Exergy calculation and analysis of a dehumidification system using liquid desiccant

被引:36
|
作者
Zhang, Lun [1 ]
Liu, Xiaohua [1 ]
Jiang, Jingjing [1 ]
Jiang, Yi [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant dehumidification; Exergy; LiBr aqueous solution; System optimization; AIR-CONDITIONING SYSTEM; THERMODYNAMIC PROPERTIES; COOLING SYSTEM; ENERGY; REGENERATOR;
D O I
10.1016/j.enbuild.2013.11.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Liquid desiccant dehumidification is an effective method for extracting moisture from humid air and consumes less energy than conventional methods. Exergy is an essential tool to analyze liquid desiccant dehumidification systems. The problem with current exergy analysis of liquid desiccant dehumidification systems is that the exergy calculation for humid air is inconsistent with the exergy calculation for liquid desiccant. The choice of the dead state is the key issue in exergy analysis. In this paper, the saturated air state of ambient temperature is selected as the ultimate dead state. The ultimate dead state of liquid desiccant is defined by limitation of the infinitely diluted solution that will guarantee the uniqueness of the ultimate dead state in the system and address the previously mentioned inconsistency. The exergy flow in the liquid desiccant dehumidification cycle is also calculated (LiBr aqueous solution is used as an example), and exergy expressed per kilogram of dry air and per kilogram of solute can simplify the calculations. Exergy destruction, a measurement of irreversibility in the heat and mass transfer process, indicates the direction of system improvement. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:318 / 328
页数:11
相关论文
共 50 条
  • [1] Exergy Analysis of Liquid Desiccant Dehumidification System
    Xiong, Z. Q.
    Dai, Y. J.
    Wang, R. Z.
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2010, 7 (03) : 241 - 262
  • [2] Exergy analysis of liquid desiccant dehumidification and cooling system
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    [J]. Huagong Xuebao, 2008, SUPPL. (37-42):
  • [3] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    [J]. ENERGY, 2020, 204
  • [4] ANALYSIS OF AIR DEHUMIDIFICATION USING LIQUID DESICCANT SYSTEM
    ELSAYED, MM
    [J]. RENEWABLE ENERGY, 1994, 4 (05) : 519 - 528
  • [5] Exergy performance and thermodynamic properties of the ideal liquid desiccant dehumidification system
    Wang, Li
    Li, Nianping
    Zhao, Binwen
    [J]. ENERGY AND BUILDINGS, 2010, 42 (12) : 2437 - 2444
  • [6] Exergy analysis on optimal desiccant solution flow rate in heat exchanger for air dehumidification using liquid desiccant
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 128 : 129 - 138
  • [7] Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System
    Kavasogullari, Baris
    Cihan, Ertugrul
    Demir, Hasan
    [J]. TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2020, 14 (01): : 36 - 40
  • [8] EXPERIMENTAL ANALYSIS OF AIR DEHUMIDIFICATION SYSTEM WITH LIQUID DESICCANT
    Zhang, Li
    Chitose, Tanaka
    Hihara, Eiji
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 8, 2010, : 169 - 177
  • [9] Exergy analysis of dehumidification systems: A comparison between the condensing dehumidification and the desiccant wheel dehumidification
    Ge, Fenghua
    Wang, Cong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 224 (224)
  • [10] Cooling & dehumidification using liquid desiccant
    Rane, MV
    Reddy, SVK
    Bajaj, JS
    [J]. PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 414 - 418