Predictors and Prognosis of Stent Fracture After Sirolimus-Eluting Stent Implantation

被引:48
|
作者
Ino, Yasushi [2 ]
Toyoda, Yasuaki [2 ]
Tanaka, Atsushi [1 ]
Ishii, Shuuta [2 ]
Kusuyama, Yoshio [2 ]
Kubo, Takashi [1 ]
Takarada, Shigeho [1 ]
Kitabata, Hironori [1 ]
Tanimoto, Takashi [1 ]
Mizukoshi, Masato [1 ]
Imanishi, Toshio [1 ]
Akasaka, Takashi [1 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
[2] Wakayama Natl Hosp, Div Cardiol, Wakayama, Japan
关键词
Prognosis; Restenosis; Sirolimus-eluting stent; Stent fracture; CORONARY RESTENOSIS; FREQUENCY; STENOSIS;
D O I
10.1253/circj.CJ-09-0343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stent fracture is a cause of in-stent restenosis (ISR) after sirolimus-eluting stent (SES) implantation, so this study investigated the incidence. predictors and prognosis of stent fracture. Methods and Results: The 273 consecutive patients (364 lesions) after SES implantation and who had 6-9 month scheduled follow-up Coronary angiography (CAG) were divided into groups with and without stent fracture. Delta angle was defined as the difference in the angle in the target lesion between diastole and systole before the procedure. The incidence of stent fracture was 4.9% (18 of 364 lesions). Delta angle in the target lesion was larger in the fracture group (28.3 +/- 11.5 degrees vs 12.3 +/- 9.0 degrees, P<0.0001). Independent predictors of stent fracture were Delta angle and total stent length. The rates of binary restenosis and target lesion revascularization (TLR) were higher in the Fracture group (33% vs 4.0%. P=0.0002 and 28% vs 3.5%, P=0.0007, respectively). There were no major adverse cardiac events (MACE) in the fracture group during a mean 24-month follow-up after follow-up CAG. Conclusions: Predictors of stent fracture were Delta angle and total stent length. Although stent fracture was associated with ISR and TLR, it was not associated with MACE during long-term follow-up. (Circ J 2009: 73: 2036-2041)
引用
收藏
页码:2036 / 2041
页数:6
相关论文
共 50 条
  • [31] Does Sirolimus-Eluting Stent Implantation Lead to an Increased Risk of Stent Fracture?
    Umeda, Hisashi
    Gochi, Tomoko
    Iwase, Mitsuhiro
    Ishiki, Ryoji
    Inagaki, Haruo
    Izawa, Hideo
    Yokota, Mitsuhiro
    Murohara, Toyoaki
    CIRCULATION, 2008, 118 (18) : S1037 - S1038
  • [32] Repeated Sirolimus-Eluting Stent Implantation to Treat Sirolimus-Eluting Stent and Bare-Metal Stent Restenosis
    Nishihira, Kensaku
    Shibata, Yoshisato
    Ishikawa, Tetsunori
    Nomura, Katsumasa
    Nakama, Tatsuya
    Mine, Daigo
    Inoue, Yohei
    Ashikaga, Keiichi
    Kuriyama, Nehiro
    Matsuyama, Akihiko
    Imamura, Takuroh
    Asada, Yujiro
    Kitamura, Kazuo
    CIRCULATION JOURNAL, 2010, 74 (11) : 2329 - 2333
  • [33] Unique Distributions of Stent Fracture and Stent Fracture With Restenosis After Sirolimus-Eluting Stent Implanattion
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Inoue, Katsumi
    Goto, Tsuyoshi
    Fujii, Satoki
    Yamamoto, Hiroyuki
    Kato, Harumi
    Fuku, Yasushi
    Hosogi, Shingo
    Tanaka, Hiroyuki
    Habara, Seiji
    Hasegawa, Daiji
    Imai, Masao
    Ootsuru, Suguru
    Miyamoto, Masakazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A2 - A3
  • [34] Intravascular ultrasonic predictors of angiographic restenosis after sirolimus-eluting stent implantation
    Hong, MK
    Lee, CW
    Kim, YH
    Lee, BK
    Kang, DH
    Cheong, SS
    Song, JK
    Kim, JJ
    Park, SW
    Park, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 186H - 186H
  • [35] Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation
    Hong, Myeong-Ki
    Mintz, Gary S.
    Lee, Cheol Whan
    Park, Duk-Woo
    Choi, Bong-Ryong
    Park, Kyoung-Ha
    Kim, Young-Hak
    Cheong, Sang-Sig
    Song, Jae-Kwan
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    EUROPEAN HEART JOURNAL, 2006, 27 (11) : 1305 - 1310
  • [36] Predictors Of Late Target Lesion Revascularization After Sirolimus-eluting Stent Implantation
    Hara, Hironori
    Aoki, Jiro
    Hashimoto, Takuya
    Yahagi, Kazuyuki
    Lee, Laurence C.
    Nakashima, Makoto
    Nakajima, Yoshifumi
    Kishi, Satoru
    Taniwaki, Masanori
    Yachi, Sen
    Tanimoto, Shuzou
    Tanabe, Kengo
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    CIRCULATION, 2011, 124 (21)
  • [37] Incidence and predictors of stent thrombosis after paclitaxel and sirolimus-eluting stent implantation in the real world.
    Iakovou, I
    Schmidt, T
    Grube, E
    Sangiorgi, G
    Ge, L
    Chieffo, A
    Corvaja, N
    Airoldi, F
    Montorfano, M
    Michev, I
    Colombo, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 133E - 133E
  • [38] Fracture of a sirolimus-eluting stent with migration
    Kamura, Aoi
    Kawasaki, Tomohiro
    Koga, Nobuhiko
    Inoue, Teruo
    Node, Koichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 130 (02) : E86 - E88
  • [39] Impact of stent fracture after sirolimus-eluting stent implantation on 8-year clinical outcomes
    Ohya, M.
    Kadota, K.
    Habara, S.
    Tada, T.
    Tanaka, H.
    Maruo, T.
    Fuku, Y.
    Katoh, H.
    Fujii, S.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2014, 35 : 981 - 981
  • [40] Impact of stent fracture on long-term clinical outcomes after sirolimus-eluting stent implantation
    Fuku, Y.
    Kadota, K.
    Mitsudo, K.
    Goto, T.
    Oka, N.
    Tanaka, H.
    Tada, T.
    Habara, S.
    Shigemoto, Y.
    Hasegawa, D.
    EUROPEAN HEART JOURNAL, 2012, 33 : 683 - 683