Development of a theranostic preclinical fluorescence molecular tomography/cone beam CT-guided irradiator platform

被引:4
|
作者
Nouizi, Farouk [1 ,2 ]
Brooks, Jamison [3 ]
Zuro, Darren M. [3 ]
Hui, Susanta K. [3 ]
Gulsen, Gultekin [1 ,2 ]
机构
[1] Univ Calif Irvine, Tu & Yuen Ctr Funct Oncoimaging, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Chao Family Comprehens Canc Ctr, Irvine, CA 92697 USA
[3] City Hope Natl Med Ctr, Beckman Res Inst, Dept Radiat Oncol, 1500 E Duarte Rd, Duarte, CA 91010 USA
基金
美国国家卫生研究院;
关键词
DIFFUSE OPTICAL TOMOGRAPHY; BIOLUMINESCENCE TOMOGRAPHY; X-RAY; QUANTITATIVE ACCURACY; RADIATION-THERAPY; RESOLUTION; SYSTEM; PERFORMANCE; LIGHT; MRI;
D O I
10.1364/BOE.469559
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Image-guided small animal radiation research platforms allow more precise radiation treatment. Commercially available small animal X-ray irradiators are often equipped with a CT/cone-beam CT (CBCT) component for target guidance. Besides having poor soft-tissue contrast, CBCT unfortunately cannot provide molecular information due to its low sensitivity. Hence, there are extensive efforts to incorporate a molecular imaging component besides CBCT on these radiation therapy platforms. As an extension of these efforts, here we present a theranostic fluorescence tomography/CBCT-guided irradiator platform that provides both anatomical and molecular guidance, which can overcome the limitations of stand-alone CBCT. The performance of our hybrid system is validated using both tissue-like phantoms and mice ex vivo. Both studies show that fluorescence tomography can provide much more accurate quantitative results when CBCT-derived structural information is used to constrain the inverse problem. The error in the recovered fluorescence absorbance reduces nearly 10-fold for all cases, from approximately 60% down to 6%. This is very significant since high quantitative accuracy in molecular information is crucial to the correct assessment of the changes in tumor microenvironment related to radiation therapy.
引用
收藏
页码:6100 / 6112
页数:13
相关论文
共 50 条
  • [1] Cone Beam CT-Guided Bronchoscopy Here to Stay?
    Casal, Roberto F.
    [J]. JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2018, 25 (04) : 255 - 256
  • [2] Cone Beam CT-Guided Endobronchial Biopsy Assisted by Augmented Fluoroscopy
    Pritchett, Michael
    Radaelli, Alessandro
    Schampaert, Stephanie
    van der Bom, Imramsjah
    [J]. CHEST, 2017, 152 (04) : 887A - 887A
  • [3] Cone-Beam CT-Guided Vertebroplasty in a Patient With Vertebra Plana
    Pua, Uei
    Lim, Gavin Hock Tai
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 196 - 199
  • [4] CONE-BEAM CT-GUIDED STEREOTACTIC RADIOSURGERY FOR SPINAL METASTASES
    Nguyen, Trang K.
    Wolinsky, Jean-Paul
    Sciubba, Daniel M.
    Le, Yi
    Ford, Eric
    Tryggestad, Eric
    Bydon, Ali
    Witham, Timothy F.
    Rigamonti, Daniele
    Wong, John H.
    Gokaslan, Ziya L.
    Kleinberg, Lawrence
    Lim, Michael
    [J]. NEURO-ONCOLOGY, 2009, 11 (05) : 669 - 669
  • [5] Clinical startup of cone-beam CT-guided cranial stereotactic radiotherapy
    Praestegaard, L.
    Elstrom, U. V.
    Petersen, J.
    Poulsen, P.
    Schulz, H.
    Seiersen, K.
    Traberg, A.
    Hoyer, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S289 - S290
  • [6] Cone-Beam CT-Guided Lung Biopsies: Results in 94 Patients
    Gulias-Soidan, Daniel
    Crus-Sanchez, Nilfa Milena
    Fraga-Manteiga, Daniel
    Cao-Gonzalez, Juan Ignacio
    Balboa-Barreiro, Vanesa
    Gonzalez-Martin, Cristina
    [J]. DIAGNOSTICS, 2020, 10 (12)
  • [7] A deep learning framework for prostate localization in cone beam CT-guided radiotherapy
    Liang, Xiaokun
    Zhao, Wei
    Hristov, Dimitre H.
    Buyyounouski, Mark K.
    Hancock, Steven L.
    Bagshaw, Hilary
    Zhang, Qin
    Xie, Yaoqin
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2020, 47 (09) : 4233 - 4240
  • [8] A technique for cone-beam CT-guided stereotactic body radiation therapy
    Yin, F.
    Marks, L.
    Wang, Z.
    Kirkpatrick, J.
    Wu, J.
    Yoo, S.
    Larrier, N.
    Meyer, J.
    Willett, C.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2063 - 2063
  • [9] Cone beam CT-guided navigation bronchoscopy: a cost-effective alternative to CT-guided transthoracic biopsy for diagnosis of peripheral pulmonary nodules
    Kops, Stephan E. P.
    Verhoeven, Roel L. J.
    Vermeulen, Robin J.
    Rovers, Maroeska M.
    van der Heijden, Erik H. F. M.
    Govers, Tim M.
    [J]. BMJ OPEN RESPIRATORY RESEARCH, 2022, 9 (01)
  • [10] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Nicola Rotolo
    Chiara Floridi
    Andrea Imperatori
    Federico Fontana
    Anna Maria Ierardi
    Monica Mangini
    Veronica Arlant
    Giuseppe De Marchi
    Raffaele Novario
    Lorenzo Dominioni
    Carlo Fugazzola
    Gianpaolo Carrafiello
    [J]. European Radiology, 2016, 26 : 381 - 389