Tetracarboxylic acid cobalt phthalocyanine SAM on gold:: Potential applications as amperometric sensor for H2O2 and fabrication of glucose biosensor

被引:101
|
作者
Mashazi, Philani N.
Ozoemena, Kenneth I.
Nyokong, Tebello
机构
[1] Rhodes Univ, Dept Chem, ZA-6140 Grahamstown, South Africa
[2] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
基金
新加坡国家研究基金会;
关键词
cobalt phthalocyanine; glucose oxidase; self-assembled monolayer; hydrogen peroxide; glucose; impedance spectroscopy;
D O I
10.1016/j.electacta.2006.04.056
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This report describes the applications of cobalt tetracarboxylic acid phthalocyanine (CoTCAPc) self-assembled monolayer (SAM) immobilized onto a preformed 2-mercaptoethanol (Au-ME) SAM on gold surface (Au-ME-CoTCAPc SAM) as a potential amperometric sensor for the detection of hydrogen peroxide (H,02) at neutral pH conditions. The Au-ME-CoTCAPc SAM sensor showed a very fast amperometric response time of approximately 1 s, good linearity at the studied concentration range of up to 5 mu M with a coefficient R-2 = 0.993 and a detection limit of 0.4 mu M oxidatively. Also reductively, the sensor exhibited a very fast amperometric response time (similar to 1 s), linearity up to 5 mu M with a coefficient R-2 = 0.986 and a detection limit of 0.2 mu M. The cobalt tetracarboxylic acid phthalocyamne self-assembled monolayer was then evaluated as a mediator for glucose oxidase (GOx)-based biosensor. The GOx (enzyme) was immobilized covalently onto Au-ME-CoTCAN SAM using coupling agents: N-ethyl-N(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS), and the results demonstrated a good catalytic behavior. Kinetic parameters associated with the enzymatic and mediator reactions were estimated using electrochemical versions of Lineweaver-Burk and Hanes equation, and the stability of the sensor was tested. The biosensor (Au-ME-CoTCAPc-GOx SAM) electrode showed good sensitivity (7.5 nA/mM) with a good detection limit of 8.4 mu M at 3 sigma, smaller Michaelis-Menten constant (4.8 mM from Hanes plot) and very fast response time of approximately 5 s. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 50 条
  • [1] An amperometric H2O2 biosensor based on hemoglobin nanoparticles immobilized on to a gold electrode
    Narwal, Vinay
    Yadav, Neelam
    Thakur, Manisha
    Pundir, Chandra S.
    BIOSCIENCE REPORTS, 2017, 37
  • [2] A probe for NADH and H2O2 amperometric detection at low applied potential for oxidase and dehydrogenase based biosensor applications
    Ricci, Francesco
    Amine, Aziz
    Moscone, Danila
    Palleschi, Giuseppe
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 854 - 862
  • [3] Nanoporous gold film encapsulating cytochrome c for the fabrication of a H2O2 biosensor
    Zhu, Anwei
    Tian, Yang
    Liu, Haiqing
    Luo, Yongping
    BIOMATERIALS, 2009, 30 (18) : 3183 - 3188
  • [4] A new film for the fabrication of an unmediated H2O2 biosensor
    Xu, Y
    Peng, WL
    Liu, XJ
    Li, GX
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (03): : 533 - 537
  • [5] A novel H2O2 amperometric biosensor based on gold nanoparticles/self-doped polyaniline nanofibers
    Chen, Xiaojun
    Chen, Zixuan
    Zhu, Jinwei
    Xu, Chenbin
    Yan, Wei
    Yao, Cheng
    BIOELECTROCHEMISTRY, 2011, 82 (02) : 87 - 94
  • [6] Electropolymerized film of cobalt tetrabenzimidazolephthalocyanine for the amperometric detection of H2O2
    Mohammed, Imadadulla
    Nemakal, Manjunatha
    Sajjan, Veeresh A.
    Puttappashetty, Dayananda B.
    Sannegowda, Lokesh Koodlur
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 826 : 96 - 103
  • [7] Amperometric H2O2 sensor based on gold nanoparticles/poly (celestine blue) nanohybrid film
    N. S. Sangeetha
    S. Sriman Narayanan
    SN Applied Sciences, 2019, 1
  • [8] Fabrication and application of a diamond-film glucose biosensor based on a H2O2 microarray electrode
    Wu, JL
    Zhu, JZ
    Zhang, GX
    Lin, XR
    Cheng, NY
    ANALYTICA CHIMICA ACTA, 1996, 327 (02) : 133 - 137
  • [9] Cobalt nitride nanowire array as an efficient electrochemical sensor for glucose and H2O2 detection
    Xie, Fengyu
    Cao, Xiaoqin
    Qu, Fengli
    Asiri, Abdullah M.
    Sun, Xuping
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 1254 - 1261
  • [10] Minimization of Interferences in Flow Injection Amperometric Glucose Biosensor Based on Oxidation of Enzymatically-produced H2O2
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2019, 31 (07) : 1373 - 1380