Tetracarboxylic acid cobalt phthalocyanine SAM on gold:: Potential applications as amperometric sensor for H2O2 and fabrication of glucose biosensor

被引:101
|
作者
Mashazi, Philani N.
Ozoemena, Kenneth I.
Nyokong, Tebello
机构
[1] Rhodes Univ, Dept Chem, ZA-6140 Grahamstown, South Africa
[2] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
基金
新加坡国家研究基金会;
关键词
cobalt phthalocyanine; glucose oxidase; self-assembled monolayer; hydrogen peroxide; glucose; impedance spectroscopy;
D O I
10.1016/j.electacta.2006.04.056
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This report describes the applications of cobalt tetracarboxylic acid phthalocyanine (CoTCAPc) self-assembled monolayer (SAM) immobilized onto a preformed 2-mercaptoethanol (Au-ME) SAM on gold surface (Au-ME-CoTCAPc SAM) as a potential amperometric sensor for the detection of hydrogen peroxide (H,02) at neutral pH conditions. The Au-ME-CoTCAPc SAM sensor showed a very fast amperometric response time of approximately 1 s, good linearity at the studied concentration range of up to 5 mu M with a coefficient R-2 = 0.993 and a detection limit of 0.4 mu M oxidatively. Also reductively, the sensor exhibited a very fast amperometric response time (similar to 1 s), linearity up to 5 mu M with a coefficient R-2 = 0.986 and a detection limit of 0.2 mu M. The cobalt tetracarboxylic acid phthalocyamne self-assembled monolayer was then evaluated as a mediator for glucose oxidase (GOx)-based biosensor. The GOx (enzyme) was immobilized covalently onto Au-ME-CoTCAN SAM using coupling agents: N-ethyl-N(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS), and the results demonstrated a good catalytic behavior. Kinetic parameters associated with the enzymatic and mediator reactions were estimated using electrochemical versions of Lineweaver-Burk and Hanes equation, and the stability of the sensor was tested. The biosensor (Au-ME-CoTCAPc-GOx SAM) electrode showed good sensitivity (7.5 nA/mM) with a good detection limit of 8.4 mu M at 3 sigma, smaller Michaelis-Menten constant (4.8 mM from Hanes plot) and very fast response time of approximately 5 s. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 50 条
  • [41] Cobalt ferrite nanoparticles decorated on exfoliated graphene oxide, application for amperometric determination of NADH and H2O2
    Ensafi, Ali A.
    Alinajafi, Hossein A.
    Jafari-Asl, M.
    Rezaei, B.
    Ghazaei, F.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 : 276 - 284
  • [42] H2O2/Glucose Sensor Based on a Pyrroloquinoline Skeleton-Containing Molecule Modified Gold Cavity Array Electrode
    Wang, Kaiyue
    Gu, Xuefang
    Zhao, Qun
    Shao, Xinyi
    Xiao, Yaqi
    Zhong, Chongyu
    Tian, Shu
    Yang, Bing
    NANOMATERIALS, 2022, 12 (10)
  • [43] Nanoporous PdCu alloy as an excellent electrochemical sensor for H2O2 and glucose detection
    Yang, Hongxiao
    Wang, Zhihong
    Li, Chencan
    Xu, Caixia
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 491 : 321 - 328
  • [44] Amperometric biosensor based on reductive H2O2 detection using pentacyanoferrate-bound polymer for creatinine determination
    Nieh, Chi-Hua
    Tsujimura, Seiya
    Shirai, Osamu
    Kano, Kenji
    ANALYTICA CHIMICA ACTA, 2013, 767 : 128 - 133
  • [45] A new amperometric H2O2 biosensor based on nanocomposite films of chitosan-MWNTs, hemoglobin, and silver nanoparticles
    Li, Yancai
    Li, Yuanjun
    Yang, Yiyun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (03) : 1133 - 1140
  • [46] DETERMINATION OF ANTIOXIDANT CAPACITY USING XANTHINE-XANTHINE OXIDASE SYSTEM COUPLED WITH H2O2 AMPEROMETRIC BIOSENSOR
    Varvari, Lidia
    Lates, Vasilica
    Popescu, Ionel Catalin
    REVUE ROUMAINE DE CHIMIE, 2011, 56 (07) : 735 - 742
  • [47] Direct Electrochemistry of Catalase Immobilized at Electrochemically Reduced Graphene Oxide Modified Electrode for Amperometric H2O2 Biosensor
    Ting, Shan Wei
    Periasamy, Arun Prakash
    Chen, Shen-Ming
    Saraswathi, R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10): : 4438 - 4453
  • [48] Silver nanoparticles on graphene quantum dots as nanozyme for efficient H2O2 reduction in a glucose biosensor
    Hoang Vinh Tran
    Tuan Anh Le
    Bach Long Giang
    Piro, Benoit
    Lam Dai Tran
    MATERIALS RESEARCH EXPRESS, 2019, 6 (11)
  • [49] Fabrication of Gold Nanoparticles Modified Carbon Nanofibers/Polyaniline Electrode for H2O2 Determination
    Bao, Shiyong
    Du, Mingliang
    Zhang, Ming
    Zhu, Han
    Wang, Pan
    Yang, Tingting
    Zou, Meiling
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (12) : H816 - H821
  • [50] Convenient fabrication of graphene/gold nanoparticle aerogel as direct electrode for H2O2 sensing
    Lu, Xuan
    Liu, Xiaoli
    Shen, Ting
    Qin, Yujun
    Zhang, Pu
    Luo, Hongxia
    Guo, Zhi-Xin
    MATERIALS LETTERS, 2017, 207 : 49 - 52