Comparison Between Vacuum Sublimed Matrices and Conventional Dried Droplet Preparation in MALDI-TOF Mass Spectrometry

被引:58
|
作者
Jaskolla, Thorsten W. [1 ]
Karas, Michael [1 ]
Roth, Udo [2 ]
Steinert, Kerstin [2 ]
Menzel, Christoph [2 ]
Reihs, Karsten [3 ]
机构
[1] Univ Frankfurt, Inst Pharmaceut Chem, Cluster Excellence Macromol Complexes, D-60438 Frankfurt, Germany
[2] Qiagen GmbH, Hilden, Germany
[3] AMF GmbH, Cologne, Germany
关键词
ASSISTED-LASER-DESORPTION/IONIZATION; INITIAL-ION VELOCITY; DESORPTION-IONIZATION; DEPOSITION INTERFACE; SAMPLE PREPARATION; INTERNAL ENERGY; ORGANIC-SOLIDS; DEPENDENCE; ABLATION; MECHANISMS;
D O I
10.1016/j.jasms.2009.02.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The properties of several cinnamic acid compounds used as matrices for matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) were investigated as standard dried droplet (DD) and vacuum sublimed preparations. The differences between both preparation methods were analyzed with regard to matrix grain size, internal ion energy, initial velocity, analyte intensity, and analyte incorporation depth. Some of the used cinnamic acid derivatives exhibit clearly reduced grain sizes as sublimed preparations compared with standard DD approaches. In these cases higher effective temperatures could be measured accompanied by increased analyte intensities, which can be explained by stronger volatilization processes caused by a hindered heat dissipation resulting in a raised analyte transfer into the gas phase. For all sublimed compounds, a strong increase of the initial ion velocity compared with DD preparations could be measured. Higher initial ion velocities correlate with a decrease in internal ion energy which might be attributed to the very uniform crystal morphology exhibited by sublimed compounds. For sublimed matrices without reduced grain size, at least slightly higher analyte intensities could be detected at raised laser fluences. Analyte accumulation in the uppermost matrix layers or the detected higher ion stability can be explanations for these results. (J Am Soc Mass Spectrom 2009, 20, 1104-1114) (C) 2009 American Society for Mass Spectrometry
引用
收藏
页码:1104 / 1114
页数:11
相关论文
共 50 条
  • [21] Performance of MALDI-TOF Mass Spectrometry in the Philippines
    Osa, Morichika
    Belo, Maria Cecilia
    Dela Merced, Zita
    Villanueva, Annavi Marie G.
    Mauhay, Jaira
    Celis, Alyannah
    Catli, Melissa
    Suzuki, Shuichi
    Ukawa, Tatsuya
    Tamaki, Shingo
    Dhoubhadel, Bhim Gopal
    Ariyoshi, Koya
    Telan, Elizabeth Freda O.
    Umipig, Dorcas Valencia
    Parry, Christopher M.
    Saito, Nobu
    Smith, Chris
    TROPICAL MEDICINE AND INFECTIOUS DISEASE, 2021, 6 (03)
  • [22] Analysis of peptides by MALDI-TOF mass spectrometry
    Sedo, O
    Havel, J
    CHEMICKE LISTY, 2003, 97 (02): : 109 - 113
  • [23] Analysis of phytosterol by MALDI-TOF mass spectrometry
    Li, Yueyan
    Liang, Miao
    Shu, Jinian
    Zhang, Peng
    Sun, Wanqi
    ANALYTICAL METHODS, 2014, 6 (13) : 4754 - 4760
  • [24] Identification of dermatophytes by MALDI-TOF mass spectrometry
    De Respinis, S.
    Pranghofer, S.
    Tonolla, M.
    Altwegg, M.
    Petrini, O.
    Bosshard, P. P.
    MYCOSES, 2012, 55 : 271 - 271
  • [25] MALDI-TOF mass spectrometry and bacterial taxonomy
    Lay, JO
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (08) : 507 - 516
  • [26] MALDI-TOF mass spectrometry moves forward
    Constans, A
    SCIENTIST, 2003, 17 (06): : 42 - 42
  • [27] Fish Authentication by MALDI-TOF Mass Spectrometry
    Mazzeo, Maria Fiorella
    De Giulio, Beatrice
    Guerriero, Giulia
    Ciarcia, Gaetano
    Malorni, Antonio
    Russo, Gian Luigi
    Siciliano, Rosa Anna
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (23) : 11071 - 11076
  • [28] Detection of melanochromes by MALDI-TOF mass spectrometry
    Kroesche, C
    Peter, MG
    TETRAHEDRON, 1996, 52 (11) : 3947 - 3952
  • [29] MALDI-TOF mass spectrometry, an emerging technology for filamentous fungi identification in comparison with conventional method in UMMC
    Arumugam, K.
    Nadzri, S. H. Mohamad
    Singh, H. K. Lakhbeer
    Velayuthan, R. D.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 101 : 194 - 194
  • [30] Effects of humidity on the dried-droplet sample preparation for MALDI-TOF MS peptide profiling
    Umemura, Hiroshi
    Kodera, Yoshio
    Nomura, Fumio
    CLINICA CHIMICA ACTA, 2010, 411 (23-24) : 2109 - 2111