
    Langille, Vinton
    Kalya, Prabhanjana
    Smith, Brady
    Cherone, Rocco
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [3] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [4] C-arm CT Perfusion Imaging in the Interventional Suite
    Fieselmann, Andreas
    Manhart, Michael
    [J]. CURRENT MEDICAL IMAGING, 2013, 9 (02) : 96 - 101
  • [5] Respiratory Motion Compensation for C-Arm CT Liver Imaging
    Sindel, Aline
    Boegel, Marco
    Maier, Andreas
    Fahrig, Rebecca
    Hornegger, Joachim
    Doerfler, Arnd
    [J]. BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 221 - 226
  • [6] Automatic cable artifact removal for cardiac C-arm CT imaging
    Haase, C.
    Schaefer, D.
    Kim, M.
    Chen, S. J.
    Carroll, J.
    Eshuis, P.
    Doessel, O.
    Grass, M.
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [7] In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 6652 - 6659
  • [8] C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging
    Niu, K.
    Yang, P.
    Wu, Y.
    Struffert, T.
    Doerfler, A.
    Schafer, S.
    Royalty, K.
    Strother, C.
    Chen, G. -H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (07) : 1303 - 1309
  • [9] First pass cable artefact correction for cardiac C-arm CT imaging
    Haase, C.
    Schaefer, D.
    Kim, M.
    Chen, S. J.
    Carroll, J. D.
    Eshuis, P.
    Doessel, O.
    Grass, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3861 - 3875
  • [10] Evaluating the Feasibility of C-arm CT for Brain Perfusion Imaging: An in vitro Study
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    [J]. MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625