Division of the Mesoappendix with Electrocautery in Children Is Safe, Effective, and Cost-Efficient

被引:31
|
作者
Ponsky, Todd A. [1 ]
Rothenberg, Steven S. [1 ]
机构
[1] Rocky Mt Hosp Children, Dept Pediat Surg, Denver, CO USA
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | 2009年 / 19卷
关键词
LAPAROSCOPIC APPENDECTOMY;
D O I
10.1089/lap.2008.0101.supp
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Laparoscopic appendectomy is one of the most common procedures performed in children. There are several techniques available for dividing the mesoappendix including the using an endostapler, a LigaSure (Covidien, Boulder, CO), a harmonic scalpel (Ethicon Endosurgery, Cincinnati, OH), or electrocautery. Although it is the least expensive approach, many feel that electrocautery is an unsafe method of dividing the mesoappendix. Here we present our experience with the use of solely electrocautery to divide the mesoappendix. Methods: Over a period of 12 years, a total of 442 laparoscopic appendectomies were logged into our database. Each appendectomy was performed by coagulating and dividing the mesoappendix with a Maryland dissector or in some cases a hook electrocautery. Three 0-PDS Endoloops (Ethicon Endosurgery, Cincinnati, OH) were then used to ligate the base of the appendix, two proximal and one distal. Patient weight, age, operative time, perforated versus nonperforated, and intraoperative and postoperative complications were queried. Results: Of the 442 cases, 71 were perforated (16%). The mean time for nonperforated appendectomies was 26 minutes and 38 minutes for perforated. There was one case of postoperative bleeding managed nonoperatively in a patient with previously undiagnosed factor VIII deficiency. The cost of each endoloop was $22. Conclusion: Although some have questioned the safety of using electrocautery alone to divide the mesoappendix for fear that it may not be adequate to seal the appendiceal artery, may take excessive time, or may cause collateral tissue injury, this has not been our experience. Therefore, the use of more costly instruments to divide the mesoappendix such as the endostapler, LigaSure, or harmonic scalpel seems unwarranted. This study demonstrates that electrocautery for the mesoappendix and endoloops for the appendix is safe, effective, and cost-efficient.
引用
收藏
页码:S11 / S13
页数:3
相关论文
共 50 条
  • [21] COST-EFFICIENT CONVERSIONS
    ONEILL, R
    INDUSTRIAL PHOTOGRAPHY, 1984, 33 (01): : 21 - 21
  • [22] Cost-efficient designing
    Schmuck, M
    Gäbelein, J
    KUNSTSTOFFE-PLAST EUROPE, 2005, 95 (05): : 83 - 85
  • [23] Endoscopic bipolar diathermy in the management of epistaxis: an effective and cost-efficient treatment
    Ahmed, A
    Woolford, TJ
    CLINICAL OTOLARYNGOLOGY, 2003, 28 (03): : 273 - 275
  • [24] Trauma Laparoscopy: Time Efficient, Cost Effective, and Safe
    Dorricott, Alexa R.
    Dickinson, Abigail
    McNickle, Allison G.
    Batra, Kavita
    Flores, Carmen E.
    Fraser, Douglas R.
    Chestovich, Paul J.
    JOURNAL OF SURGICAL RESEARCH, 2024, 301 : 455 - 460
  • [25] Endoscopic mucosal resection for large non-pedunculated colorectal polyps: staying on track with a safe, effective and cost-efficient technique
    Mandarino, Francesco Vito
    Medas, Renato
    Gauci, Julia L.
    Kerrison, Clarence
    Whitfield, Anthony
    Gupta, Sunil
    Williams, Stephen J.
    Lee, Eric Y.
    Burgess, Nicholas G.
    Bourke, Michael J.
    GUT, 2024, 73 (10)
  • [26] Cost-efficient storage of cryogens
    Fesmire, J. E.
    Sass, J. P.
    Nagy, Z.
    Sojourner, S. J.
    Morris, D. L.
    Augustynowicz, S. D.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1383 - +
  • [27] ARE TENODESIS SPLINTS COST-EFFICIENT
    BOYER, JJ
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1990, 44 (09): : 857 - 857
  • [28] COST-EFFICIENT RECYCLING PROGRAMS
    KNAPP, B
    WORLD WASTES, 1995, 38 (06): : 22 - 22
  • [29] COST-EFFICIENT MRF DESIGN
    LINDEBERG, JD
    BIOCYCLE, 1994, 35 (08) : 66 - 69
  • [30] COST-EFFICIENT PRODUCTION OF QUALITY
    WILLE, G
    STAHL UND EISEN, 1987, 107 (12): : 573 - 574