Heartbeat Detection by Laser Doppler Vibrometry and Machine Learning

被引:17
|
作者
Antognoli, Luca [1 ]
Moccia, Sara [2 ,3 ]
Migliorelli, Lucia [2 ]
Casaccia, Sara [1 ]
Scalise, Lorenzo [1 ]
Frontoni, Emanuele [2 ]
机构
[1] Univ Politecn Marche, Dept Ind Engn & Math Sci, I-60121 Ancona, Italy
[2] Univ Politecn Marche, Dept Informat Engn, I-60121 Ancona, Italy
[3] Ist Italiano Tecnol, Dept Adv Robot, Genoa, Italy
关键词
laser doppler vibrometry; machine learning; support vector machines; contactless measurements; heartbeat; heart rate detection; CAROTID-ARTERY; NONCONTACT APPROACH; CLASSIFICATION; VALIDATION; EXTRACTION; PRESSURE; DIAMETER; SYSTEM; SENSOR; TIME;
D O I
10.3390/s20185362
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Heartbeat detection is a crucial step in several clinical fields. Laser Doppler Vibrometer (LDV) is a promising non-contact measurement for heartbeat detection. The aim of this work is to assess whether machine learning can be used for detecting heartbeat from the carotid LDV signal. Methods: The performances of Support Vector Machine (SVM), Decision Tree (DT), Random Forest (RF) and K-Nearest Neighbor (KNN) were compared using the leave-one-subject-out cross-validation as the testing protocol in an LDV dataset collected from 28 subjects. The classification was conducted on LDV signal windows, which were labeled as beat, if containing a beat, or no-beat, otherwise. The labeling procedure was performed using electrocardiography as the gold standard. Results: For the beat class, the f1-score (f1) values were 0.93, 0.93, 0.95, 0.96 for RF, DT, KNN and SVM, respectively. No statistical differences were found between the classifiers. When testing the SVM on the full-length (10 min long) LDV signals, to simulate a real-world application, we achieved a median macro-f1 of 0.76. Conclusions: Using machine learning for heartbeat detection from carotid LDV signals showed encouraging results, representing a promising step in the field of contactless cardiovascular signal analysis.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 50 条
  • [21] Laser Doppler Vibrometry Measurement of the Mechanical Myogram
    Rohrbaugh, John W.
    Sirevaag, Erik J.
    Richter, Edward J.
    10TH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER AND NONCONTACT TECHNIQUES - AIVELA 2012, 2012, 1457 : 266 - 274
  • [22] Editorial special issue on "Laser Doppler vibrometry"
    Vanlanduit, Steve
    Dirckx, Joris
    OPTICS AND LASERS IN ENGINEERING, 2017, 99 : 1 - 2
  • [23] Laser Doppler vibrometry measurement of the mechanical myogram
    Rohrbaugh, John W.
    Sirevaag, Erik J.
    Richter, Edward J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (12):
  • [24] Laser Doppler vibrometry with acoustooptic frequency shift
    Kaczmarek, PR
    Rogowski, T
    Antonczak, AJ
    Abramski, KM
    OPTICA APPLICATA, 2004, 34 (03) : 373 - 384
  • [25] Abnormality Detection Method from Heartbeat Sound by Machine Learning
    Itsuki, Shimomoto
    Hironori, Uchida
    Nakatoh, Yoshihisa
    Li, Yujie
    Digest of Technical Papers - IEEE International Conference on Consumer Electronics, 2024, : 180 - 184
  • [26] Detection of heartbeat abnormalities from phonocardiography using machine learning
    Omarov, Batyrkhan
    Gamry, Khaled
    Batyrbekov, Aidar
    Alimzhanova, Zhanna
    Dauytova, Zhamila
    Seitbekova, Gulzhan
    2021 11TH INTERNATIONAL CONFERENCE ON CLOUD COMPUTING, DATA SCIENCE & ENGINEERING (CONFLUENCE 2021), 2021, : 843 - 847
  • [27] Heartbeat Detection with Doppler Sensor Using Adaptive Scale Factor Selection on Learning
    Mogi, Eriko
    Ohtsuki, Tomoaki
    2015 IEEE 26TH ANNUAL INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR, AND MOBILE RADIO COMMUNICATIONS (PIMRC), 2015, : 2166 - 2170
  • [28] Electromechanical response of polymer films by laser Doppler vibrometry
    Guillot, FM
    Jarzynski, J
    Balizer, E
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (03): : 1421 - 1427
  • [29] Exploiting Laser Doppler Vibrometry in Large Displacement Tests
    Copertaro, E.
    Chiariotti, P.
    Martarelli, M.
    Castellini, P.
    ROTATING MACHINERY, VIBRO-ACOUSTICS & LASER VIBROMETRY, VOL 7, 2019, : 199 - 205
  • [30] Primary accelerometer calibration by scanning laser Doppler vibrometry
    Sprecher, Daniel
    Hof, Christian
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (06)