Experimental study of radiation efficiency from an ingested source inside a human body model

被引:0
|
作者
Chan, Yawen [1 ]
Meng, Max Q. -H. [1 ]
Wu, K. -L. [1 ]
Wang, Xiaona [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The attenuation of human body trunk at frequency range. of 100MHz to 6GHz from an internal source was estimated using a simplified experimental model. Antennas were placed in the model which was filled with distilled water, 0.9% NaCl saline solution, and porcine body tissue alternately to determine the attenuation of the system. Saline has greater attenuation than water due to its higher conductivity, while porcine body tissue has attenuation hounded by saline solution and water. Estimated attenuation at the four ISM bands, 434MHz, 915MHz, 2.45GHz and 5.8GHz were given and all of these bands satisfied the safety and sensitivity requirements of a biomedical telemetry system. 915MHz and 2.45GHz are good choices for the wireless link because of their relatively larger electrical size of RF components such as antenna. In addition, with the growth in wireless LAN and Bluetooth technology, miniaturized antennas, camera modules, and other RF devices have been developed which can be employed in biomedical ingested or implanted devices. This paper gives a reference of attenuation values of a human body trunk of average size. It should be noted that the attenuation values can be different for different body size and different body composition, and therefore the values in this paper serves as a reference only.
引用
收藏
页码:7754 / 7757
页数:4
相关论文
共 50 条
  • [11] ADMITTANCE AND RADIATION EFFICIENCY OF HUMAN BODY IN RESONANCE REGION
    ANDERSEN, JB
    BALLING, P
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1972, 60 (07): : 900 - &
  • [12] RADIATION EFFICIENCY AND THE GAIN OF A SOURCE INSIDE A 2-LAYERED GROUNDED DIELECTRIC STRUCTURE
    BHATTACHARYYA, AK
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1992, 5 (09) : 439 - 441
  • [13] DETUNING STUDY OF IMPLANTABLE ANTENNAS INSIDE THE HUMAN BODY
    Vidal, N.
    Curto, S.
    Lopez Villegas, J. M.
    Sieiro, J.
    Ramos, F. M.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2012, 124 : 265 - 283
  • [14] Efficiency evaluation model on the damage of radiation source by Anti-Radiation UAV
    Dai Huan-Yao
    Jiang Hong-Yu
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 1333 - 1338
  • [15] Model Device for Detection of Narcotics Transported Inside Human Body
    L. N. Erofeev
    E. B. Fel'dman
    B. A. Shumm
    V. P. Tarasov
    V. A. Zabrodin
    Applied Magnetic Resonance, 2007, 32 : 293 - 302
  • [16] Model device for detection of narcotics transported inside human body
    Erofeev, L. N.
    Fel'dman, E. B.
    Shumm, B. A.
    Tarasov, V. P.
    Zabrodin, V. A.
    APPLIED MAGNETIC RESONANCE, 2007, 32 (03) : 293 - 302
  • [17] Electromagnetic radiation from ingested sources in the human intestine at the frequency of 2.4 GHz
    Xu, L. S.
    Meng, Max Q. -H.
    Ren, H. L.
    PIERS 2008 HANGZHOU: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, VOLS I AND II, PROCEEDINGS, 2008, : 893 - 897
  • [18] EFFICIENCY OF A BODY-RADIATION SPECTROMETER WHEN THERE IS A NONUNIFORM ISOTOPIC DISTRIBUTION IN SOURCE
    PAVLOV, SY
    YUZGIN, VS
    SOVIET ATOMIC ENERGY-USSR, 1970, 28 (03): : 328 - &
  • [19] Efficiency of Nonpoint Source Pollution Instruments: An Experimental Study
    François Cochard
    Marc Willinger
    Anastasios Xepapadeas
    Environmental and Resource Economics, 2005, 30 : 393 - 422
  • [20] Efficiency of nonpoint source pollution instruments: An experimental study
    Cochard, F
    Willinger, M
    Xepapadeas, A
    ENVIRONMENTAL & RESOURCE ECONOMICS, 2005, 30 (04): : 393 - 422