Rapid detection of pesticides not amenable to multi-residue methods by flow injection-tandem mass spectrometry

被引:44
|
作者
Mol, Hans G. J. [1 ]
van Dam, Ruud C. J. [1 ]
机构
[1] Wageningen Univ & Res Ctr, RIKILT Inst Food Safety, NL-6708 WB Wageningen, Netherlands
关键词
Polar pesticides; Flow-injection analysis; Tandem mass spectrometry; Screening; Food; LIQUID-CHROMATOGRAPHY; AMINOMETHYLPHOSPHONIC ACID; QUANTITATIVE-ANALYSIS; SAMPLE PREPARATION; MALEIC HYDRAZIDE; LC-MS/MS; GLYPHOSATE; CEREALS; VEGETABLES; DILUTION;
D O I
10.1007/s00216-014-7644-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow injection combined with tandem mass spectrometry (MS/MS) was investigated for the rapid detection of highly polar pesticides that are not amenable to multi-residue methods because they do not partition into organic solvents and require dedicated chromatographic conditions. The pesticides included in this study were amitrole, chlormequat, cyromazine, daminozide, diquat, ethephon, fosetyl-Al, glufosinate, glyphosate and its metabolite aminomethylphosphonic acid, maleic hydrazide, mepiquat and paraquat. The composition of the flow-injection solvent was optimized to achieve maximum MS/MS sensitivity. Instrumental limits of detection varied between < 0.05 and 1 pg. Fruit, vegetable, cereal, milk and kidney samples were extracted with water (1 % formic acid in case of paraquat/diquat) and ten times diluted in either methanol/0.1 % formic acid, methanol/0.1 % ammonia or acetonitrile/0.1 % ammonia, depending on the pesticide. The ion suppression observed depended strongly on both the matrix and the pesticide. This could be largely compensated for by matrix-matched calibration, but more accurate quantification was obtained by using isotopically labelled standards (commercially available for most of the pesticides studied). The method detection limits ranged from 0.02 mg/kg for chlormequat and mepiquat to 2 mg/kg for maleic hydrazide and were 0.05-0.2 mg/kg for most other pesticide/matrix combinations. This was sufficiently low to test compliance with EU maximum residue limits for many relevant pesticide/commodity combinations. The method substantially reduces the liquid chromatography-MS/MS capacity demand which for many laboratories is prohibitive for inclusion of these pesticides in their monitoring and surveillance programmes.
引用
收藏
页码:6817 / 6825
页数:9
相关论文
共 50 条
  • [41] Qptimization of a multi-residue method for 101 pesticides in green tea leaves using. gas chromatography-tandem mass spectrometry
    Hou, Xue
    Lei, ShaoRong
    Guo, LingAn
    Qiu, ShiTing
    REVISTA BRASILEIRA DE FARMACOGNOSIA-BRAZILIAN JOURNAL OF PHARMACOGNOSY, 2016, 26 (04): : 401 - 407
  • [42] Development and Validation of a Multi-residue Method for the Determination of Pesticides in Chios Mastic Gum by QuEChERS and Liquid Chromatography-Tandem Mass Spectrometry
    Psoma, A. K.
    Pasias, I. N.
    Bletsou, A. A.
    Thomaidis, N. S.
    FOOD ANALYTICAL METHODS, 2015, 8 (03) : 624 - 634
  • [43] SIMPLE MULTI-RESIDUE ANALYSIS OF ORGANOPHOSPHORUS PESTICIDES BY MASS CHROMATOGRAPHY
    KOBAYASHI, H
    KOJIMA, M
    MATANO, O
    GOTO, S
    JOURNAL OF PESTICIDE SCIENCE, 1979, 4 (04): : 463 - 472
  • [44] STUDY OF MULTI-RESIDUE METHODS FOR THE DETERMINATION OF SELECTED PESTICIDES IN GROUNDWATER
    HERNANDEZ, F
    BELTRAN, J
    SANCHO, JV
    SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 132 (2-3) : 297 - 312
  • [45] Rapid multi-residue screening of antibiotics in muscle and kidney by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Granelli, K.
    Branzell, C.
    ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) : 289 - 295
  • [46] Single-Laboratory Validation of a Multi-residue Method for Simultaneous Analysis of Multi-class Pesticides in Turmeric by Liquid Chromatography Tandem Mass Spectrometry
    Ghosh, Bappa
    Bhattacharyya, Arijita
    Hingmire, Sandip
    Aher, Pushpa
    Zende, Pradnya
    Banerjee, Kaushik
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (01) : 148 - 156
  • [47] Multi-residue quantitation of aminoglycoside antibiotics in kidney and meat by liquid chromatography with tandem mass spectrometry
    Ishii, R.
    Horie, M.
    Chan, W.
    MacNeil, J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2008, 25 (12): : 1509 - 1519
  • [48] Multi-residue methods for the determination of over four hundred pesticides in solid and liquid high sucrose content matrices by tandem mass spectrometry coupled with gas and liquid chromatograph
    Lozowicka, Bozena
    Ilyasova, Gulzhakhan
    Kaczynski, Piotr
    Jankowska, Magdalena
    Rutkowska, Ewa
    Hrynko, Izabela
    Mojsak, Patrycja
    Szabunko, Julia
    TALANTA, 2016, 151 : 51 - 61
  • [49] Validation of a multi-residue method and estimation of measurement uncertainty of pesticides in drinking water using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry
    Schwanz, Thiago Guilherme
    Carpilovsky, Cristiane Kohler
    Cezimbra Weis, Grazielle Castagna
    Costabeber, Ijoni Hilda
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1585 : 10 - 18
  • [50] A multi-residue method for the determination of 203 pesticides in rice paddies using gas chromatography/mass spectrometry
    Nguyen, Thanh Dong
    Han, Eun Mi
    Seo, Mi Suk
    Kim, Sa Ra
    Yun, Mi Young
    Lee, Dae Myung
    Lee, Gae-Ho
    ANALYTICA CHIMICA ACTA, 2008, 619 (01) : 67 - 74