Exergy analysis on optimal desiccant solution flow rate in heat exchanger for air dehumidification using liquid desiccant

被引:7
|
作者
Guan, Bowen [1 ]
Liu, Xiaohua [1 ]
Zhang, Tao [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci & Technol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Dehumidification; Liquid desiccant; Heat exchanger; Optimal solution flow rate; Exergy analysis; THERMODYNAMIC PROPERTIES; CONDITIONING SYSTEM; AQUEOUS-SOLUTIONS; PERFORMANCE; TEMPERATURE; ENTRANSY; LITHIUM; ENERGY; DRIVEN; LIBR;
D O I
10.1016/j.ijrefrig.2021.03.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat exchanger for air dehumidification using liquid desiccant is mainly composed of an air-solution heat exchanger (dehumidifier) and a solution-refrigerant heat exchanger, wherein there are three liquids, i.e., air, desiccant solution, and refrigerant. The same air dehumidification process can be achieved by different solution flow rates (m(s)). Limited studies have revealed which solution flow rate is optimal (m(s,opt)) for minimizing the exergy input of the heat exchanger (Ex(cooler)). Thus, the analytical solution for the effectiveness of the entire heat exchanger (epsilon) is theoretically deduced in this study, by the virtue of which, the m(s,opt) can be determined by solving partial derivative epsilon / partial derivative m(s) = 0. Results reveal that epsilon can be improved from 0.50 to 0.56 and Ex(cooler) can be saved by 17.9% in the given case, when the flow rate ratio of solution to air increases from 0.7 to the optimal value 1.5. Moreover, the air-solution-refrigerant flow rate matching plays an important role in the heat exchanger effectiveness. As a media fluid between the variable-temperature fluid (air) and the constant-temperature fluid (refrigerant), there is no solution flow rate to make the air-solution flow rate matching and solution-refrigerant flow rate matching simultaneously achieved. A compromised m(s,opt) should be pursued to balance the air-solution mismatching and the solution-refrigerant mismatching. It is anticipated that the findings of this research can be used for achieving an efficient air dehumidification process in the heat exchanger using liquid desiccant. (C) 2021 Elsevier Ltd and IIR. All rights reserved.
引用
下载
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [1] Exergy Analysis of Liquid Desiccant Dehumidification System
    Xiong, Z. Q.
    Dai, Y. J.
    Wang, R. Z.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2010, 7 (03) : 241 - 262
  • [2] Exergy calculation and analysis of a dehumidification system using liquid desiccant
    Zhang, Lun
    Liu, Xiaohua
    Jiang, Jingjing
    Jiang, Yi
    ENERGY AND BUILDINGS, 2014, 69 : 318 - 328
  • [3] ANALYSIS OF AIR DEHUMIDIFICATION USING LIQUID DESICCANT SYSTEM
    ELSAYED, MM
    RENEWABLE ENERGY, 1994, 4 (05) : 519 - 528
  • [4] Exergy analysis of liquid desiccant dehumidification and cooling system
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    Huagong Xuebao, 2008, SUPPL. (37-42):
  • [5] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    ENERGY, 2020, 204
  • [6] A high performance desiccant dehumidification unit using solid desiccant coated heat exchanger with heat recovery
    Zhao, Y.
    Dai, Y. J.
    Ge, T. S.
    Wang, H. H.
    Wang, R. Z.
    ENERGY AND BUILDINGS, 2016, 116 : 583 - 592
  • [7] Effect of desiccant adsorption isotherm on dehumidification performance of desiccant coated heat exchanger
    Yang T.
    Ge T.
    Huagong Xuebao/CIESC Journal, 2022, 73 (12): : 5367 - 5375
  • [8] EXPERIMENTAL ANALYSIS OF AIR DEHUMIDIFICATION SYSTEM WITH LIQUID DESICCANT
    Zhang, Li
    Chitose, Tanaka
    Hihara, Eiji
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 8, 2010, : 169 - 177
  • [9] An analytical solution for air dehumidification by liquid desiccant in a packed column
    Babakhani, Davoud
    Soleymani, Meysam
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (09) : 969 - 977
  • [10] Experimental analysis on chemical dehumidification of air by liquid desiccant and desiccant regeneration in a packed tower
    Longo, GA
    Gasparella, A
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 587 - 591