Interlaboratory comparison of melt flow rate testing of moisture sensitive plastics

被引:14
|
作者
Rides, Martin [1 ]
Allen, Crispin [1 ]
Omloo, Huub [2 ]
Nakayama, Kazuo [3 ]
Cancelli, Gianpiero [4 ]
机构
[1] Natl Phys Lab, Ind & Innovat Div, Teddington TW11 0LW, Middx, England
[2] DSM Engn Plast, NL-6160 MD Geleen, Netherlands
[3] Japan Chem Innovat Inst, High Polymer Test & Evaluat Ctr, Taito Ku, Tokyo 1110052, Japan
[4] Radici Grp, I-24024 Gandino, Italy
关键词
Melt flow rate; Plastics; MVR; MFR; Moisture sensitive;
D O I
10.1016/j.polymertesting.2009.03.013
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The current standard for melt flow rate testing, ISO 1133, does not adequately cover the measurement of materials that degrade or further polymerise at the melt flow rate test conditions. Materials such as PET, PBT and PA tend to degrade, sometimes rapidly, at melt temperatures if they contain absorbed water. This results in poor repeatability and reproducibility of melt flow rate results. The ISO Plastics Melt Rheology Working Group (TC61/SC5/WG9) is currently developing a modified melt flow rate test method for reliable measurement of moisture sensitive materials, thereby providing an alternative to intrinsic viscosity measurements. The modified method controls more tightly the time-temperature history experienced by the material during testing and, thus, the resultant variability in measured properties due to degradation. The results of an intercomparison of testing of moisture sensitive polymers using the melt volume flow rate (MVR) and melt mass flow rate (MFR) methods are reported. A polypropylene (PP), used as a benchmark material, and five moisture sensitive materials were tested by a number of laboratories measuring either MVR or MFR, or both. For standard testing of the PP material, the repeatability and reproducibility of measurements of MVR were up to 5% and 11%, respectively, and for MFR were 7% and 21%. respectively (95% confidence level, outliers excluded). For the moisture sensitive materials the repeatability and reproducibility of measurements varied significantly, with repeatability values up to 26% and reproducibility values up to 114% being obtained. By imposing moisture and temperature control criteria in accordance with the proposed testing standard, the repeatability and reproducibility limits were significantly reduced to approximately 10% and 60%, respectively. The results suggest that both the moisture and temperature criteria were important for improving the repeatability of MVR measurements. However, the moisture content criterion was more important for improving the reproducibility of MVR measurements. The need to tightly control the sample preparation, in particular the drying and subsequent sample handing procedures, and the time-temperature history of the sample throughout the test is considered critical to further improve the precision of measurements of such materials. (C) 2009 Published by Elsevier Ltd.
引用
下载
收藏
页码:572 / 591
页数:20
相关论文
共 50 条
  • [31] Interlaboratory comparison of results of susceptibility testing with caspofungin against Candida and Aspergillus species
    Odds, FC
    Motyl, M
    Andrade, R
    Bille, J
    Cantón, E
    Cuenca-Estrella, M
    Davidson, A
    Durussel, C
    Ellis, D
    Foraker, E
    Fothergill, AW
    Ghannoum, MA
    Giacobbe, RA
    Gobernado, M
    Handke, R
    Laverdière, M
    Lee-Yang, W
    Merz, WG
    Ostrosky-Zeichner, L
    Pemán, J
    Perea, S
    Perfect, JR
    Pfaller, MA
    Proia, L
    Rex, JH
    Rinaldi, MG
    Rodriguez-Tudela, JL
    Schell, WA
    Shields, C
    Sutton, DA
    Verweij, PE
    Warnock, DW
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (08) : 3475 - 3482
  • [32] Interlaboratory round robin comparison of tensile testing and the proficiency analysis of plastic indexes
    Baosteel Research Institute, Baoshan Iron and Steel Co., Ltd., Shanghai 201900, China
    Suxing Gongcheng Xuebao, 2007, 2 (1-6): : 1 - 6
  • [33] Interlaboratory comparison of testing hydraulic, elastic, and failure properties in compression: lessons learned
    Yan Cheng
    David Lockner
    Mandy Duda
    Carolyn Morrow
    Demian Saffer
    Insun Song
    Jörg Renner
    Environmental Earth Sciences, 2023, 82
  • [34] TIPS ON SELECTING THE RIGHT MELT FLOW-RATE
    MALLOY, RA
    PLASTICS WORLD, 1995, 53 (07): : 25 - 26
  • [35] Factors affecting extrudate swell and melt flow rate
    Wong, ACY
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1998, 79 (1-3) : 163 - 169
  • [36] Moisture-sensitive smart hot-melt adhesive from polyamide 6
    Masayuki Yamaguchi
    Ryo Takatani
    Yusuke Sato
    Shuichi Maeda
    SN Applied Sciences, 2020, 2
  • [37] Moisture-sensitive smart hot-melt adhesive from polyamide 6
    Yamaguchi, Masayuki
    Takatani, Ryo
    Sato, Yusuke
    Maeda, Shuichi
    SN APPLIED SCIENCES, 2020, 2 (09):
  • [38] Interlaboratory comparison of three methods for the determination of the radon exhalation rate of building materials
    de Jong, P
    van Dijk, W
    de Vries, W
    van der Graaf, ER
    Roelofs, LMM
    HEALTH PHYSICS, 2005, 88 (01): : 59 - 64
  • [39] ESIS TC4 activity on high rate testing of plastics
    Pavan, A
    ECF 12: FRACTURE FROM DEFECTS, VOLS. I-III, 1998, : 1363 - 1368
  • [40] Flow rate sensitive perfusion MR imaging in normal and ischemic brain: Comparison with ECD SPECT
    Kim, H
    Kim, D
    Jeong, EK
    Yoon, PH
    Lee, S
    Huh, Y
    RADIOLOGY, 1998, 209P : 396 - 396