Oligonucleotide analysis with MALDI-ion-mobility-TOFMS

被引:58
|
作者
Koomen, JM
Ruotolo, BT
Gillig, KJ
McLean, JA
Russell, DH [1 ]
Kang, MJ
Dunbar, KR
Fuhrer, K
Gonin, M
Schultz, JA
机构
[1] Texas A&M Univ, Lab Biol Mass Spectrometry, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Chem, College Stn, TX 77843 USA
[3] Ionwerks Inc, Houston, TX USA
关键词
ion mobility; oligonucleotides; sequencing; DNA modifications; cisplatin;
D O I
10.1007/s00216-002-1363-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Matrix-assisted laser-desorption ionization followed by ion-mobility separation and time-of-flight mass analysis (MALDI-IM-TOFMS) has been used to characterize native and chemically modified DNA oligonucleotides up to eight bases in length. Mobility resolution between 20 and 30 can be used to separate oligonucleotides of different length, but not to differentiate between isomers or even different compositions of the same length. MALDI-IM-TOFMS does, however, have additional utility in the analysis of mixtures of DNA oligonucleotides and peptides, because these classes of molecules can be distinguished on the basis of differences in their mobility. Oligonucleotide sequencing is also possible by MALDI-IM-TOFMS. Ion signals corresponding to nucleobase losses, w-type, and y-type fragments were identified by use of differences in ion mobility. MALDI-IM-TOFMS was also used to resolve DNA-platinum adducts from the corresponding unmodified oligonucleotides.
引用
下载
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [31] Optimization of a modified aerospray deposition device for the preparation of samples for quantitative analysis by MALDI-TOFMS
    Holcomb, April
    Owens, Kevin G.
    ANALYTICA CHIMICA ACTA, 2010, 658 (01) : 49 - 55
  • [32] MALDI-TOFMS analysis of coordination and organometallic complexes: a nic(h)e area to work in
    Wyatt, Mark F.
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (07): : 712 - 719
  • [33] Factors governing the solubilization of phosphopeptides retained on ferric NTA IMAC beads and their analysis by MALDI TOFMS
    Hart, SR
    Waterfield, MD
    Burlingame, AL
    Cramer, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (09) : 1042 - 1051
  • [34] Influence of sample preparation method and silver salt types on MALDI-TOFMS analysis of polybutadiene
    Sung-Seen Choi
    Sung-Ho Ha
    Macromolecular Research, 2008, 16 : 108 - 112
  • [35] Statistical approach to understand MALDI-TOFMS matrices: Discovery and evaluation of new MALDI matrices
    Meier, Michael A. R.
    Adams, Nico
    Schubert, Ulrich S.
    ANALYTICAL CHEMISTRY, 2007, 79 (03) : 863 - 869
  • [36] Screening of nerve agent degradation products by MALDI-TOFMS
    Shu, You-Ren
    Su, An-Kai
    Liu, Ju-Tsung
    Lin, Cheng-Huang
    ANALYTICAL CHEMISTRY, 2006, 78 (13) : 4697 - 4701
  • [37] Screening of DHFR-binding drugs by MALDI-TOFMS
    Hannewald, Paul
    Maunit, Benoit
    Muller, Jean-Francois
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (7-8) : 1335 - 1344
  • [38] Resolving isomeric peptide mixtures: A combined HPLC/ion mobility-TOFMS analysis of a 4000-component combinatorial library
    Barnes, CAS
    Hilderbrand, AE
    Valentine, SJ
    Clemmer, DE
    ANALYTICAL CHEMISTRY, 2002, 74 (01) : 26 - 36
  • [39] MALDI matrix cluster ions as internal references for ion mobility measurements
    Mwangi, Joseph N.
    Todd, Daniel A.
    Chiu, Norman H. L.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2020, 23 (02) : 61 - 67
  • [40] MALDI-TOFMS Imaging Measurement of Synthesized Organic Components
    Sato, Koji
    Yoshida, Kazuyuki
    Morinaga, Hiroko
    Yamaguchi, Ryo
    Ogawa, Kiyoshi
    BUNSEKI KAGAKU, 2014, 63 (06) : 533 - 538