PERFORMANCE EVALUATION OF COUNTER-FLOW WET COOLING TOWERS USING EXERGETIC ANALYSIS

被引:17
|
作者
Ataei, A. [1 ]
Panjeshahi, M. H. [2 ]
Gharaie, M. [3 ]
机构
[1] I Azad Univ, Grad Sch Environm & Energy, Sci & Res Branch, Dept Energy Engn, Tehran, Iran
[2] Univ Calgary, Dept Chem & Petr Engn, Calgary, AB T2N 1N4, Canada
[3] KN Toosi Univ Technol, Dept Energy Engn, Tehran, Iran
关键词
Thermal Behavior; Performance Evaluation; Simulation Modeling; Exergetic Analysis;
D O I
10.1139/tcsme-2008-0033
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, performance evaluation of wet cooling tower is done. To achieve this aim, first, thermal behavior of counter-flow wet cooling tower is studied through a simulation model. The influence of the environmental conditions on the thermal efficiency of the cooling tower is investigated. The cooling tower performance is simulated in terms of varying air and water temperatures, and of the ambient conditions. This model allows the use of a variety of packing materials. Second, the exergetic analysis is applied to study the cooling tower potential of performance improvement. The model is validated against the experimental data.
引用
收藏
页码:499 / 511
页数:13
相关论文
共 50 条
  • [31] COUNTER-FLOW EVAPORATIVE COOLING-TOWER PERFORMANCE MODELING AND VERIFICATION
    SAVERY, CW
    [J]. MECHANICAL ENGINEERING, 1976, 98 (05) : 100 - 100
  • [32] Counter-Flow Cooling Tower Test Cell
    Dvorak, Lukas
    Nozicka, Jiri
    [J]. EFM13 - EXPERIMENTAL FLUID MECHANICS 2013, 2014, 67
  • [33] Enhancing performance of wet cooling towers
    Al-Waked, Rafat
    Behnia, Masud
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (10) : 2638 - 2648
  • [34] The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
    Yuan, Wei
    Sun, Fengzhong
    Liu, Ruqing
    Chen, Xuehong
    Li, Ying
    [J]. ENERGIES, 2020, 13 (23)
  • [35] New method for computation of counter-flow cooling tower
    Zhao, Zhen-Guo
    Shi, Jin-Ling
    Zhou, Chang-Hong
    Teng, Xin-Jun
    [J]. Shuili Xuebao/Journal of Hydraulic Engineering, 2002, (02):
  • [36] Effects of Inlet Water Temperature and Heat Load on Fan Power of Counter-Flow Wet Cooling Tower
    Nguyen, Minh Phu
    Lee, Geun Sik
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2013, 37 (03) : 267 - 273
  • [37] Thermal performance of cross flow cooling towers in variable wet bulb temperature
    Hajidavalloo, Ebrahim
    Shakeri, Reza
    Mehrabian, Mozaffar A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (06) : 1298 - 1303
  • [38] Experimental investigation of the performance of a counter-flow, packed-bed mechanical cooling tower
    Bedekar, SV
    Nithiarasu, P
    Seetharamu, KN
    [J]. ENERGY, 1998, 23 (11) : 943 - 947
  • [39] COUNTER- AND CROSS-FLOW COOLING TOWERS
    MOLYNEUX, F
    [J]. CHEMICAL AND PROCESS ENGINEERING, 1967, 48 (05): : 56 - &
  • [40] COUNTER-FLOW COOLING OF A TRANSMISSION-LINE BY SUPERCRITICAL HELIUM
    MORGAN, GH
    JENSEN, JE
    [J]. CRYOGENICS, 1977, 17 (05) : 259 - 267