Diagnostic workup of primary sclerosing cholangitis: The benefit of adding gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography to conventional T2-weighted magnetic resonance cholangiography

被引:21
|
作者
Nolz, R. [1 ]
Asenbaum, U. [1 ]
Schoder, M. [1 ]
Wibmer, A. [1 ]
Einspieler, H. [1 ]
Prusa, A. M. [2 ]
Peck-Radosavljevic, M. [3 ]
Ba-Ssalamah, A. [1 ]
机构
[1] Med Univ Vienna, Div Gen & Pediat Radiol, Dept Biomed Imaging & Image Guided Therapy, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Surg, Div Vasc Surg, A-1090 Vienna, Austria
[3] Med Univ Vienna, Div Gastroenterol & Hepatol, Dept Internal Med 3, A-1090 Vienna, Austria
关键词
GD-EOB-DTPA; CONTRAST AGENT; LIVER-FUNCTION; HEPATOBILIARY PHASE; CLINICAL-EVALUATION; CHOLANGIOPANCREATOGRAPHY; MRI; TRANSPLANTATION; HEPATITIS; DISEASE;
D O I
10.1016/j.crad.2013.12.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the value of gadoxetic acid-enhanced T1-weighted (T1W) magnetic resonance cholangiography (MRC) versus conventional T2-weighted (T2W) MRC compared to endoscopic retrograde cholangiopancreatography (ERCP) in patients with primary sclerosing cholangitis (PSC). MATERIALS AND METHODS: Based on T1W MRC, PSC patients were classified into a regular (RG) and a delayed (DG) excreting group, with an absence of gadoxetic acid in the common bile duct at 20 min. Beading, pruning, and gradation of central bile duct stenosis, evaluated by T1W and T2W MRC, were compared to ERCP. Liver parenchymal enhancement was measured in both study groups and compared to a reference group (n = 20) without a history of liver disease. Two readers performed all measurements. RESULTS: Based on beading and pruning of the peripheral bile ducts, sensitivities, specificities, and accuracies for reader 1 were 0.17/0.43, 0/0.17, and 0.15/0.31 for T1W MRC, and 0.83/0.86,1/0.83, and 0.85/0.85 for T2W MRC (p = 0.004). For reader 2 sensitivities, specificities, and accuracies were 0.25/0.57, 0/0.33, and 0.23/0.46 for T1W MRC, and 0.92/1,1/0.83, and 0.92/0.92 for T2W MRC (p = 0.012). Compared to ERCP, central bile duct stenoses were significantly overestimated (p < 0.001) by T2W MRC. A significantly lower parenchymal enhancement was found in the DG (n = 7) compared to the RG (n = 13), and compared to the reference group (p < 0.001). CONCLUSION: The combined performance of T2W and T1W MRC may provide a comprehensive imaging workup of PSC, including morphological and functional information resulting in optimal management. (C) 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:499 / 508
页数:10
相关论文
共 50 条
  • [31] Coronary Plaque Characterization by T1-Weighted Cardiac Magnetic Resonance
    Botnar, Rene M.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2009, 2 (06) : 729 - 730
  • [32] Chemical design of nanoprobes for T1-weighted magnetic resonance imaging
    Peng, Yung-Kang
    Tsang, Shik Chi Edman
    Chou, Pi-Tai
    [J]. MATERIALS TODAY, 2016, 19 (06) : 336 - 348
  • [33] Value of T1-weighted Magnetic Resonance Imaging in Cholesteatoma Detection
    Fukuda, Atsushi
    Morita, Shinya
    Harada, Taisuke
    Fujiwara, Keishi
    Hoshino, Kimiko
    Nakamaru, Yuji
    Homma, Akihiro
    [J]. OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : 1440 - 1444
  • [34] Augmented T1-weighted steady state magnetic resonance imaging
    Ye, Yongquan
    Lyu, Jingyuan
    Hu, Yichen
    Zhang, Zhongqi
    Xu, Jian
    Zhang, Weiguo
    Yuan, Jianmin
    Zhou, Chao
    Fan, Wei
    Zhang, Xu
    [J]. NMR IN BIOMEDICINE, 2022, 35 (08)
  • [35] Hybrid Nanotrimers for Dual T1 and T2-Weighted Magnetic Resonance Imaging
    Cheng, Kai
    Yang, Meng
    Zhang, Ruiping
    Qin, Chunxia
    Su, Xinhui
    Cheng, Zhen
    [J]. ACS NANO, 2014, 8 (10) : 9884 - 9896
  • [36] Brain Extraction Method for T1-weighted Magnetic Resonance Scans
    Somasundaram, K.
    Kalaiselvi, T.
    [J]. 2010 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS (SPCOM), 2010,
  • [37] Associating T1-Weighted and T2-Weighted Magnetic Resonance Imaging Radiomic Signatures With Preoperative Symptom Severity in Patients With Cervical Spondylotic Myelopathy
    Alan, Nima
    Zenkin, Serafettin
    Lavadi, Raj Swaroop
    Legarreta, Andrew D.
    Hudson, Joseph S.
    Fields, Daryl P.
    Agarwal, Nitin
    Mamindla, Priyadarshini
    Zhang, Murat
    Peddagangireddy, Vishal
    Puccio, Lauren
    Buell, Thomas J.
    Hamilton, D. Kojo
    Kanter, Adam S.
    Okonkwo, David O.
    Zinn, Pascal O.
    Colen, Rivka R.
    [J]. WORLD NEUROSURGERY, 2024, 184 : E137 - E143
  • [38] Hepatocellular carcinoma with central scar on gadoxetic acid-enhanced and diffusion-weighted magnetic resonance imaging
    Han, Sol Bee
    Kim, Young Kon
    Min, Ji Hye
    Ha, Sang Yun
    Jeong, Woo Kyung
    Lee, Won Jae
    [J]. ACTA RADIOLOGICA, 2018, 59 (04) : 393 - 401
  • [39] Pretransplant Diagnosis of Hepatocellular Carcinoma by Gadoxetic Acid-Enhanced and Diffusion-Weighted Magnetic Resonance Imaging
    Hwang, Jiyoung
    Kim, Young Kon
    Kim, Jong Man
    Lee, Won Jae
    Choi, Dongil
    Hong, Seong Sook
    [J]. LIVER TRANSPLANTATION, 2014, 20 (12) : 1436 - 1446
  • [40] Publisher Correction: Prediction of malignant glioma grades using contrast-enhanced T1-weighted and T2-weighted magnetic resonance images based on a radiomic analysis
    Takahiro Nakamoto
    Wataru Takahashi
    Akihiro Haga
    Satoshi Takahashi
    Shigeru Kiryu
    Kanabu Nawa
    Takeshi Ohta
    Sho Ozaki
    Yuki Nozawa
    Shota Tanaka
    Akitake Mukasa
    Keiichi Nakagawa
    [J]. Scientific Reports, 10