Digital compared to screen-film mammography: breast cancer prognostic features in an organized screening program

被引:6
|
作者
Prummel, Maegan V. [1 ]
Done, Susan J. [2 ,3 ]
Muradali, Derek [1 ]
Majpruz, Vicky [1 ]
Brown, Patrick [1 ,3 ]
Jiang, Hedy [1 ]
Shumak, Rene S. [1 ]
Yaffe, Martin J. [4 ]
Holloway, Claire M. B. [3 ,4 ]
Chiarelli, Anna M. [1 ,3 ]
机构
[1] Canc Care Ontario, Prevent & Canc Control, Toronto, ON M5G 2L7, Canada
[2] Univ Hlth Network, Campbell Family Inst Breast Canc Res, Toronto, ON, Canada
[3] Univ Toronto, Toronto, ON, Canada
[4] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
基金
加拿大健康研究院;
关键词
Digital mammography; Computed radiography; Direct radiography; Prognostic features; Stage; Tumour size; Grade; Hormone receptor status; COMPUTED RADIOGRAPHY; PERFORMANCE-MEASURES; TRANSITION; INTERVAL; COHORTS;
D O I
10.1007/s10549-014-3088-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Our previous study found cancer detection rates were equivalent for direct radiography compared to screen-film mammography, while rates for computed radiography were significantly lower. This study compares prognostic features of invasive breast cancers by type of mammography. Approved by the University of Toronto Research Ethics Board, this study identified invasive breast cancers diagnosed among concurrent cohorts of women aged 50-74 screened by direct radiography, computed radiography, or screen-film mammography from January 1, 2008 to December 31, 2009. During the study period, 816,232 mammograms were performed on 668,418 women, and 3,323 invasive breast cancers were diagnosed. Of 2,642 eligible women contacted, 2,041 participated (77.3 %). The final sample size for analysis included 1,405 screen-detected and 418 interval cancers (diagnosed within 24 months of a negative screening mammogram). Polytomous logistic regression was performed to evaluate the association between tumour characteristics and type of mammography, and between tumour characteristics and detection method. Odds ratios (OR) and 95 % confidence intervals (CI) were recorded. Cancers detected by computed radiography compared to screen-film mammography were significantly more likely to be lymph node positive (OR 1.94, 95 %CI 1.01-3.73) and have higher stage (II:I, OR 2.14, 95 %CI 1.11-4.13 and III/IV:I, OR 2.97, 95 %CI 1.02-8.59). Compared to screen-film mammography, significantly more cancers detected by direct radiography (OR 1.64, 95 %CI 1.12-2.38) were lymph node positive. Interval cancers had worse prognostic features compared to screen-detected cancers, irrespective of mammography type. Screening with computed radiography may lead to the detection of cancers with a less favourable stage distribution compared to screen-film mammography that may reflect a delayed diagnosis. Screening programs should re-evaluate their use of computed radiography for breast screening.
引用
收藏
页码:389 / 399
页数:11
相关论文
共 50 条
  • [21] Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?
    Chantal Van Ongeval
    Andre Van Steen
    Gretel Vande Putte
    Federica Zanca
    Hilde Bosmans
    Guy Marchal
    Erik Van Limbergen
    [J]. European Radiology, 2010, 20 : 2307 - 2314
  • [22] Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?
    Van Ongeval, Chantal
    Van Steen, Andre
    Putte, Gretel Vande
    Zanca, Federica
    Bosmans, Hilde
    Marchal, Guy
    Van Limbergen, Erik
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (10) : 2307 - 2314
  • [23] Impact of a CAD system in a screen-film mammography screening program: A prospective study
    Sanchez Gomez, S.
    Torres Tabanera, M.
    Vega Bolivar, A.
    Sainz Miranda, M.
    Baroja Mazo, A.
    Ruiz Diaz, M.
    Martinez Miravete, P.
    Lag Asturiano, E.
    Munoz Cacho, P.
    Delgado Macias, T.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E317 - E321
  • [24] Screening Mammography Efficacy: A Comparison Between Screen-Film, Computed Radiography and Digital Mammography in Taiwan
    Elbakkoush, Abdallah Ahmed
    Atique, Suleman
    Chiang, I-Jen
    [J]. MEDINFO 2015: EHEALTH-ENABLED HEALTH, 2015, 216 : 914 - 914
  • [25] A comparison of clinical findings in digital and screen-film mammography
    Piccoli, CW
    Maidment, AD
    Cavanaugh, BC
    Parker, L
    Albert, M
    Cupp, SL
    [J]. RADIOLOGY, 2002, 225 : 417 - 417
  • [26] Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection
    Chiarelli, Anna M.
    Prummel, Maegan V.
    Muradali, Derek
    Shumak, Rene S.
    Majpruz, Vicky
    Brown, Patrick
    Jiang, Hedy
    Done, Susan J.
    Yaffe, Martin J.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2015, 154 (02) : 377 - 387
  • [27] DIFFERENCES IN RADIOLOGICAL PATTERNS, TUMOUR CHARACTERISTICS AND DIAGNOSTIC PRECISION BETWEEN DIGITAL MAMMOGRAPHY AND SCREEN-FILM MAMMOGRAPHY IN FOUR BREAST CANCER SCREENING PROGRAMS IN SPAIN
    Romero, A.
    Domingo, L.
    Belvis, F.
    Sanchez, M.
    Ferrer, J.
    Salas, D.
    Ibanez, J.
    Vega, A.
    Ferrer, F.
    Laso, Mas
    Macia, F.
    Castells, X.
    Sala, M.
    [J]. JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2011, 65 : A153 - A153
  • [28] Differences in radiological patterns, tumour characteristics and diagnostic precision between digital mammography and screen-film mammography in four breast cancer screening programmes in Spain
    Laia Domingo
    Anabel Romero
    Francesc Belvis
    Mar Sánchez
    Joana Ferrer
    Dolores Salas
    Josefa Ibáñez
    Alfonso Vega
    Francesc Ferrer
    M. Soledad Laso
    Francesc Macià
    Xavier Castells
    Maria Sala
    [J]. European Radiology, 2011, 21 : 2020 - 2028
  • [29] Differences in radiological patterns, tumour characteristics and diagnostic precision between digital mammography and screen-film mammography in four breast cancer screening programmes in Spain
    Domingo, Laia
    Romero, Anabel
    Belvis, Francesc
    Sanchez, Mar
    Ferrer, Joana
    Salas, Dolores
    Ibanez, Josefa
    Vega, Alfonso
    Ferrer, Francesc
    Soledad Laso, M.
    Macia, Francesc
    Castells, Xavier
    Sala, Maria
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (09) : 2020 - 2028
  • [30] Digital Compared with Screen-Film Mammography: Measures of Diagnostic Accuracy among Women Screened in the Ontario Breast Screening Program-Evidence that Direct Radiography Is Superior to Computed Radiography for Cancer Detection
    Pisano, Etta D.
    [J]. RADIOLOGY, 2016, 278 (02) : 311 - 312