In-flight calibration of the Hitomi Soft X-ray Spectrometer. (2) Point spread function

被引:7
|
作者
Maeda, Yoshitomo [1 ,2 ]
Sato, Toshiki [3 ]
Hayashi, Takayuki [4 ,5 ]
Iizuka, Ryo [1 ]
Angelini, Lorella [4 ]
Asai, Ryota [3 ]
Furuzawa, Akihiro [6 ]
Kelley, Richard [4 ,7 ]
Koyama, Shu [1 ]
Kurashima, Sho [3 ]
Ishida, Manabu [1 ,2 ]
Mori, Hideyuki [4 ]
Nakaniwa, Nozomi [3 ]
Okajima, Takashi [4 ]
Serlemitsos, Peter J. [4 ]
Tsujimoto, Masahiro [1 ]
Yaqoob, Tahir [4 ,7 ]
机构
[1] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Chuo Ku, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2525210, Japan
[2] Grad Univ Adv Studies, Chuo Ku, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2525210, Japan
[3] Tokyo Metropolitan Univ, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan
[4] NASA, Goddard Space Flight Ctr, Code 916, Greenbelt, MD 20771 USA
[5] Nagoya Univ, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648602, Japan
[6] Fujita Hlth Univ, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi 4701192, Japan
[7] Univ Maryland Baltimore Cty, Dept Phys, 1000 Hilltop Circle, Baltimore, MD 21250 USA
关键词
space vehicles: instruments; techniques: imaging spectroscopy; telescopes;
D O I
10.1093/pasj/psx146
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We present results of inflight calibration of the point spread function of the Soft X-ray Telescope that focuses X-rays onto the pixel array of the Soft X-ray Spectrometer system. We make a full array image of a point-like source by extracting a pulsed component of the Crab nebula emission. Within the limited statistics afforded by an exposure time of only 6.9 ks and limited knowledge of the systematic uncertainties, we find that the raytracing model of 1.'2 half-power-diameter is consistent with an image of the observed event distributions across pixels. The ratio between the Crab pulsar image and the raytracing shows scatter from pixel to pixel that is 40% or less in all except one pixel. The pixel-to-pixel ratio has a spread of 20%, on average, for the 15 edge pixels, with an averaged statistical error of 17% (1 sigma). In the central 16 pixels, the corresponding ratio is 15% with an error of 6%.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] A novel, accurate-focusing X-ray spectrometer.
    Johansson, Tryggve
    ZEITSCHRIFT FUR PHYSIK, 1933, 82 (7-8): : 507 - 528
  • [42] On-ground calibration of the Hitomi Hard X-ray Telescopes
    Mori, Hideyuki
    Miyazawa, Takuya
    Awaki, Hisamitsu
    Matsumoto, Hironori
    Babazaki, Yasunori
    Bandai, Ayako
    Demoto, Tadatsugu
    Furuzawa, Akihiro
    Haba, Yoshito
    Hayashi, Takayuki
    Iizuka, Ryo
    Ishibashi, Kazunori
    Ishida, Manabu
    Ishida, Naoki
    Itoh, Masayuki
    Iwase, Toshihiro
    Kato, Hiroyoshi
    Kobayashi, Hiroaki
    Kosaka, Tatsuro
    Kunieda, Hideyo
    Krashima, Shou
    Kurihara, Daichi
    Kuroda, Yuuji
    Maeda, Yoshitomo
    Meshino, Yoshifumi
    Mitsuishi, Ikuyuki
    Miyata, Yuusuke
    Nagano, Housei
    Namba, Yoshiharu
    Ogasaka, Yasushi
    Ogi, Keiji
    Okajima, Takashi
    Saji, Shigetaka
    Shimasaki, Fumiya
    Sato, Takuro
    Sato, Toshiki
    Shima, Naotsugu
    Sugita, Satoshi
    Suzuki, Yoshio
    Tachibana, Kenji
    Tachibana, Sasagu
    Takizawa, Shun'ya
    Tamura, Keisuke
    Tawara, Yuzuru
    Tomikawa, Kazuki
    Torii, Tatsuharu
    Uesugi, Kentaro
    Yamashita, Koujun
    Yamauchi, Shigeo
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (01)
  • [43] Point spread function model for X-ray imaging
    Shao, Junming
    Lu, Hongnian
    Cai, Hui
    Guangxue Xuebao/Acta Optica Sinica, 2005, 25 (08): : 1148 - 1152
  • [44] Design and on-orbit operation of the soft x-ray spectrometer adiabatic demagnetization refrigerator on the Hitomi observatory
    Shirron, Peter John
    Kimball, Mark O.
    James, Bryan L.
    Muench, Theodore
    Canavan, Edgar R.
    DiPirro, Michael J.
    Bialas, Thomas A.
    Sneiderman, Gary A.
    Boyce, Kevin R.
    Kilbourne, Caroline Anne
    Porter, Frederick S.
    Fujimoto, Ryuichi
    Takei, Yoh
    Yoshida, Seiji
    Mitsuda, Kazuhisa
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (02)
  • [45] ITER-relevant calibration technique for soft x-ray spectrometer
    Rzadkiewicz, J.
    Ksiazek, I.
    Zastrow, K-D.
    Coffey, I. H.
    Jakubowska, K.
    Lawson, K. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [46] Calibration of energy response of detection elements for soft X-ray spectrometer
    Sun, Ke-Xu
    Yi, Rong-Qing
    Huang, Tian-Xuan
    Cui, Yan-Li
    Ding, Yong-Kun
    Yang, Jia-Min
    Zhang, Bao-Han
    Jiang, Shao-En
    Cui, Ming-Qi
    Zhu, Pei-Ping
    Zhao, Yi-Dong
    Li, Gang
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2001, 25 (05):
  • [47] Calibration of energy response of detection elements for soft X-ray spectrometer
    Sun, KX
    Yi, RQ
    Huang, TX
    Cui, YL
    Ding, YK
    Yang, JM
    Zhang, BH
    Jiang, SE
    Cui, MQ
    Zhu, PP
    Zhao, YD
    Li, G
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2001, 25 (05): : 448 - 454
  • [48] IN-FLIGHT ENERGY CALIBRATION FOR THE X-RAY AND GAMMA-RAY SPECTROMETERS ON THE SOLAR-A SATELLITE
    YOSHIMORI, M
    OKUDAIRA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (03): : 880 - 884
  • [49] The Hitomi X-Ray Observatory, Part 2
    Kelley, Richard L.
    Nakazawa, Kazuhiro
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (02)
  • [50] Calibration of the MESSENGER X-Ray Spectrometer
    Starr, Richard D.
    Schlemm, Charles E., II
    Ho, George C.
    Nittler, Larry R.
    Gold, Robert E.
    Solomon, Sean C.
    PLANETARY AND SPACE SCIENCE, 2016, 122 : 13 - 25