Regularized discriminant analysis for breast mass detection on full field digital mammograms

被引:0
|
作者
Wei, Jun [1 ]
Sahiner, Berkman [1 ]
Zhang, Yiheng [1 ]
Chan, Heang-Ping [1 ]
Hadjiiski, Lubomir M. [1 ]
Zhou, Chuan [1 ]
Ge, Jun [1 ]
Wu, Yi-Ta [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
computer-aided detection; full field digital mammogram; mass detection; regularized discriminant analysis; feature selection;
D O I
10.1117/12.654897
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
in computer-aided detection (CAD) applications, an important step is to design a classifier for the differentiation of the abnormal from the normal structures. We have previously developed a stepwise linear discriminant analysis (LDA) method with simplex optimization for this purpose. In this study, our goal was to investigate the performance of a regularized discriminant analysis (RDA) classifier in combination with a feature selection method for classification of the masses and normal tissues detected on full field digital mammograms (FFDM). The feature selection scheme combined a forward stepwise feature selection process and a backward stepwise feature elimination process to obtain the best feature subset. An RDA classifier and an LDA classifier in combination with this new feature selection method were compared to an LDA classifier with stepwise feature selection. A data set of 130 patients containing 260 mammograms; with 130 biopsy-proven masses was used. All cases had two mammographic views. The true locations of the masses were identified by experienced radiologists. To evaluate the performance of the classifiers, we randomly divided the data set into two independent sets of approximately equal size for training and testing. The training and testing were performed using the 2-fold cross validation method. The detection performance of the CAD system was assessed by free response receiver operating characteristic (FROC) analysis. The average test FROC curve was obtained by averaging the FP rates at the same sensitivity along the two corresponding test FROC curves from the 2-fold cross validation. At the case-based sensitivities of 90%, 80% and 70% on the test set, our RDA classifier with the new feature selection scheme achieved an FP rate of 1.8, 1.1, and 0.6 FPs/image, respectively, compared to 2.1, 1.4, and 0.8 FPs/image with stepwise LDA with simplex optimization. Our results indicate that RDA in combination with the sequential forward inclusion-backward elimination feature selection method can improve the performance of mass detection on mammograms. Further work is underway to optimize the feature selection and classification scheme and to evaluate if this approach can be generalized to other CAD classification tasks.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Study of Adaptability of Breast Density Analysis System Developed for Screen Film Mammograms (SFMs) to Full-Field Digital Mammograms (FFDMs): Robustness of Parenchymal Texture Analysis
    Wei, Jun
    Chan, Heang-Ping
    Helvie, Mark A.
    Zhou, Chuan
    Hadjiiski, Lubomir M.
    MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963
  • [32] Breast mass contour segmentation algorithm in digital mammograms
    Berber, Tolga
    Alpkocak, Adil
    Balci, Pinar
    Dicle, Oguz
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 110 (02) : 150 - 159
  • [33] Comparison of Tilt Correction Methods in Full Field Digital Mammograms
    Kallenberg, Michiel
    Karssemeijer, Nico
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 191 - 196
  • [34] Artificial-intelligence-driven breast density assessment in the transition from full-field digital mammograms to digital breast tomosynthesis
    Anant, Krisha
    Lopez, Juanita Hernandez
    Bennett, Debbie
    Gastounioti, Aimilia
    CANCER RESEARCH, 2024, 84 (03)
  • [35] Enhanced Accuracy of Breast Cancer Detection in Digital Mammograms using Wavelet Analysis
    Padmanabhan, Sharanya
    Sundararajan, Raji
    2012 INTERNATIONAL CONFERENCE ON MACHINE VISION AND IMAGE PROCESSING (MVIP), 2012, : 153 - 156
  • [36] A Deep Learning Approach to Re-create Raw Full-Field Digital Mammograms for Breast Density and Texture Analysis
    Shu, Hai
    Chiang, Tingyu
    Wei, Peng
    Do, Kim-Anh
    Lesslie, Michele D.
    Cohen, Ethan O.
    Srinivasan, Ashmitha
    Moseley, Tanya W.
    Sen, Lauren Q. Chang
    Leung, Jessica W. T.
    Dennison, Jennifer B.
    Hanash, Sam M.
    Weaver, Olena O.
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2021, 3 (04)
  • [37] A New GLLD Operator for Mass Detection in Digital Mammograms
    Gargouri, N.
    Masmoudi, A. Dammak
    Masmoudi, D. Sellami
    Abid, R.
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2012, 2012 (2012)
  • [38] Breast composition measurements from Full-Field Digital Mammograms using generative adversarial networks
    Garcia, E.
    Llado, X.
    Mann, R. M.
    Osuala, R.
    Marti, R.
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [39] Estimating breast density using a volumetric technique and full-field digital mammograms - Preliminary results
    Bloomquist, A
    Augustine, B
    Pawluczyk, O
    Mawdsley, GE
    Yaffe, MJ
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 705 - 712
  • [40] A deep learning method for volumetric breast density estimation from processed Full Field Digital Mammograms
    Vanegas, Doiriel C.
    Birhanu, Mahlet A.
    Karssemeijer, Nico
    Gubern-Merida, Albert
    Kallenberg, Michiel
    MEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS, 2019, 10950