Study of the Operational Safety of a Vascular Interventional Surgical Robotic System

被引:28
|
作者
Guo, Jian [1 ,2 ]
Jin, Xiaoliang [1 ,2 ]
Guo, Shuxiang [1 ,2 ,3 ,4 ]
机构
[1] Tianjin Univ Technol, Key Lab Control Theory & Applicat Complicated Sys, Tianjin 300384, Peoples R China
[2] Tianjin Univ Technol, Biomed Robot Lab, Tianjin 300384, Peoples R China
[3] Beijing Inst Technol, Key Lab Convergence Med Engn Syst & Healthcare Te, Inst Adv Biomed Engn Syst, Sch Life Sci,Minist Ind & Informat Technol, Beijing 100081, Peoples R China
[4] Kagawa Univ, Intelligent Mech Syst Engn Dept, Takamatsu, Kagawa 7610396, Japan
基金
中国国家自然科学基金;
关键词
vascular interventional surgery (VIS); safety early warning; master-slave tracking error; displacement error compensation algorithm; blood vessels; force feedback; FORCE FEEDBACK; DESIGN; SENSOR;
D O I
10.3390/mi9030119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper proposes an operation safety early warning system based on LabView (2014, National Instruments Corporation, Austin, TX, USA) for vascular interventional surgery (VIS) robotic system. The system not only provides intuitive visual feedback information for the surgeon, but also has a safety early warning function. It is well known that blood vessels differ in their ability to withstand stress in different age groups, therefore, the operation safety early warning system based on LabView has a vascular safety threshold function that changes in real-time, which can be oriented to different age groups of patients and a broader applicable scope. In addition, the tracing performance of the slave manipulator to the master manipulator is also an important index for operation safety. Therefore, we also transformed the slave manipulator and integrated the displacement error compensation algorithm in order to improve the tracking ability of the slave manipulator to the master manipulator and reduce master-slave tracking errors. We performed experiments "in vitro" to validate the proposed system. According to previous studies, 0.12 N is the maximum force when the blood vessel wall has been penetrated. Experimental results showed that the proposed operation safety early warning system based on LabView combined with operating force feedback can effectively avoid excessive collisions between the surgical catheter and vessel wall to avoid vascular puncture. The force feedback error of the proposed system is maintained between +/- 20 mN, which is within the allowable safety range and meets our design requirements. Therefore, the proposed system can ensure the safety of surgery.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Master-slave system research of a vascular interventional surgical robot
    Yu, H. Y.
    Wang, H. B.
    Zhang, W.
    Liu, H. Y.
    Chang, J. Y.
    Huang, D.
    [J]. PROCEEDINGS OF 2018 IEEE INTERNATIONAL CONFERENCE ON REAL-TIME COMPUTING AND ROBOTICS (IEEE RCAR), 2018, : 469 - 473
  • [32] OPERATIONAL SAFETY OF SURGICAL INSTRUMENTS
    BELLWINK.H
    [J]. CHIRURG, 1969, 40 (09): : 389 - &
  • [33] Study on the Automatic Surgical Method of the Vascular Interventional Surgical Robot Based on Deep Learning
    Guo, Jian
    Feng, Suxiang
    Guo, Shuxiang
    [J]. 2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 1076 - 1081
  • [34] Study on Force Feedback for Virtual Vascular Interventional Surgical System based on Multi-data Fusion
    Wang, Zhentao
    Guo, Jian
    Guol, Shuxiang
    Song, Yu
    [J]. PROCEEDINGS OF 2022 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2022), 2022, : 1525 - 1530
  • [35] Force Feedback-based Robotic Catheter Training System for the Vascular Interventional Surgery
    Guo, Shuxiang
    Yan, Lin
    Guo, Jian
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 2197 - 2202
  • [36] The Critical Technologies of Vascular Interventional Robotic Catheterization: A Review
    Ren, Baozhen
    Zhao, Yan
    Zhang, Jianhua
    Li, Hui
    Li, Kexiang
    Zhang, Jianjun
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (24) : 30051 - 30069
  • [37] Performance Evaluation of a Vascular Interventional Surgery Robotic System with Visual-Based Force Feedback
    Shi, Chaochao
    Ishihara, Hidenori
    [J]. MACHINES, 2023, 11 (07)
  • [38] A Novel Remote-Controlled Vascular Interventional Robotic System Based on Hollow Ultrasonic Motor
    Lu, Qing
    Sun, Zhijun
    Zhang, Jialiang
    Zhang, Jiacheng
    Zheng, Juju
    Qian, Feng
    [J]. MICROMACHINES, 2022, 13 (03)
  • [39] Study on Tracking Control of Vascular Interventional Surgical Robot based on Autocoupling PID
    Guo, Shuxiang
    Sun, Zefa
    Guo, Jian
    [J]. 2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 903 - 908
  • [40] Study of Methodologies for Risk Assessment in Operational System Safety
    Embarek, Mohamed C.
    Hadjadj, Elias A.
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2010, 10 (06) : 540 - 544