Pressure drop of R134a and R1234ze(E) during condensation in horizontal microchannel arrays cooled symmetrically and asymmetrically

被引:7
|
作者
Wang, Ji [1 ]
Li, Jun Ming [1 ]
机构
[1] Tsinghua Univ, Dept Thermal Engn, Minist Educ, Key Lab Thermal Sci & Power Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Condensation; Pressure drop; Microchannel; Refrigerant; Symmetric and asymmetric cooling; INTERMITTENT FLOW REGIME; HEAT-TRANSFER; CIRCULAR MICROCHANNELS; VALIDATED MODEL; 2-PHASE FLOW; SMOOTH TUBES; AIR-WATER; PART; MINICHANNELS; R22;
D O I
10.1016/j.expthermflusci.2018.03.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation was conducted for pressure drop of R134a and R1234ze(E) condensing in horizontal oval microchannel arrays with a hydraulic diameter of 301.6 gm, an aspect ratio of 2.46 and a length of 50 mm. The refrigerant saturation temperatures of 31 degrees C, 37 degrees C, 41 degrees C and 45 degrees C, mass fluxes of 60, 120, 180, 250 kg/(m(2)s), qualities of 0.1-0.9 were taken into account and their effects on the frictional pressure drop were analyzed. Specially, the effects of microchannel arrays cooling methods, including symmetric cooling and asymmetric cooling, were studied. The frictional pressure drops of R134a and R1234ze(E) were compared. The results showed that the frictional pressure drop increases with increasing mass flux, inlet quality and cooling water inlet temperature, and decreases with increasing refrigerant saturation temperature. The frictional pressure drop under symmetric cooling is lower than that under asymmetric cooling. The frictional pressure drop of R134a is slightly lower than that of R1234ze(E) for higher mass fluxes and inlet qualities. Six available correlations in the literature were used to predict the present data. All the correlations underestimated the data with the correlation given by Cavallini et al. (2002) having the lowest prediction error.
引用
收藏
页码:266 / 283
页数:18
相关论文
共 50 条
  • [31] Experimental study on condensation heat transfer and pressure drop in horizontal smooth tube for R1234ze(E), R32 and R410A
    Hossain, Md. Anowar
    Onaka, Yoji
    Miyara, Akio
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2012, 35 (04) : 927 - 938
  • [32] Experimental and Numerical Studies on an Automobile Air Conditioning System With the Refrigerants R134a, R1234yf, and R1234ze(E)
    Gurudatt, H. M.
    Narasimham, G. S. V. L.
    Sadashive Gowda, B.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (01)
  • [33] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Li, Shizhen
    Liu, Yingxin
    Liu, Yanjun
    Zhang, Jingzhi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (40) : 57166 - 57182
  • [34] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Shizhen Li
    Yingxin Liu
    Yanjun Liu
    Jingzhi Zhang
    Environmental Science and Pollution Research, 2021, 28 : 57166 - 57182
  • [35] Heat transfer coefficient, pressure drop, and flow patterns of R1234ze(E) evaporating in microchannel tube
    Li, Houpei
    Hrnjak, Pega
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 138 (1368-1386) : 1368 - 1386
  • [36] Theoretical and experimental study of wavy flow during R134a condensation flow in symmetrically and asymmetrically cooled microchannels
    Wang, Ji
    Li, Jun Ming
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2018, 101 : 125 - 136
  • [37] R1234yf and R1234ze(E) as environmentally friendly replacements of R134a: Assessing flow boiling on an experimental basis
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 336 - 346
  • [38] Performance evaluation of VCR system with pure and various blends of R134a, R1234yf, and R1234ze (E) refrigerants
    Kuwar, Yogendra Vasantrao
    HEAT TRANSFER, 2024, 53 (06) : 2879 - 2904
  • [39] First experimental results of the use of R1234yf and R1234ze(E) as drop-in substitutes for R134a in a water-to-water heat pump
    Molinaroli, L.
    Lucchini, A.
    Colombo, L. P. M.
    Bocchinfuso, F.
    37TH UIT HEAT TRANSFER CONFERENCE, 2020, 1599
  • [40] Saturated vapour condensation of R134a inside a 4 mm ID horizontal smooth tube: Comparison with the low GWP substitutes R152a, R1234yf and R1234ze(E)
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 133 : 461 - 473