Predictors and Prognosis of Stent Fracture After Sirolimus-Eluting Stent Implantation

被引:48
|
作者
Ino, Yasushi [2 ]
Toyoda, Yasuaki [2 ]
Tanaka, Atsushi [1 ]
Ishii, Shuuta [2 ]
Kusuyama, Yoshio [2 ]
Kubo, Takashi [1 ]
Takarada, Shigeho [1 ]
Kitabata, Hironori [1 ]
Tanimoto, Takashi [1 ]
Mizukoshi, Masato [1 ]
Imanishi, Toshio [1 ]
Akasaka, Takashi [1 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
[2] Wakayama Natl Hosp, Div Cardiol, Wakayama, Japan
关键词
Prognosis; Restenosis; Sirolimus-eluting stent; Stent fracture; CORONARY RESTENOSIS; FREQUENCY; STENOSIS;
D O I
10.1253/circj.CJ-09-0343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stent fracture is a cause of in-stent restenosis (ISR) after sirolimus-eluting stent (SES) implantation, so this study investigated the incidence. predictors and prognosis of stent fracture. Methods and Results: The 273 consecutive patients (364 lesions) after SES implantation and who had 6-9 month scheduled follow-up Coronary angiography (CAG) were divided into groups with and without stent fracture. Delta angle was defined as the difference in the angle in the target lesion between diastole and systole before the procedure. The incidence of stent fracture was 4.9% (18 of 364 lesions). Delta angle in the target lesion was larger in the fracture group (28.3 +/- 11.5 degrees vs 12.3 +/- 9.0 degrees, P<0.0001). Independent predictors of stent fracture were Delta angle and total stent length. The rates of binary restenosis and target lesion revascularization (TLR) were higher in the Fracture group (33% vs 4.0%. P=0.0002 and 28% vs 3.5%, P=0.0007, respectively). There were no major adverse cardiac events (MACE) in the fracture group during a mean 24-month follow-up after follow-up CAG. Conclusions: Predictors of stent fracture were Delta angle and total stent length. Although stent fracture was associated with ISR and TLR, it was not associated with MACE during long-term follow-up. (Circ J 2009: 73: 2036-2041)
引用
收藏
页码:2036 / 2041
页数:6
相关论文
共 50 条
  • [1] Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation
    Umeda, Hisashi
    Gochi, Tomoko
    Iwase, Mitsunori
    Izawa, Hideo
    Shimizu, Takeshi
    Ishiki, Ryoji
    Inagaki, Haruo
    Toyama, Junji
    Yokota, Mitsuhiro
    Murohara, Toyoaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 133 (03) : 321 - 326
  • [2] Predictors of angiographic stent fracture and stent fracture with restenosis after sirolimus-eluting stent (SES) implantation
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Goto, Tsuyoshi
    Yamamoto, Hiroyuki
    Kato, Hanumi
    Fuku, Yasushi
    Hosoki, Shingo
    Tanaka, Hiroyuki
    Yamamoto, Kanjyo
    Habara, Seiji
    Hasegawa, Daiji
    Imai, Masao
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B7 - B7
  • [3] Silent stent fracture after sirolimus-eluting stent implantation
    Ino, Yasushi
    Kubo, Takashi
    Takarada, Shigeho
    Tanimoto, Takashi
    Arida, Yu
    Kitabata, Hironori
    Kuroi, Akio
    Ueno, Satoshi
    Yomano, Takashi
    Ikejima, Hideyuki
    Tsujioka, Hiroto
    Ookouchi, Hirofumi
    Kashiwagi, Manabu
    Kataiwa, Hiderou
    Nakamura, Nobuo
    Tanaka, Atsushi
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 107L - 107L
  • [4] Incomplete stent apposition and stent fracture after sirolimus-eluting stent implantation
    Kim, Kyungheul
    Oh, Seongjin
    Kim, Byoung-Keum
    Jeon, Dong Woon
    Yang, Joo-Young
    Cho, Deok-Kyu
    Eun, Youngmin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B26 - B27
  • [5] The Timing of Occurrence of Stent Fracture After Sirolimus-eluting Stent Implantation
    Fukuzawa, Tomoyuki
    Watanabe, Takahiro
    Hanaki, Yuichi
    Seigen, I
    Aoki, Hajime
    Kato, Kenichi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : S20 - S20
  • [6] Clinical characteristics of stent fracture after sirolimus-eluting stent implantation
    Yang, Tae-Hyun
    Kim, Doo-Il
    Park, Seong-Gill
    Seo, Jeong-Sook
    Cho, Hwan-Jin
    Seol, Sang-Hoon
    Kim, Seong-Man
    Kim, Dae-Kyeong
    Kim, Dong-Soo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 131 (02) : 212 - 216
  • [7] Optimal Strategy of Restenosis with Stent Fracture after Sirolimus-eluting Stent Implantation
    Otsuro, Suguru
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Goto, Tsuyoshi
    Yamamoto, Hiyoyuki
    Fuku, Yasushi
    Hosoki, Shingo
    Tanaka, Hiroyuki
    Habara, Seiji
    Hasegawa, Daiji
    Imai, Masao
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 61D - 61D
  • [8] Is coronary stent fracture after sirolimus-eluting stent implantation an adverse event?
    Nishibori, Y.
    Fujita, H.
    Matsuo, K.
    Nakanishi, N.
    Shiono, Y.
    Yamaguchi, S.
    Matsuo, A.
    Inoue, K.
    Tanaka, T.
    Kitamura, M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (8B): : 10C - 11C
  • [9] Is coronary stent fracture after sirolimus-eluting stent implantation an adverse event?
    Nishibori, Yoshiharu
    Fujita, Hiroshi
    Matsuo, Akiko
    Shiono, Yasutsugu
    Matsuo, Kiyonari
    Nakanishi, Naohiko
    Yamaguchi, Shin-ichiro
    Inoue, Keiji
    Tanaka, Tetsuya
    Kitamura, Makoto
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B40 - B40
  • [10] In-stent restenosis after sirolimus-eluting stent implantation is related to coronary stent fracture
    Lee, S. Y.
    Kim, M. H.
    Ahn, C. M.
    Kim, J. S.
    Choi, D. H.
    Jang, Y. S.
    Chung, N. S.
    Min, P. K.
    Yoon, Y. W.
    Hong, B. K.
    CIRCULATION, 2007, 116 (16) : 467 - 468