Ablation of tissue volumes using high intensity focused ultrasound

被引:96
|
作者
Malcolm, AL [1 ]
terHaar, GR [1 ]
机构
[1] ROYAL MARSDEN HOSP,INST CANC RES,JOINT DEPT PHYS,SUTTON SM2 5PT,SURREY,ENGLAND
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1996年 / 22卷 / 05期
基金
英国医学研究理事会;
关键词
ultrasound surgery; therapy; hyperthermia; cancer;
D O I
10.1016/0301-5629(96)00020-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Successful application of high intensity focused ultrasound to cancer treatment requires complete ablation of tissue volumes. In order to destroy an entire tumour it is necessary to place a contiguous array of touching lesions throughout it. In a study of how best to achieve this, exposures were selected to give single lesions that were thermal in origin, while avoiding effects due to tissue water boiling and acoustic cavitation. Arrays were formed in excised bovine liver. Under some exposure conditions, lesions were found to merge in front of the focal point, and failed to cover the desired volume. Using fine wire manganin-constantan thermocouples, temperature studies revealed a substantial rise in the temperature of surrounding untreated tissue. Cooling curves showed that it was necessary to allow surrounding tissue to cool for up to 2 min before ambient temperature was reached. By allowing the tissue to cool between exposures it was possible to form arrays of overlapping lesions, thus successfully ablating the complete target region.
引用
收藏
页码:659 / 669
页数:11
相关论文
共 50 条
  • [21] Multiple high-intensity focused ultrasound probes for kidney-tissue ablation
    Häcker, A
    Chauhan, S
    Peters, K
    Hildenbrand, R
    Marlinghaus, E
    Alken, P
    Michel, MS
    JOURNAL OF ENDOUROLOGY, 2005, 19 (08) : 1036 - 1040
  • [22] Non-invasive tissue ablation of kidney tumors by high intensity focused ultrasound
    Axel, H
    Stephan, MM
    Thomas, K
    Ernst, M
    Peter, A
    Uwe, KK
    JOURNAL OF UROLOGY, 2003, 169 (04): : 174 - 174
  • [23] TISSUE ABLATION IN BENIGN PROSTATIC HYPERPLASIA WITH HIGH-INTENSITY FOCUSED ULTRASOUND - REPLY
    MADERSBACHER, S
    KRATZIK, C
    SUSANI, M
    MARBERGER, M
    JOURNAL OF UROLOGY, 1994, 152 (06): : 1961 - 1961
  • [24] Cardiac ablation by transesophageal high intensity focused ultrasound
    JIANG ChenxiYU Ronghui and MA Changsheng Department of CardiologyAtrial Fibrillation CenterBeijing Anzhen HospitalCapital Medical UniversityBeijing China
    中华医学杂志(英文版), 2010, (17) : 2451 - 2453
  • [25] Cardiac ablation by transesophageal high intensity focused ultrasound
    Jiang Chen-xi
    Yu Rong-hui
    Ma Chang-sheng
    CHINESE MEDICAL JOURNAL, 2010, 123 (17) : 2451 - 2453
  • [26] Tissue Atomization by High Intensity Focused Ultrasound
    Simon, Julianna
    Sapozhnikov, Oleg
    Khokhlova, Vera
    Wang, Yak-Nam
    Crum, Lawrence
    Bailey, Michael
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1003 - 1006
  • [27] Multiple versus single ultrasound probes for tissue ablation by high intensity focused ultrasound: An experimental investigation
    Axel, H
    Stephan, MM
    Thomas, K
    Peter, A
    Kai-Uwe, K
    Sunita, C
    JOURNAL OF UROLOGY, 2003, 169 (04): : 208 - 208
  • [28] Tissue ablation using high-intensity focused ultrasound in the fetal sheep model: Potential for fetal treatment
    Paek, BW
    Vaezy, S
    Fujimoto, V
    Bailey, M
    Albanese, CT
    Harrison, MR
    Farmer, DL
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (03) : 702 - 705
  • [29] In vitro ablation of cardiac valves using high-intensity focused ultrasound
    Otsuka, R
    Fujikura, K
    Hirata, K
    Pulerwitz, T
    Oe, Y
    Suzuki, T
    Sciacca, R
    Marboe, C
    Wang, J
    Burkhoff, D
    Muratore, R
    Lizzi, FL
    Homma, S
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 109 - 114
  • [30] Extracardiac ablation of the atrioventricular junction in canines using high intensity focused ultrasound
    Strickberger, SA
    Takano, T
    Kluiwstra, JUA
    Abrams, G
    Morady, F
    Cain, C
    CIRCULATION, 1997, 96 (08) : 120 - 120