Study of the Operational Safety of a Vascular Interventional Surgical Robotic System

被引:28
|
作者
Guo, Jian [1 ,2 ]
Jin, Xiaoliang [1 ,2 ]
Guo, Shuxiang [1 ,2 ,3 ,4 ]
机构
[1] Tianjin Univ Technol, Key Lab Control Theory & Applicat Complicated Sys, Tianjin 300384, Peoples R China
[2] Tianjin Univ Technol, Biomed Robot Lab, Tianjin 300384, Peoples R China
[3] Beijing Inst Technol, Key Lab Convergence Med Engn Syst & Healthcare Te, Inst Adv Biomed Engn Syst, Sch Life Sci,Minist Ind & Informat Technol, Beijing 100081, Peoples R China
[4] Kagawa Univ, Intelligent Mech Syst Engn Dept, Takamatsu, Kagawa 7610396, Japan
基金
中国国家自然科学基金;
关键词
vascular interventional surgery (VIS); safety early warning; master-slave tracking error; displacement error compensation algorithm; blood vessels; force feedback; FORCE FEEDBACK; DESIGN; SENSOR;
D O I
10.3390/mi9030119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper proposes an operation safety early warning system based on LabView (2014, National Instruments Corporation, Austin, TX, USA) for vascular interventional surgery (VIS) robotic system. The system not only provides intuitive visual feedback information for the surgeon, but also has a safety early warning function. It is well known that blood vessels differ in their ability to withstand stress in different age groups, therefore, the operation safety early warning system based on LabView has a vascular safety threshold function that changes in real-time, which can be oriented to different age groups of patients and a broader applicable scope. In addition, the tracing performance of the slave manipulator to the master manipulator is also an important index for operation safety. Therefore, we also transformed the slave manipulator and integrated the displacement error compensation algorithm in order to improve the tracking ability of the slave manipulator to the master manipulator and reduce master-slave tracking errors. We performed experiments "in vitro" to validate the proposed system. According to previous studies, 0.12 N is the maximum force when the blood vessel wall has been penetrated. Experimental results showed that the proposed operation safety early warning system based on LabView combined with operating force feedback can effectively avoid excessive collisions between the surgical catheter and vessel wall to avoid vascular puncture. The force feedback error of the proposed system is maintained between +/- 20 mN, which is within the allowable safety range and meets our design requirements. Therefore, the proposed system can ensure the safety of surgery.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Development of a Fixture for the Vascular Interventional Surgical Robotic System
    Guo, Jian
    Shao, Xiuqiang
    Guo, Shuxiang
    [J]. 2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 307 - 312
  • [2] A Vascular Interventional Surgical Robotic System Based on Force-Visual Feedback
    Guo, Jian
    Jin, Xiaoliang
    Guo, Shuxiang
    Fu, Qiang
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (23) : 11081 - 11089
  • [3] Study on the Tracking Performance of the Vascular Interventional Surgical Robotic System Based on the Fuzzy-PID Controller
    Guo, Jian
    Jin, Xiaoliang
    Guo, Shuxiang
    Du, Wenxuan
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 29 - 34
  • [4] A Novel Path Planning Algorithm for the Vascular Interventional Surgical Robotic Doctor Training System
    Guo, Jian
    Cheng, Yuhang
    Guo, Shuxiang
    Du, Wenxuan
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 45 - 50
  • [5] Multilevel Operation Strategy of a Vascular Interventional Robot System for Surgical Safety in Teleoperation
    Bao, Xianqiang
    Guo, Shuxiang
    Guo, Yangming
    Yang, Cheng
    Shi, Liwei
    Li, Youxiang
    Jiang, Yuhua
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2022, 38 (04) : 2238 - 2250
  • [6] Study on Tracking Stability for a Master-Slave Vascular Interventional Robotic System
    Guo, Jian
    Qi, Lei
    Guo, Shuxiang
    Meng, Cheng
    Zhan, Qi
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2019, : 1387 - 1392
  • [7] Development of a Grasper for Vascular Interventional Surgery Robotic System
    Jin, Xiaoliang
    Guo, Shuxiang
    Guo, Jian
    Zhang, Linshuai
    Shi, Peng
    Song, Dapeng
    Wang, Weihao
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2019, : 2268 - 2272
  • [8] A Novel Vibrating Device for the Interventional Surgical Robotic System
    Guo, Shuxiang
    Wu, Jiaqing
    Xiao, Nan
    Zhang, Chaonan
    Zhao, Yan
    Li, Guangxuan
    Xu, Changqi
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 496 - 500
  • [9] Evaluation of a Clamping Mechanism for Vascular Interventional Surgery Robotic System
    Shi, Chaochao
    Guo, Shuxiang
    [J]. 2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 1044 - 1049
  • [10] Study on Admittance Control for the Vascular Interventional Surgical Robot
    Liao, Xianguo
    Guo, Jian
    Guo, Shuxiang
    Song, Yu
    [J]. PROCEEDINGS OF 2022 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2022), 2022, : 704 - 709