PERFORMANCE OF GAS PHASE FILTERS - FULL SCALE TEST FACILITY

被引:0
|
作者
Haghighat, Fariborz [1 ]
Bastani, Arash [1 ]
Lee, Chang-Seo
Lakdawala, Ness
Flaherty, Chris
机构
[1] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, Canada
关键词
Ventilation; Air purification; Filtration; Activated charcoal carbon; Testing;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Improving indoor air quality (IAQ) has received considerable attention over the past few decades. Applying air cleaning devices to filter particulates and gaseous contaminants is an effective way to reduce the contaminant levels and have a positive influence on the IAQ. Also, from an energy perspective, this method can be more efficient than diluting the indoor air with excessive outdoor air under certain conditions, i.e., contaminated outdoor air, hot and humid or extremely cold weathers. However, there is a lack of an acceptable approach to evaluate the performance of complete gaseous filtering systems for building applications. A full scale test facility was designed and constructed to investigate the removal effectiveness of commercial gas-phase air cleaning devices. The test rig was verified by conducting the system pre-qualification tests similar to those of ASHRAE standard 52.2. The tests were designed to quantitatively verify the reliability of the test rig for gas filter testing like velocity uniformity, uniform dispersion of challenge contaminants, temperature and humidity control. As a final validation, a commercial gas filter was tested for toluene removal. This paper presents the details of the design and prequalification tests of the developed test rig as well as the experimental results of a v-shape module filled with a coconut shell-based granular activated carbon.
引用
收藏
页码:1015 / 1022
页数:8
相关论文
共 50 条
  • [1] A FULL SCALE, VSTOL, GROUND ENVIRONMENT TEST FACILITY
    REED, LHK
    NINTH INTERNATIONAL SYMPOSIUM ON AIR BREATHING ENGINES, VOLS 1 AND 2: SYMPOSIUM PAPERS, 1989, : 1228 - 1234
  • [2] FULL SCALE TEST FACILITY COMPLETED FOR NUCLEAR-REACTOR WETWELL
    不详
    POWER ENGINEERING, 1978, 82 (07) : 110 - 110
  • [3] A FACILITY FOR PERFORMANCE EVALUATION OF FULL-SIZE CHARCOAL FILTERS IN REMOVING RADIOIODINE
    MINER, D
    FLETCHER, WD
    KITZES, AS
    TAYLOR, GR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, S 10 : 1 - &
  • [4] A Gas Turbine Test Facility of Blade Aerothermal Performance
    Bai, Bo
    Dong, Yuxuan
    Li, Zhigang
    Li, Jun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (04): : 987 - 993
  • [5] Numerical calculations of wind flow in a full-scale wind test facility
    Oh, CH
    Lacy, JM
    WIND ENGINEERING INTO THE 21ST CENTURY, VOLS 1-3, 1999, : 1315 - 1319
  • [6] A Full-Scale Tidal Blade Fatigue Test using the FastBlade Facility
    Dubon, Sergio Lopez
    Vogel, Christopher
    Cava, David Garcia
    Cuthill, Fergus
    McCarthy, Edward D.
    Bradaigh, Conchur M. O.
    RENEWABLE ENERGY, 2024, 228
  • [7] CLADDING PERFORMANCE ON A FULL SCALE TEST FRAME.
    Wang, Marcy Li
    Earthquake Spectra, 1987, 3 (01) : 119 - 173
  • [8] Performance test of indoor environment in full scale chamber
    Lee, JK
    Han, SW
    Park, JS
    Baik, YK
    Sohn, FY
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 837 - 840
  • [9] Development of Full-Scale Reflective Cracking Test at the FAA National Airport Pavement Test Facility
    Yin, Hao
    Barbagallo, Donald
    TRANSPORTATION RESEARCH RECORD, 2013, (2368) : 81 - 91
  • [10] 2-PHASE FLOW IN A FULL-SCALE LOOP SEAL FACILITY
    TUOMISTO, H
    KAJANTO, P
    NUCLEAR ENGINEERING AND DESIGN, 1988, 107 (03) : 295 - 305