Flow visualization in a centrifugal blood pump with an eccentric inlet port

被引:8
|
作者
Yamane, T
Kodama, T
Yamamoto, Y
Shinohara, T
Nosé, Y
机构
[1] Natl Inst Adv Ind Sci & Technol, Inst Human Sci & Biomed Engn, Tsukuba, Ibaraki 3058564, Japan
[2] Tokyo Univ Sci, Chiba, Japan
[3] Miwatec Co Ltd, Kanagawa, Japan
[4] Baylor Coll Med, Houston, TX 77030 USA
关键词
centrifugal pump; flow visualization; eccentric inlet port; shear rate;
D O I
10.1111/j.1525-1594.2004.07290.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow visualization analysis was applied to the Baylor/Miwatec centrifugal artificial heart to evaluate its fluid dynamic characteristics regarding antithrombogenicity. An eccentric vortex was found both in the upper and the lower gaps of the impeller, which is supposed to be caused by the eccentric inlet port. Therefore, one-way flow toward the outlet is formed and washes the pivot. The combination of an eccentric vortex and a pivot bearing that is washed is unique to the Baylor/Miwatec pump. For the male pivots exposed to periodic wash, the minimum shear rate around the bottom pivot was estimated to be 650/s, which is higher than the threshold for thrombus formation shown by other studies. The wall shear rate at the impeller bottom surface was found to be larger in the top contact mode than in the bottom contact mode.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [21] Shear evaluation by quantitative flow visualization near the casing surface of a centrifugal blood pump
    Nishida, M
    Yamane, T
    Tsukamoto, Y
    Ito, K
    Konishi, Y
    Masuzawa, T
    Tsukiya, T
    Endo, S
    Taenaka, Y
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2002, 45 (04) : 981 - 988
  • [22] Quantitative visualization study of flow in a scaled-up model of a centrifugal blood pump
    Ikeda, T
    Yamane, T
    Orita, T
    Tateishi, T
    ARTIFICIAL ORGANS, 1996, 20 (02) : 132 - 138
  • [23] Noninvasive pump flow estimation of a centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Nakatani, T
    Tatsumi, E
    Nishimura, T
    Takewa, Y
    Ohno, T
    Takano, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 651 - 654
  • [24] Effects of gravity on flow rate estimations of a centrifugal blood pump using the eccentric position of a levitated impeller
    Shida, Shuya
    Masuzawa, Toru
    Osa, Masahiro
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (12): : 774 - 781
  • [25] Cavitation performance and flow characteristic in a centrifugal pump with inlet guide vanes
    Tan, L.
    Zha, L.
    Cao, S. L.
    Wang, Y. C.
    Gui, S. B.
    INTERNATIONAL SYMPOSIUM OF CAVITATION AND MULTIPHASE FLOW (ISCM 2014), PTS 1-6, 2015, 72
  • [26] FLOW VISUALIZATION STUDY ON CENTRIFUGAL BLOOD PUMP USING A HIGH-SPEED VIDEO CAMERA
    SAKUMA, I
    TADOKORO, H
    FUKUI, Y
    DOHI, T
    ARTIFICIAL ORGANS, 1995, 19 (07) : 665 - 670
  • [27] Mechanism and prediction of inlet reverse flow onset in centrifugal pump impellers
    Huang, Jiande
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 32 (07): : 5 - 9
  • [28] Analysis of the Blood Flow Through the Centrifugal Pump
    Mikolajczak, Joanna
    Slowinski, Jakub
    Zawislak, Maciej
    PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE: COMPUTER AIDED ENGINEERING, 2017, : 375 - 382
  • [29] An automatic flow controller for a centrifugal blood pump
    Beppu, T
    Seo, K
    Imai, Y
    Takanashi, Y
    Hoshino, S
    Ohta, J
    Aoki, M
    Uchita, S
    Suzuki, S
    Tajima, Y
    Tooyama, N
    Fukui, Y
    ARTIFICIAL ORGANS, 1997, 21 (07) : 630 - 634
  • [30] The role of diastolic pump flow in centrifugal blood pump hemodynamics
    Akimoto, T
    Litwak, KN
    Yamazaki, K
    Litwak, P
    Kihara, S
    Tagusari, J
    Yamazaki, S
    Kameneva, MV
    Watach, MJ
    Umezu, M
    Tomioka, J
    Kormos, RL
    Koyanagi, T
    Griffith, BP
    ARTIFICIAL ORGANS, 2001, 25 (09) : 724 - 727