New 2-D dosimetric technique for radiotherapy based on planar thermoluminescent detectors

被引:31
|
作者
Olko, P.
Marczewska, B.
Czopyk, L.
Czermak, M. A.
Klosowski, M.
Waligorski, M. P. R.
机构
[1] PAN, Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Ctr Oncol, PL-31115 Krakow, Poland
关键词
D O I
10.1093/rpd/ncl019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
At the Institute of Nuclear Physics of the Polish Academy of Sciences (IFJ) in Krakow, a two-dimensional (2-D) thermo-luminescence (TL) dosimetry system was developed within the MAESTRO (Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology) 6 Framework Programme and tested by evaluating 2-D dose distributions around radioactive sources. A thermoluminescent detector (TLD) foil was developed, of thickness 0.3 into and diameter 60 mm, containing a mixture of highly sensitive LiF:Mg,Cu,P powder and Ethylene TetraFluoroEthylene (ETFE) polymer. Foil detectors were irradiated with Ra-266 brachytherapy sources and a Sr-90/Y-90 source. 2-D dose distributions were evaluated using a prototype planar (diameter 60 mm) reader, equipped with a 12 bit Charge Coupled Devices (CCD) PCO AG camera, with a. p resolution of 640 x 480 pixels. The new detectors, showing a spatial resolution better than 0.5 rum and a measurable dose range typical for radiotherapy, can find many applications in clinical dosimetry. Another technology applicable to clinical dosimetry, also developed at IFJ, is the Si microstrip detector of size 95 x 95 into, which may be used to evaluate the dose distribution with a spatial resolution of 120 pm along one direction, in real-time mode. The microstrip and TLD technology will be further improved, especially to develop detectors of larger area, and to make them applicable to some advanced radiotherapy modalities, such as intensity modulated radiotherapy (IMRT) or proton radiotherapy.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [31] A 2-D vector excitation coding technique
    Memon, N
    SIGNAL PROCESSING, 1998, 67 (02) : 163 - 172
  • [32] New cumulant based method for 2-D DOAs estimation
    School of Electronic Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China
    Dianzi Keji Diaxue Xuebao, 2008, 6 (840-843):
  • [33] A new facial expression recognition technique using 2-D DCT and neural networks based decision tree
    Xiao, Yegui
    Ma, L.
    Khorasani, K.
    2006 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORK PROCEEDINGS, VOLS 1-10, 2006, : 2421 - +
  • [34] Simulations of 2-D Materials-Based Field Effect Transistors for Quantum Cascade Detectors
    Cannavo, Emmanuele
    Marian, Damiano
    Marin, Enrique Gonzalez
    Tredicucci, Alessandro
    Fiori, Gianluca
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2024, 71 (01) : 630 - 636
  • [35] Dosimetric evaluation of a 2D multidetector dedicated to stereotactic radiotherapy
    Villeneuve, R.
    Cardon, T.
    Allegrini, O.
    Garnier, N.
    Amblard, R.
    Serrano, B.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S692 - S692
  • [36] 2-D FOCON arrays and their application in displays and planar illuminators
    Andrew, Putilin N.
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2008, 16 (08) : 819 - 823
  • [37] Point Contacts in Modeling Conducting 2-D Planar Structures
    Thiel, David V.
    Shahpari, Morteza
    Hettenhausen, Jan
    Lewis, Andrew
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2015, 14 : 978 - 981
  • [38] A 2-D block decomposition technique for designing 2-D FIR filters from frequency samples
    Angelidis, E
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (04) : 1096 - 1100
  • [39] 2-D dosimetry of a proton radiotherapy beam using large-area LiF: Mg,Cu,P TL detectors
    Czopyk, L.
    Cirrone, G. A. P.
    Cuttone, G.
    Klosowski, M.
    Olko, P.
    Sroka, U.
    Waligorski, M. P. R.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 977 - 980
  • [40] 2-D block decomposition technique for designing 2-D FIR filters from frequency samples
    Ministry of Natl Defense, Athens, Greece
    IEEE Trans Signal Process, 4 (1096-1100):