Technical Report: TG-142 compliant and comprehensive quality assurance tests for respiratory gating

被引:18
|
作者
Woods, Kyle [1 ]
Rong, Yi [2 ]
机构
[1] Ohio State Univ, Dept Radiat Oncol, Columbus, OH 43210 USA
[2] Univ Calif Davis, Dept Radiat Oncol, Ctr Comprehens Canc, Sacramento, CA 95817 USA
关键词
respiratory gating; temporal accuracy; time delays; real-time position management; calibration of surrogate; GATED RADIATION-THERAPY; RADIOTHERAPY; MOTION; DELIVERY; ONCOLOGY; SYSTEM; DELAYS;
D O I
10.1118/1.4932363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and establish a comprehensive gating commissioning and quality assurance procedure in compliance with TG-142. Methods: Eight Varian TrueBeam Linacs were used for this study. Gating commissioning included an end-to-end test and baseline establishment. The end-to-end test was performed using a CIRS dynamic thoracic phantom with a moving cylinder inside the lung, which was used for carrying both optically simulated luminescence detectors (OSLDs) and Gafchromic EBT2 films while the target is moving, for a point dose check and 2D profile check. In addition, baselines were established for beam-on temporal delay and calibration of the surrogate, for both megavoltage (MV) and kilovoltage (kV) beams. A motion simulation device (MotionSim) was used to provide periodic motion on a platform, in synchronizing with a surrogate motion. The overall accuracy and uncertainties were analyzed and compared. Results: The OSLD readings were within 5% compared to the planned dose (within measurement uncertainty) for both phase and amplitude gated deliveries. Film results showed less than 3% agreement to the predicted dose with a standard sinusoid motion. The gate-on temporal accuracy was averaged at 139 +/- 10 ms for MV beams and 92 +/- 11 ms for kV beams. The temporal delay of the surrogate motion depends on the motion speed and was averaged at 54.6 +/- 3.1 ms for slow, 24.9 +/- 2.9 ms for intermediate, and 23.0 +/- 20.1 ms for fast speed. Conclusions: A comprehensive gating commissioning procedure was introduced for verifying the output accuracy and establishing the temporal accuracy baselines with respiratory gating. The baselines are needed for routine quality assurance tests, as suggested by TG-142. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:6488 / 6497
页数:10
相关论文
共 40 条
  • [1] TG-142: Quality Assurance for Medical Accelerators
    Klein, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] TG142 Complied Comprehensive Commissioning and Quality Assurance Procedure for Respiratory Gating
    Woods, K.
    Rong, Y.
    Weldon, M.
    Gupta, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 386 - 386
  • [3] A Practical Solution to the Recommendations of TG-142 for a Respiratory Gating Program
    Cirino, E.
    Iftimia, I.
    Halvorsen, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Automating AAPM TG-142 Quality Assurance Tests Using XML and Python']Python Scripts
    LeMerise, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E487 - E487
  • [6] Use of Freeware Business Intelligence Software to Trend TG-142 Compliant Linac QA Parameters
    Ayan, A.
    DiCostanzo, D.
    Woollard, J.
    Gupta, N.
    MEDICAL PHYSICS, 2016, 43 (06) : 3367 - 3368
  • [7] A Clinical Evaluation of An Open-Source Toolkit for TG-142 Based Monthly Imaging Quality Assurance Via Comparison with Commercial Software
    Jayarathna, S.
    Howard, S.
    Johnson, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Sensitivity Testing of Quality Assurance (QA) Tasks in Sun Nuclear Corporation (SNC) Machine - A Fully Automated TG-142 QA Solution
    Martin, G.
    Willet, A.
    Gilmore, M.
    Howard, L.
    Elmer, S.
    Clements, R.
    Biggar, R.
    Rowbottom, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E312 - E313
  • [9] Quality Assurance of respiratory gating with Hexamotion system
    Sardo, Anna
    Padula, Nicola
    Bosticardo, Giorgio
    Pugliatti, Cristina
    Baroni, Simone
    Frassinelli, Luca
    Petrucci, Rachele
    Franza, Nicola
    Reali, Alessia
    Lucio, Francesco
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3358 - S3360
  • [10] AAPM Task Group 198 Report: An implementation guide for TG 142 quality assurance of medical accelerators
    Hanley, Joseph
    Dresser, Sean
    Simon, William
    Flynn, Ryan
    Klein, Eric E.
    Letourneau, Daniel
    Liu, Chihray
    Yin, Fang-Fang
    Arjomandy, Bijan
    Ma, Lijun
    Aguirre, Francisco
    Jones, Jimmy
    Bayouth, John
    Holmes, Todd
    MEDICAL PHYSICS, 2021, 48 (10) : E830 - E885