Calibration and validation methods for DOAS remote sensing systems

被引:0
|
作者
Margelli, F [1 ]
Giovanelli, G [1 ]
机构
[1] CNR, ISAC, Bologna Sect, I-00185 Rome, Italy
来源
AIR POLLUTION X | 2002年 / 11卷
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work presents a methodology, based on comprehensive measurements performed in the laboratory using an optical cell with fixed geometrical path (I m), for the calibration and validation of a remote sensing system used in air quality analysis and control. The method was tested on a DOAS (Differential Optical Absorption Spectroscopy) system produced by "Kayser-Italia", but is applicable to other equivalent remote sensors. In the laboratory it was possible to simulate atmospheric depth in the range of 1-500 ppmm, modulating the gas concentration inside an optical cell. To verify the gas calibration curve of the spectrometer, a measurement set of different gas optical paths inside the cell were used. The variation of cell gas concentration was obtained by means of a vacuum pump, starting from an initial filling of the cell using a cylinder mixture of the examined gas with N-2. The accurate value of the gas concentration was inferred from pressure measurement inside the cell. This procedure gives good results for SO2 and NO2 calibration test; for O-3 the calibration procedure is almost the same but there's the necessity of producing the gas during measurement itself. In the case of compounds with relatively high vapour pressures (such as aromatics), which are liquid at standard atmospheric pressure, the above-described measurements were preceded by an evaporation phase at low pressure (about 1-5 mb). This method makes it possible to obtain precise gas calibration curves, based on several points in the complete working span, by means of a single mixture cylinder or pure compound, The results are reliable and repetitive and the method is also applicable in field measurements. Six gases were analysed (SO2, NO2, O-3, Benzene, Toluene, Xylene) and their calibration curves and ACS (Absolute Cross Section) are presented.
引用
收藏
页码:381 / 390
页数:10
相关论文
共 50 条
  • [21] Calibration and Validation of SWAT Model by Using Hydrological Remote Sensing Observables in the Lake Chad Basin
    Bennour, Ali
    Jia, Li
    Menenti, Massimo
    Zheng, Chaolei
    Zeng, Yelong
    Barnieh, Beatrice Asenso
    Jiang, Min
    REMOTE SENSING, 2022, 14 (06)
  • [22] Evaluation of in situ radiometric data processing for calibration and validation of satellite ocean color remote sensing
    Naik, Puneeta
    Wang, Menghua
    OCEAN SENSING AND MONITORING VI, 2014, 9111
  • [23] Validation of Calibration Methods at NMIs
    Eduarda Filipe
    Measurement Techniques, 2003, 46 : 415 - 420
  • [24] Remote Sensing of Autumn Phenology by Including Surface Soil Temperature: Algorithm Development, Calibration, and Validation
    Yuan, Huanhuan
    Wang, Xiaoyue
    Jassal, Rachhpal S.
    Lu, Linlin
    Peng, Jie
    Wu, Chaoyang
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2022, 15 : 6485 - 6494
  • [25] Validation of calibration methods at NMIs
    Filipe, E
    MEASUREMENT TECHNIQUES, 2003, 46 (04) : 415 - 420
  • [26] Calibration/validation methods for GRACE
    Jekeli, C
    GEODESY BEYOND 2000: THE CHALLENGES OF THE FIRST DECADE, 2000, 121 : 83 - 88
  • [27] Remote sensing of on-road motor vehicle emissions by DOAS and TDLAS techniques
    Liu, JG
    Liu, WQ
    Dong, FZ
    Xie, PH
    Zhang, YJ
    Wei, QN
    OPTICAL TECHNOLOGIES FOR ATMOSPHERIC, OCEAN, AND ENVIRONMENTAL STUDIES, PTS 1 AND 2, 2005, 5832 : 74 - 82
  • [28] Field methods in remote sensing
    Zhu, Honglei
    GEOGRAPHICAL REVIEW, 2007, 97 (04) : 577 - 578
  • [29] Field methods in remote sensing
    Forsythe, K. Wayne
    CANADIAN GEOGRAPHER-GEOGRAPHE CANADIEN, 2006, 50 (04): : 527 - 528
  • [30] Remote Sensing and Advanced GIS: New Sensor Systems, Innovative Methods
    Tavares Junior, Stelio Soares
    REVISTA ACTA GEOGRAFICA, 2007, 1 (01): : 127 - 128