Application of cooling water in controlled runout table cooling on hot strip mill

被引:0
|
作者
Liu, ZD [1 ]
Samarasekera, IV
机构
[1] Cent Iron & Steel Res Inst, Beijing 100081, Peoples R China
[2] Univ British Columbia, Vancouver, BC V4T 1Z4, Canada
关键词
cooling water; controlled runout table; hot strip mill;
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip. The heat of a hot steel strip is mainly extracted by cooling water during runout. In order to study the heat transfer by water jet impingement boiling during runout. a pilot facility was constructed at the University of British Columbia. On this pilot facility, the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters. Such as cooling water temperature. water jet impingement velocity. initial strip temperature, water flow rate. water nozzle diameter and array of water nozzles. on the heat transfer of heated strip. The results obtained contribute to the optimization of cooling water during runout.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 50 条
  • [21] Controlled Cooling of Strip Coils on the Conveyer of a Hot-Rolling Mill
    Chashchin V.V.
    [J]. Steel in Translation, 2018, 48 (6) : 388 - 392
  • [22] Thermal performance of numerical model of hot strip mill runout table
    Prieto, MM
    Ruíz, LS
    Menéndez, JA
    [J]. IRONMAKING & STEELMAKING, 2001, 28 (06) : 474 - 480
  • [24] MODELING THERMAL AND MICROSTRUCTURAL EVOLUTION ON RUNOUT TABLE OF HOT STRIP MILL
    KUMAR, A
    MCCULLOCH, C
    HAWBOLT, EB
    SAMARASEKERA, IV
    [J]. MATERIALS SCIENCE AND TECHNOLOGY, 1991, 7 (04) : 360 - 368
  • [25] Simulation of Runout Table Cooling
    Guemo, Gilles Guedia
    Prodanovic, Vladan
    Militzer, Matthias
    [J]. STEEL RESEARCH INTERNATIONAL, 2019, 90 (04)
  • [26] COOLING CHARACTERISTICS OF STEEL SHEET BY WATER FILM IN HOT STRIP MILL
    OTOMO, A
    YASUNAGA, S
    ISHIDA, R
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1987, 73 (08): : 996 - 1003
  • [27] IMPINGEMENT COOLING OF HOT METAL STRIPS IN RUNOUT TABLE - A REVIEW
    Mishra, Purna Ch.
    Nayak, Santosh K.
    Pradhan, Premananda
    Ghosh, Durga P.
    [J]. INTERFACIAL PHENOMENA AND HEAT TRANSFER, 2015, 3 (02) : 117 - 137
  • [28] Ultra-fast cooling on the run-out table of the hot strip mill
    Simon, P
    Fishbach, JP
    Riche, P
    [J]. REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1996, 93 (03): : 409 - &
  • [29] REDUCTION OF STRIP EDGE COOLING IN A HOT WIDE STRIP MILL
    FABIAN, W
    KOPINECK, HJ
    TAPPE, W
    WLADIKA, H
    [J]. STAHL UND EISEN, 1987, 107 (07): : 319 - 323
  • [30] DEVELOPMENT AND IMPROVEMENT OF STRIP COOLING EQUIPMENT ON HOT STRIP MILL
    TOKUSHIGE, K
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1994, 80 (03): : T52 - T55