Cerebrospinal Fluid Flow Dynamics in Multiple Sclerosis Patients through Phase Contrast Magnetic Resonance Imaging

被引:11
|
作者
Lagana, Maria Marcella [1 ]
Chaudhary, Anamika [2 ]
Balagurunathan, Deepa [2 ]
Utriainen, David [2 ]
Kokeny, Paul [2 ]
Feng, Wei [2 ,4 ,5 ]
Cecconi, Pietro [1 ]
Hubbard, David [3 ]
Haacke, E. Mark [2 ,4 ,5 ]
机构
[1] IRCCS Santa Maria Nascente, Fdn Don Carlo Gnocchi ONLUS, I-20148 Milan, Italy
[2] Magnet Resonance Innovat Inc, Detroit, MI 48202 USA
[3] Appl fMRI Inst, San Diego, CA 92131 USA
[4] Wayne State Univ, Dept Radiol, Detroit, MI 48201 USA
[5] Wayne State Univ, Dept Biomed Engn, Detroit, MI 48201 USA
关键词
Cerebrospinal fluid; multiple sclerosis; phase contrast mri; venous stenosis; INTERNAL JUGULAR VEINS; NORMAL-PRESSURE HYDROCEPHALUS; CEREBRAL-BLOOD-FLOW; INTRACRANIAL COMPLIANCE; VENOUS INSUFFICIENCY; NONINVASIVE MEASUREMENT; MRI; OUTFLOW; ABNORMALITIES; ARTERIAL;
D O I
10.2174/1567202611666140829161410
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We studied cerebrospinal fluid (CSF) flow dynamics at the cervical level in association with internal jugular vein (IJV) flow for 92 patients with multiple sclerosis (MS). Phase contrast magnetic resonance imaging was used to quantify flow of the CSF and major vessels (including the IJV and the carotid arteries) at the C2-C3 level in the neck. Contrast enhanced MR angiography and time-of-flight MR venography were used to subdivide MS patients into stenotic (ST) and non-stenotic (NST) populations. We evaluated: IJV flow normalized by arterial flow; CSF peaks; CSF outflow duration and its onset from systole. We tested if these variables were statistically different among different MS phenotypes and between ST and NST MS patients. The delay between the beginning of systole and the CSF outflow was higher in ST compared to NST MS. Less IJV flow was observed in ST vs NST MS. None of the measures was different between the different MS phenotypes. These results suggest that alterations of IJV morphology affect both IJV flow and CSF flow timing but not CSF flow amplitude.
引用
收藏
页码:349 / 358
页数:10
相关论文
共 50 条
  • [31] Cerebrospinal Fluid Flow Dynamics in Huntington's Disease Using Phase-Contrast Magnetic Resonance Imaging: A Pilot Cross-Sectional Study
    Rodrigues, Filipe B.
    Byrne, Lauren M.
    de Vita, Enrico
    Johnson, Eileanoir
    Scahill, Rachael
    Wild, Edward J.
    NEUROTHERAPEUTICS, 2018, 15 (01) : 261 - 262
  • [32] Four-dimensional flow magnetic resonance imaging and ultrasound assessment of cerebrospinal venous flow in multiple sclerosis patients and controls
    Schrauben, Eric M.
    Kohn, Sarah
    Macdonald, Jacob
    Johnson, Kevin M.
    Kliewer, Mark
    Frost, Sam
    Fleming, John O.
    Wieben, Oliver
    Field, Aaron
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (04): : 1483 - 1493
  • [33] CARDIAC-GATED PHASE-CONTRAST MAGNETIC RESONANCE IMAGING OF CEREBROSPINAL FLUID FLOW IN THE DIAGNOSIS OF IDIOPATHIC SYRINGOMYELIA COMMENTS
    Benzel, Edward C.
    Traynelis, Vincent C.
    Zee, Chi-Shing
    NEUROSURGERY, 2008, 63 (06) : 1144 - 1144
  • [34] Analysis of aqueductal cerebrospinal fluid flow after endoscopic aqueductoplasty by using cine phase-contrast magnetic resonance imaging
    Schroeder, HWS
    Schweim, C
    Schweim, KH
    Gaab, MR
    JOURNAL OF NEUROSURGERY, 2000, 93 (02) : 237 - 244
  • [35] Cerebrospinal Fluid Dynamics in Patients with Multiple Sclerosis: The Role of Phase-Contrast MRI in the Differential Diagnosis of Active and Chronic Disease
    Oner, Serkan
    Kahraman, Aysegul Sagir
    Ozcan, Cemal
    Ozdemir, Zeynep Maras
    Unlu, Serkan
    Kamisli, Ozden
    Oner, Zulal
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 72 - 78
  • [36] MULTIPLE-SCLEROSIS - CORRELATION OF MAGNETIC-RESONANCE IMAGING WITH CEREBROSPINAL-FLUID FINDINGS - REPLY
    HONIG
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1989, 52 (01): : 145 - 145
  • [37] DEMONSTRATION OF PULSATILE CEREBROSPINAL-FLUID FLOW USING MAGNETIC-RESONANCE PHASE IMAGING
    RIDGWAY, JP
    TURNBULL, LW
    SMITH, MA
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (713): : 423 - 427
  • [38] Magnetic Resonance Imaging Cerebrospinal Fluid Hydrodynamics in Patients with Meningitis
    Lakhera, Devkant
    Azad, Rajiv Kumar
    Azad, Sheenam
    Singh, Ragini
    Sharma, Rohitash
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [39] Cerebrospinal fluid dynamics and relation with blood flow -: A magnetic resonance study with semiautomated cerebrospinal fluid segmentation
    Balédent, O
    Henry-Feugeas, MCC
    Idy-Peretti, I
    INVESTIGATIVE RADIOLOGY, 2001, 36 (07) : 368 - 377
  • [40] Cine cerebrospinal fluid imaging in multiple sclerosis
    Magnano, Christopher
    Schirda, Claudiu
    Weinstock-Guttman, Bianca
    Wack, David S.
    Lindzen, Eric
    Hojnacki, David
    Bergsland, Niels
    Kennedy, Cheryl
    Belov, Pavel
    Dwyer, Michael G.
    Poloni, Guy U.
    Beggs, Clive B.
    Zivadinov, Robert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (04) : 825 - 834